This is a Statement of Work (SOW) for Bioness SCI (Spinal Cord Injury) Therapies in support of a Department of Veterans Affairs Veterans Health Administration procurement. The SOW outlines the delivery and implementation of Bioness wireless therapy systems, specifically the H200 and L300 product lines, which are functional electrical stimulation devices designed to assist patients with lower extremity mobility and rehabilitation. The required products include multiple L300 GO System units configured for left and right lower leg applications, left and right thigh plus configurations, a clinician kit, two clinician programmers, foot sensors, and H200 wireless system components including clinician programmers and various wireless system kits for bilateral lower extremity applications. The procurement is being conducted through Veterans Integrated Service Network 16 as a brand name or equal solicitation, indicating that while Bioness products are specified, equivalent alternatives may be considered. The underlying federal contract opportunity (Solicitation Number 36C25626Q0857) was issued as a pre-solicitation Sources Sought Notice to identify potential vendors and define the procurement strategy, with the VA planning to issue a formal solicitation shortly thereafter. Interested parties were instructed to monitor the Federal Contract Opportunities website and GSA for updates regarding timeline, specific response requirements, and award details.

View the file

Other files

File Type Posted
RFI - 36C25626Q0857.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

Bioness H200 and L300 Wireless Integrated Therapy System Purpose: The Michael E. Debakey VA Medical Center (MEDVAMC) is requesting to purchase replacement parts for the Bioness H200 and L300 Wireless Integrated Therapy Systems. The current equipment has reached the end of life expectancy and usefulness. This procurement will be beneficial the Occupational Therapy outpatient and Spinal Cord Injury Therapy clinics to better serve our Veterans and their needs for therapy.

Catalog/part Number
Item Description
Quantity
LG4-5100
L300 GO SYSTEM, LEFT LOWER LEG
1
LG4-5000
L300 GO SYSTEM, RIGHT LOWER LEG
1
L4P-5001
L300 GO SYSTEM, LEFT THIGH PLUS
1
L4P-5100
L300 GO SYSTEM, RIGHT THIGH PLUS
1
LG4-4000
L300 GO CLINICIAN KIT
1
LG4-4200
L300 GO CLINICAN PROGRAMMER
2
LG4-5400
L300 GO, FOOT SENSOR-REGULAR
2
H2W-4800
H200 WIRELESS CLINICAN PROGRAMMER
2
H2W-5200
H200 WIRELESS SYSTEM KIT, LEFT (MEDIUM)
1
H2W-5400
H200 WIRELESS SYSTEM KIT, LEFT (LARGE)
1
H2W-5500
H200 WIRELESS SYSTEM KIT, RIGHT (LARGE)
1
H2W-5300
H200 WIRELESS SYSTEM KIT, RIGHT (MEDIUM)
1

Scope:

The Bioness (nerve stimulators) helps patients regain functions due to central nervous system disorders and orthopedic injuries. Devices could have the ability to increase range of motion and reduce the risk of falls, while improving confidence and independence.

Performance Monitoring:

N/A Security Requirements:

There are no security requirements the purchase of the needed rehabilitative equipment.

Place of Performance MEDVAMC Rehabilitation Occupational Therapy Clinic in the Spinal Cord Injury Nursing Units.