This document outlines the specifications for a Commercial Hybrid Solar Inverter 30K. Key details include that the inverter can support up to 39,000 watts of PV input power and deliver 30,000 watts of power to battery and AC outputs. It has 4 MPPT inputs, supports 120V/208V three phase AC connections, includes integrated safety certifications and protections, and has a wall mounted NEMA 3R enclosure.
The related federal contract opportunity is solicitation number 12405B23Q0531 for a Commercial Hybrid Solar Inverter 30K from the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery. The specifications document provides the product requirements for this solicitation.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Commercial Solar Hybrid Inverter 30K – Specifications
1- Max PV power 39000 watts 2- Max PV Power Delivered to Battery & AC Outputs 30,000W 3- Max DC Voltage (Voc) 500V @ 36A 4- MPPT Voltage 150 V 5- Number of MPPT 4 6- Max AC Coupled Input into the GEN terminal (micro / string inverters) 54kW w/no PV dc / 30kVA w/39 kW PV dc 7- Max DC current per MPPT (self limiting) 36A 8- AC Connections 120V / 208V Three Phase 9- Continuous AC Power with PV 30,000W 83.4 A (208V) 10- Continuous AC Power from Batteries 30,000W 83.4 A (208V) 11- Parallel Stacking YES up to 12 12- Frecuency 60/50 Hz 13- Continuous AC Power with Grid or Generator 72,000W 200A L-L (208V) / 36,000W 200A L-N (120V) 14- Electronics Certified Safety by TÜV Rheinland to NEC & UL Specs 15- Grid Sell Back — UL 1741-2021 3rd Edion (incl UL1741SB), CSA C22.2, IEEE 1547-2018 & 1547a-2020 & 1547.1-2020, UL1699B Arc- Fault Circuit-protection Type 1 16- PV DC Disconnect Switch — NEC 240.15 INTEGRATED 17- Ground Fault Detection — NEC 690.5 INTEGRATED 18- PV Rapid Shutdown Control — NEC 690.12 INTEGRATED 19- PV Arc Fault Detection — NEC 690.11 INTEGRATED 20- PV Input Lightning Protecon INTEGRATED 21- PV String Input Reverse Polarity Protection INTEGRATED 22- Surge Protection DC Type II / AC Type II 23- Wi-Fi & LAN Communication Included 24- Nominal DC input >300V 25- Capacity 50 – 9900Ah 26- Installation Wall Mounted 27- Enclosure IP65 / NEMA 3R