This is a Statement of Work (SOW) for the repair and restoration of a Shimadzu MALDI TOF mass spectrometry instrument located at Bartlett Hall, Building 753, Department of Chemical and Biological Science and Engineering. The instrument, serial number 60509/09, is non-functional and requires four specific replacement parts: Axima ACP Viewing Optics Assembly upgrade kit, DSP control PCB (replacing AE4433AB) with Launchpad 2.9.8 or higher, Service/Spares ACP PC Kit Z2G9 (with monitor), and a new Transient recorder PCB. All parts must be new and factory certified with no used components acceptable. The contract covers both parts and labor during the period of performance, with a pre-contract survey already completed by technicians who have confirmed the repairs are achievable based on attached quotes.

The primary task requires the contractor to inspect, repair, and replace parts as necessary to restore the MALDI TOF to its original performance specifications and design capabilities, with no loss of functionality acceptable following repair. Upon completion, the technician must conduct a thorough examination and provide a verbal report documenting all repair actions taken, ensuring all original functionality is restored and operational in the presence of a department laboratory technician or supervisor. The related federal contract opportunity (Solicitation W911SDQA106) indicates the government is conducting market research for this sole-source repair service contract with the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis, with authority under 10 U.S.C. 2304(c)(1).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bartlett Hall, Bldg 753, Shimadzu MALDI TOF Instrument Department of Chemical and Biological Science and Engineering at 753 Cullum Road owns a Shimadzu MADI TOF (serial number 60509/09). The instrument is non-functional due to four faults. The instrument needs four replacement parts: Axima ACP Viewing Optics Assembly upgrade kit, DSP control PCB (replaces AE4433AB) Launchpad 2.9.8 or higher required, Service/Spares ACP PC Kit Z2G9 (With Monitor), Transient recorder PCB – new.

Parts and Labor covered during the period of performance. All parts will be new, factory certified – no used parts.

Pre-Contract Survey (PCS). Technician(s) have inspected the equipment and using best judgement believe that the repairs can be accomplished as outlined in attached quotes.

Tasks

a. Inspect/repair/replace parts as needed to allow the MALDI TOF to reach performance as set forth when originally purchased and as expected to achieve when designed. No loss in capability is acceptable after repair.

Following the repair, the technician(s) will issue a verbal report summarizing what actions were taken to repair the MALDI TOF. The technician will conduct a thorough examination of the MALDI TOF and ensure that all functionality is restored and works as originally intended with a department laboratory technician or supervisor present.