SOW Compliance Matrix.pdf
PDF 44 KB Posted
- Attached to
- Ink Tackmeter Federal contract opportunity
- Solicitation number
- 2031ZA21Q00224
About this file
This document outlines requirements for a federal solicitation seeking three ink tackmeters. The Bureau of Engraving and Printing requires new three-roller tackmeters to measure the physical and rheological properties of various inks and materials used in currency and security printing. One tackmeter must test conventional non-UV inks with bottom rubber, central temperature-controlled metal, and top rubber rollers. A second must test UV inks with bottom polymeric, central temperature-controlled metal, and top polymeric rollers. Both must precisely measure tack in units from 0-600 and set time in seconds, with roller temperatures from 15-60 degrees Celsius. The tackmeters, cooling/heating systems, and software must be delivered and installed with automatic tool recognition, configuration, and dimensions suitable for benchtop use. The selected vendor will provide warranty, calibration certification, training, and meet performance requirements for durability, dimensions, voltage standards, and safety.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Alternate Combined Synopsis for Ink Tackmeter June 22nd 2021.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOW Requirements for New Ink
Tackmeter(s) Checklist for Vendor to Complete
Can meet requirement?
Yes or No Comments
3.0 Equipment delivered meet all current U.S.
commercial codes and industrial standards
4.0 TECHNICAL REQUIREMENTS/SPECIFIC
TASKS
4.2 Measure apparent tack in tack units (TU)
4.3 Measure tack in tack units (TU)
4.4 Measure initial tack in tack units (TU)
4.5 Measure maximum tack in tack units (TU)
4.6 Measure Set-time in seconds
4.7 Tack Range: 0 – 600 Tack Units
4.8 Rollers Speed: 50 – 350 meters/minute
4.9
For three Ink Tackmeters - Contain three rollers for conventional inks: bottom elastomer (“rubber”) oscillating distribution roller, central metal roller (temperature controlled by water bath or equivalent), and Top elastomer (“rubber”) roller connected to measuring system
4.1 0
For one Ink Tackmeter Contain - three rollers for UV Inks: Bottom elastomer (“polymeric”) oscillating distribution roller, Central metal temperature controlled by Water Bath or equivalent), and Top elastomer (“polymeric”) roller connected to measuring system
4.11 Roller temperature: range 15 to 60 o C ± 0.1 o C
4.12 Cooling/heating systems: required to operate the instrument must be included with the instrument and installation
4.13 Construction: durable and sturdy
4.14 Dimensions: compact suitable for standard
lab benchtop use.
4.15 Voltage: Standard US compliant
4.16 Operation: Automatic tool recognition and
intelligent configuration system
4.17 Software
4.18 Unit Delivery and Equipment Installation
4.19 Certificate of Calibration
5.0 Warranty
6.0 Bureau Acceptance Test (BAT) and
Training
7.0 Period of Performance
8.0 Place of Performance
9.0 Deliverables
10.0 Performance Required
11.0 Safety
File details come from the government source that posted it. Updated .