This is a Statement of Work for repair and service of a breathing air system located at Joint Base Charleston, South Carolina. The contractor shall perform equipment services on Gardner Denver VS50 Breathing Air Compressors and DBS205 Breathing Air Dryer/Purifiers located in Building 515 at the Corrosion Control Facility. The scope includes replacing four compressor coolers (two each for compressor number one and two each for compressor number two) and providing preventative maintenance on compressor number two only.

The contractor must supply all supervision, labor, materials, tools, and equipment necessary to complete the work. Specific deliverables include four compressor coolers (VS-50 NON-OEM P/N Gl 00007946), a 4000-hour maintenance kit (KCK4210), a 4000-hour maintenance kit (GDBS205), two MLS3903 cartridges, two filter elements (6526), and all necessary assembly hardware including bolts, nuts, cleaners, sealants, and expendables. The coolers must meet minimum specifications including dimensions of 35" x 29.25" x 6 rows with copper tubing (0.50OD x 0.016), aluminum fins (0.006), galvanized steel-flanged casing, and copper connections. The contractor shall be completely mobile and self-contained, including management and disposal of industrial and hazardous waste. All work must be performed by qualified and certified mechanics. Operations occur Monday through Friday from 6:30 AM to 5:00 PM, and the contractor must implement a commercial quality control program to ensure services meet contract requirements.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

REPAIR AND SERVICE OF BREATHING AIR SYSTEM

437TH MXS, Bldg 515

JOINT BASE CHARLESTON, SC

27 April 2026

GENERAL REQUIREMENTS:

1.1. This Statement of Work (SOW) is designed to define the expectations and deliverables for those that will assist the 437th MXS on Joint Base Charleston (JB CHS) - Air Base (AB), SC, for repair and modification on the following equipment for the items below.

The Contractor shall be completely mobile and self-contained to include industrial/hazardous waste management, clean-up and disposal. All repairs and modifications shall be performed using qualified/certified mechanics experienced with the equipment listed below:

SCOPE OF WORK:

2.1. The Contractor shall perform equipment services, including repair and service on the required equipment associated with the Breathing Air System located in Building 515 on Joint Base Charleston, SC (JB CHS). The required service and repairs will be performed on the existing Gardner Denver VS50 Breathing Air Compressors and DBS205 Breathing Air Dryer/Purifiers. The location of the Air Compressors is in the Corrosion Control Facility. The replacement of coolers will be two (2) each for the number one compressor and two (2) each for the number two compressor, for a total of four (4) coolers being replaced.

Preventative maintenance will only be required on compressor number two. The Contractor shall provide all supervision, labor, materials, tools, and equipment to carry out all work and operations as necessary.

2.2. The Contractor shall perform equipment services: Including removal of existing equipment, purchase, installation, and modification of new equipment:

2.2.1. Replace Coolers and Service of the Gardner Denver Breathing Air Compressor Model # VS50:

• Four Compressor Coolers VS-50 NON-OEM P/N Gl 00007946

• 4000 Hr KCK4210 Maintenance Kit

• 4000 Hr GDBS205 Maintenance Kit

• 2 each MLS3903 Cartridges

• 2 each Filter Elements 6526

• All necessary assembly hardware shall be provided by contractor. Including all required bolts, nuts, miscellaneous, materials, cleaners, sealants and expendables.

GENERAL INFORMATION:

3.1. 437 MXS hours of operation are 6:30AM to 5:00PM Monday thru Friday, unless otherwise notified by the Aircraft Structural supervisor.

QUALITY CONTROL:

4.1. The contractor shall employ a commercial quality control program and procedures to identify, prevent and ensure non-reoccurrence of defective services.

Through implementation of the contractor’s Quality Control Program and procedures, the Government shall receive quality services meeting the requirements of the contract.

SPECIFICATIONS:

5.1. At a minimum the coolers shall possess the following specifications:

• EnviroAIre VS50 G1000007946R Non-OEM water cooler or equal items must possess the following minimum salient characteristics:

• 35” X 29.25” X 6 rows

• Tubing = 0.50OD X 0.016 Copper

• Fins= .006 Aluminum

• Casing=Galvanized Steel-Flanged

• Conn=Copper