This document is a Performance Work Statement (PWS) for the USS Miguel Keith (ESB 5) Reverse Osmosis Unit Troubleshoot and Repair contract (SSU25-003). The PWS describes the requirement for Aqua Chem to provide a field service technical representative to program, test, and troubleshoot the reverse osmosis unit for approximately 3 days. The contractor is required to identify any failed components, provide a detailed report, utilize available spare parts, demonstrate operational procedures, and furnish necessary tools and test equipment. The deliverables include a memory module with the pre-loaded program, a CPU module, and a salinity/conductivity transmitter. The performance period is September 11-11, 2024, and the location is the USS Miguel Keith in Guam. The Technical Points of Contact are provided, including the Service Manager, Government Representatives, and Ship's Force contacts. This PWS is related to the federal contract opportunity N4044625Q0001, a solicitation for the SSU25-003 contract issued by the Department of the Navy Military Sealift Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N4044625Q0001.pdf | ||
| Use of Other than Full and Open for SAT_MGK REV1_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PEFORMANCE WORK STATEMENT
USS MIGUEL KEITH
Title: REVERSE OSMOSIS UNIT TROUBLESHOOT & REPAIR
Contract: SSU25-003
1.0 SCOPE OF WORK:
1.1 This performance work statement describes the requirement for Aqua Chem Reverse Osmosis Unit
Repairs.
1.2 References: See enclosures below.
2.0 SPECIFIC TASKS:
2.1 Upon this task order:
2.1.1 Provide the services of one (1) field service technical representative to program, test, troubleshoot aqua chem reverse osmosis unit for approximately 3 days.
2.1.2 For Estimating Purposes: The Contractor shall provide OEM required tools, materials, computers, software, and configuration files to troubleshoot, test and possibly repair system components with travel to Guam. If there are any spares parts available prior to technician travel request parts be carried with the service technician that may have been determined via distance support.
2.1.3 Contractor shall identify all failed components and provide a detailed report to ships force. Utilize any spare parts that are onboard to assist in repair that may be available to ships force.
2.1.4 Contractor shall demonstrate normal (if possible) as well as emergency / manual operational procedures with ships force and discuss all requirements to operate the unit in the emergency / manual mode of operation.
2.1.5 Provide ships force with a copy of the logic testing program if available to the PLC program computer for future troubleshooting and repair.
2.1.6 Contractor shall furnish all tools and test equipment that will be required to perform the repairs and testing.
2.1.7 The ship will be underway at the start of the period of performance therefor the
Service Rep will be helo out to the ship.
3.0 DELIVERABLES:
3.1 The contractor shall provide the following deliverables:
3.1.1 Memory Module with the program pre-loaded
3.1.2 CPU module
3.1.3 Salinity/conductivity transmitter
3.2 Contractor shall provide completed condition and service report for the reverse osmosis system.
4.0 PERFORMANCE LOCATION:
USS Miguel Keith (ESB 5) Guam
5.0 PERFORMANCE PERIOD:
09 – 11 OCT 2024
6.0 TECHNICAL POINT OF CONTACT:
Carl McMillan Service Manager cmcmillan@aqua-chem.com
Jim Cravens Cell: (757) 705-9395 Email: james.w.cravens.civ@us.navy.mil
Benjamin Cost T-ESB Type Desk Office (757) 341-7657 Cell: (757) 943-7941 Email: Benjamin.t.cost.civ@us.navy.mil
Ed Madrelino Cell: (671) 480-8085 Office: (671) 339-6040 Email: edwin.s.madrelino.civ@us.navy.mil
7.0 ADDITIONAL INFORMATION: Distance Support was utilized.
mailto:Benjamin.t.cost.civ@us.navy.mil
We have had some trouble with our RO System. It started when the Emergency Stop was pushed while running In Normal Mode. The PT109 stopped working and the Salinity Sensor Stopped Working. After Troubleshooting We found the PT109 was shorted NC. Once you took, one of the leads off, the Salinity Sensor came back and we received a Conductivity High Error. We cannot clear the error or run the RO in Manual Mode. We had a Gentleman (service Tech from Aqua-chem Inc.) came out and look at the Programming on the PLC, and made some changes so we could run it in Manual Mode. He made sure according to him made once we receive, the new PT109 We could resort back to the Normal mode. We successfully ran the RO in Manual for about 3-weeks without a hitch. Today we received the PT109 Sensor. We shut down the system. Installed the new PT109. Switch to Normal and booted up the RO. The attached picture you can see the Pressure is back for the PT109 but the Salinity Sensor went out! We are receiving some PLC errors (see attached) and a new weird error Alarm time Acknowledge Message (see attached).
Tried to revert to the Manual Mode, shut down the system, disconnect the PT109, switch to Manual and boot back up. Same thing happened from before. No Salinity sensor, same errors. Now we reverted to day one.RO is not working in either mode, Normal/Manual. We did get a copy of the program before changes were made and after changes were made to run in Manual. We do not have the Application software to download it back into the PLC.
Request the field service technician to return and re program the PLC
Enclosure 1
Enclosure 2
Enclosure 3
Enclosure 4