SOW.pdf
PDF 19 MB Posted
- Attached to
- Window and Door Replacement, CAPE HATTERAS NATIONA Federal contract opportunity
- Solicitation number
- 140P5324R0040
About this file
The document is a Statement of Work (SOW) for a federal contract opportunity to provide window and door replacement services at the Cape Hatteras National Seashore. The contract is a Firm-Fixed Price 100% Small Business Set-Aside, to be awarded to the lowest priced technically acceptable quote. The NAICS code is 321911 Window and Door Manufacturing, with a size standard of 1,000 employees. The estimated magnitude of the requirement is between $100,000 and $250,000, with a period of performance of 120 days from the notice to proceed, approximately September 10, 2024 to January 9, 2024. An optional site visit is scheduled for August 13, 2024, and the deadline for vendor questions is August 16, 2024. Quotes are due by September 6, 2024. The contracting agency is the Department of the Interior National Park Service Southeast Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P5324R0040_Amd_0001.pdf | ||
| Questions_and_Answers_0001.pdf | ||
| Wage_Rate_Determination.pdf | ||
| Past_Performance_Questionnaire.pdf | ||
| Sol_140P5324R0040.pdf | ||
| Construction_Contract_Administration.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Replace windows and doors on the HI Bookstore and Comfort Station Page 1
CAPE HATTERAS NATIONAL SEASHORE
Outer Banks Group
Statement of Work
Replace windows and doors at the Hatteras Island bookstore and comfort Station
1.0 INTRODUCTION
The National Park Service (NPS) will be contracting the replacement of the windows and doors for Hatteras Island Bookstore and Comfort Station. The construction site the Hatteras Island Bookstore, and the Comfort Station located at 46375 Lighthouse Rd, Buxton, NC 27920
2.0 BACKGROUND AND EXISTING CONDITIONS:
The Hatteras Island Bookstore and the comfort Station were built in 2000 of wood framing, wood pile foundation, T1-11 siding, composite doors. The Bookstore is 50 ft x 61 ft and the comfort station is 35 ft x 42 ft and are single story. The windows and door are showing signs of aging and heavy use and need replacement. The addition of ADA/ABA automatic openers to the main entrance to the bookstore and to the family restroom is required as well.
3.0 SCOPE OF WORK
The contractor shall provide all technical support, materials, tools, equipment, and labor required to complete the replacement of the windows and doors for the bookstore and the comfort station.
The contractor must verify all existing conditions, measurements, dimensions, etc. This scope of work provides observed or measured information on site, but the Contractor is responsible for correctly and accurately understanding the existing conditions.
Replace windows and doors on the HI Bookstore and Comfort Station Page 2
The Contractor is responsible for ensuring the proposed products will mount correctly and, in the space, provided in each restroom. The International Building Code and applicable Federal, State, and Local laws and codes will be enforced.
Major project components: Contractor must field verify all measurements, measurements given are approximate.
BOOKSTORE:
1. Remove and replace these existing windows: 5@ 36x40 casement and 9@ 15x33 Awning. Windows are to be double pane, hurricane impact resistant glass with multi pane grid work. Replace all interior and exterior trim.
2. Remove and replace, in-kind, Existing main entrance door 72x80 and install automatic opener with 2 remote activation switches, 1 interior and 1 exterior. Doors are to have double pane, hurricane impact resistant glass and all required hardware for use and operation. Replace all interior and exterior trim.
3. Remove and replace rear steel exit door 36x 80 Replace all interior and exterior trim.
Doors are to include all required hardware for use and operation.
4. Remove and discard the installed hurricane shutters.
COMFORT STATION:
5. Remove and replace 4@36x80 steel exterior doors on 3 restrooms and 1 plumbing chase, an automatic opener with 2 remote activation switches, 1 interior and 1 exterior will be installed on the family restroom door. Replace all interior and exterior trim. Doors are to include all required hardware for use and operation.
6. Remove and replace 13 @15x33 Awning windows and 1@20x48 frosted glass fixed pane window. Windows are to be double pane, hurricane impact resistant glass with multi pane grid work. Replace all interior and exterior trim.
7. Remove and discard the installed hurricane shutters.
Replace windows and doors on the HI Bookstore and Comfort Station Page 3