This statement of work describes greenhouse gas emission research requiring continuous supply of high-purity support gases and calibration gases. The objective is to quantify total area- and yield-scaled emissions of N2O, CO2, and CH4 from irrigated row crops using vented chambers and gas chromatography. Analyses will measure atmospheric gas concentrations in experimental fields weekly throughout the rice growing cycle. Ultra-high-purity helium, zero-grade air, P5, and hydrogen gases are needed to continuously operate the GC2014 and GC2030 instruments, along with standard certified special blend calibration gases to calibrate the systems. Table 1 summarizes the description, frequency of usage, frequency of tank return, and number and duration of tank rentals needed for carrier and calibration gases to analyze CO2, N2O and CH4 emissions annually. Deliverables are high-quality greenhouse gas emissions datasets ensuring repeatability and lowest coefficient of variance within calibration ranges during span calibration.
The related federal contract opportunity is a blanket purchase agreement for rental of gas cylinders and gases to support greenhouse gas emission research.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TITLE:
Quantification of greenhouse gas emissions from irrigated drill seeded systems
OBJECTIVE:
1. To quantify total area- and yield-scaled N2O, CO2, and CH4 emissions from row crop fields using vented chamber method and fully automated gas chromatography system.
APPROACH:
The regular purchase of high-quality special blend and carrier gases is crucial to support research projects on greenhouse gas emissions (GHG) from row crops. The vented flux chamber method coupled with gas chromatography will be used to quantify emissions of CO2, N2O, and CH4 from soil trace gas collected at weekly intervals throughout rice crop cycle in various experimental fields. Analyses of atmospheric gases such as CO2, N2O and CH4 concentrations will be conducted using the GC2014 and GC2030 automated gas chromatography (GC) systems equipped with ECD, FID, TCD detectors. Ultra-high-quality helium, zero-grade air gas, P5 and hydrogen gases in 300 and 200 tank sizes with 99.999% purity will be used to continuously run the GC. Standard certified special blend of gases are also needed to calibrate the GC instruments. Table 1 summarizes the description and frequency of support gases and calibration gases needed for the analyses of CO2, N2O and CH4 throughout the rice crop cycle (annual measurements).
Table 1. Summary of carrier gases and calibration gases needed to analyze atmospheric gases from experimental fields.
| Atmospheric gas |
| Tank size |
| Description |
| Frequency of usage |
| Frequency of tank return |
| Number of tank rental and duration |
| Helium |
| 300 |
| Ultra-high purity Helium |
| 2 tanks per two weeks |
| 2 tanks per two weeks |
| 2 tanks per two weeks |
| P5 |
| 300 |
| 95% Argon and 5% CH4 |
| 1 tank per 6 mons |
| 1 tank per 6 mons |
| 1 tank per 6 mons |
| Hydrogen |
| 200 |
| Industrial grade Hydrogen gas |
| 1 tank per 6 mons |
| 1 tank per 6 mons |
| 1 tank per 6 mons |
| Zero-grade air |
| 300 |
| Ultra-high purity compressed air |
| 2 tanks per two weeks |
| 2 tanks per two weeks |
| 2 tanks per two weeks |
| Calibration gas 1 |
| 200 |
| 0.318 ppm N2O, 2.0 ppm CH4, 400 ppm CO2 balanced in N2 gas |
| 1 tank per 2 years |
| 1 tank per 2 years |
| 1 tank per 2 years |
| Calibration gas 2 |
| 200 |
| 10 ppm CH4 |
| 1 tank per 2 years |
| 1 tank per 2 years |
| 1 tank per 2 years |
| Calibration gas 3 |
| 200 |
| 1 ppm N2O, 100 ppm CH4, 1,000 ppm CO2 balanced in N2 gas |
| 1 tank per 5 years |
| 1 tank per 5 years |
| 1 tank per 5 years |
| Calibration gas 4 |
| 200 |
| 3 ppm N2O, 500 ppm CH4, 10,000 ppm CO2 balanced in N2 gas |
| 1 tank per 5 years |
| 1 tank per 5 years |
| 1 tank per 5 years |
Continuous supply of high-purity support gases and high accuracy calibration gases from the same source ensure the high quality GHG emission datasets. The same high purity gases are needed to maintain the high sensitivity and accuracy of GC detections from all three detectors.
DELIVERABLES:
This work provides high quality GHG emissions with minimum error of estimates from chamber method and GC instrument. It ensures high repeatability and the lowest coefficient of variance within each range of calibration gases and during span calibration.