Exhibit – A Project Location
45.50n.s.f.97.20n.s.f.92.66n.s.f.
309.40n.s.f.
120.59n.s.f. 134.74n.s.f.98.30n.s.f.
SUBCOMPACT PARKING
UP
AREAWAY
STAIR
#1
AREAWAY
ELEC.
EQUIPMENT
AREAWAY
FD
FD
PARKING
ENTRANCE
EMERG.
DISTRIBUTION
UP
#6
STAIR
UP
AREAWAY
FD
SUBCOMPACT PARKING
UP
STOR.
BF102
BG103
BF100
BF100
B
BF109
STORAGE
LIGHT BULBS & EQUIP.
#5
STAIR
#3STAIR
BG110STORAGECARPENTRY
BG111ELECTRIC SHOPSTORAGE
BG112STORAGEBIOMEDICAL SHOP
STORAGE
INTERIOR DESIGN
BG114
AREAWAY
FD
AREAWAY
FD
2516.20n.s.f.
544.64n.s.f.
206.00n.s.f.
87.50n.s.f.
635.10n.s.f.
328.90n.s.f.
320.50n.s.f.
319.60n.s.f.
AREAWAY
884.00n.s.f.
BF110
STORAGE
MULTI
BF111
407.00n.s.f.
MULTI
STORAGE
AREAWAY
OPEN TO
ABOVE
AREAWAY
#8A
DN
STAIR
CHILLER
#9A
STAIR
DN
A.H.U.
DN.
STAIR #10
ENGINEERING
CORRIDOR
CORRIDOR
SUBCOMPACT PARKING
CORRIDOR
H.A.C.
TRASHFD
COLLECT
SIG.
ELEC.
LINEN
COLLECT
SIG.
ELEC.
MECHANICAL
PUMP ROOM
CORRIDOR
MECHANICALOXYGEN
STORAGE
BATTERY
P-1P-3
A.H.U.
CORRIDOR
LOBBY
AREAWAY
AREAWAY
CHARGING
ELEC.
EQUIPMENT
AREAWAY
FD
FD
PARKING
ENTRANCE
EMERG.
DISTRIBUTION
UP
#6
STAIR
UP
AREAWAY
FD
SUBCOMPACT PARKING
STOR.
BG103
BF100
BE128
BE125
CB-4
BE124a
BE123
BE121
BE122
CB-10
BE102
BE100
BE101
CB-2
CB-6
BE118
CB-11
BF100
B
CONTROL CENTER
A/C SHOP
BE124
ROOM
BE119
BF109
STORAGE
LIGHT BULBS & EQUIP.
#5
STAIR
CLOS.
BG110STORAGECARPENTRY
BG111ELECTRIC SHOPSTORAGE
OFFICE
CHIEF
BE119b
BE119c
& DINING AREA
KITCHEN
ROOM
S.P.D.
AREAWAY
FD
AREAWAY
FD
SIDEWALK
SIDEWALK
ROOM
6" 6"
6"
AREAWAY
BE123a
STORAGE
BF110
STORAGE
MULTI
BF111
MULTI
STORAGE
STORAGE
UP
UP
S-1 S-2 S-3
DN UP
UP
STAIR
DN
#7A
CREDIT
UNION
PLUMBING & HVAC SHOP
#9
STAIR
DN
A.H.U.
DN.
STAIR #10
ENGINEERING
BE118
CONTROL CENTER
A/C SHOP
BE119
OFFICE
BE127
BE128
OFFICE
BE131 BE132
OFFICE
CHIEF
BE119b
BE119c
& DINING AREA
KITCHEN
PURCHASING AGENTS
STORAGE
PROSTHETICS REPS
DIRECTOR
WAITING/FILES AREA
RECEPTION PURCHASING
AGENTS
SUPERVISOR
787 SF
0082.016Tilche Pedestal Lavatory 8"C WHT American Standard Inc.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE0000
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
RAMP DN.
FIXT_CODEFU_TOTALFU_WASTEFU_HOTFU_COLDFIXT_CODEFU_TOTALFU_WASTEFU_HOTFU_COLD
CREDIT
UNION
ASIDASCOLORASNAMEASCATNO
OPEN TO
ABOVE
UP
AREAWAY
#8
DN
STAIR
PLUMBING & HVAC SHOP
#9
STAIR
DN
A.H.U.
DN.
STAIR #10
ENGINEERING
CORRIDOR
CORRIDOR
STAIR
#2
S-3S-2
CORRIDOR
FUTURE
ELEV.
MACHINE
S-1
H.A.C.
TRASHFD
COLLECT
SIG.
ELEC.
LINEN
COLLECT
SIG.
ELEC.
MECHANICAL
PUMP ROOM
#4
STAIR
CORRIDOR
UP
MECHANICALOXYGEN
STORAGE
BATTERY
FUTURE
p-1
P-2
DN. UP
P-3
CORRIDOR
LOBBY
CHARGING
BE125
CB-4
BE124a
BE123
BE121
BE122
CB-10
BE102
BE105
BE100
BE101
CB-2
CB-6
BE118
CB-11
CONTROL CENTER
A/C SHOP
BE124
ROOM
BE119
AGENT
BE127
BE132
CLOS.
OFFICE
CHIEF
BE119b
BE119c
& DINING AREA
KITCHEN
S.P.D.
1648.40n.s.f.
80.00n.s.f.
80.00n.s.f.
449.50n.s.f.331.00n.s.f.
1135.80n.s.f.
102.20n.s.f.
144.50n.s.f.
5276.20n.s.f.
62.50n.s.f.
745.40n.s.f.
891.30 n.s.f.
172.10n.s.f.
281.70n.s.f.
48.00n.s.f.
155.80n.s.f.
139.10n.s.f.
BE123a
429.60n.s.f.
STORAGE
REPRESENTATIVE
PROSTHETICS
DIRECTOR
STORAGE
PURCHASING
AGENTS
SUPERVISOR
787 SF
159.84n.s.f.
155.47n.s.f.
257.58 n.s.f.
0082.016Tilche Pedestal Lavatory 8"C WHT American Standard Inc.
1580.00n.s.f.
GIP WAREHOUSE
OFFICE
63.00n.s.f.
BE118b
BE118c
ATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
0000 OFFICE
OFFICE0000
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
RAMP DN.
FIXT_CODEFU_TOTALFU_WASTEFU_HOTFU_COLDFIXT_CODEFU_TOTALFU_WASTEFU_HOTFU_COLD
257.08n.s.f. 231.71n.s.f.
244.03n.s.f. 394.45n.s.f. 383.65 n.s.f.
800 n.s.f.
138.80n.s.f.
85.70n.s.f.
85.70n.s.f.
1320.35n.s.f.
85.70n.s.f.
49n.s.f.
49n.s.f.
184n.s.f.
184n.s.f.
OFFICE
OFFICE
OFFICE
OFFICE
PURCHASING
AGENT
PROSTHETICS
PURCHASING
CHIEF OF
WAITING AREA
OFFICE
STORAGE
OFFICE STAFF
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
TREATMENT
ROOM OFFICE
UP
BATH
MECHANICALMECHANICALMECHANICAL
MIS.
ASSIT
MED.
RECD.
SUPERVISOR
CORRIDOR
SEC. SUPRV. SUPRV.
CHIEF CH.
BE111
BE113 BE114
BE110
BE115
BE112
97.20n.s.f.92.66n.s.f.
309.40n.s.f.
120.59n.s.f. 134.74n.s.f.98.30n.s.f.
NEW PHARMACY ADMINISTRATIVE OFFICES
1 2 3 4 5
BATH.
TRANSCRIPTION
SUPV.
PHYS.
WORK
BE107
BE109
BE108
BE106
424.33n.s.f.
90.30n.s.f.
680.32n.s.f.
47.20n.s.f.
CODING OPD
CODING OPD
ELEV.
MACHINE
CB013LADIES
6 7
1,997 n.s.f.
MEN'S
WAITING
11 12 13109
16 17 18 19 20
4'-3"
6'-111 2"
5'-8"
21 22 23 24
25 26 28 29
6'-1"
6'-1"
3'-61 2"
5'
4'-6"
4'-6" 1'-2"
2'-3"
4'-41 2"
3'-11"
ELEV.
MACHINE
CB013LADIES
MEN'S
WAITING
NEW PHARMACY ADMINISTRATIVE OFFICES
CORRIDOR CORRIDOR
FILE
1,997 n.s.f.
REF.
ASSISTANCE
CHIEF
SERVICE
CHIEF
REF.
PRINTER
COPY
CLINICAL
COORDINATOR
PV PAYMENT
PROGRAM COORDINATOR
FILE
FILE
FILE
WAITING
AREA
STORAGE
COPYRECEPTION
CLERK
FILE
PACT
PHARMATECH
SUPERVISOR
SUPERVISOR
RESEARCH
COORDINATOR
FILE FILE
FILE FILE
ADPAC'S
& EDUCATION
REF.
FILE
CONFERENCE
3'-9"
2'-51 4"
3'-6"
4'-13 8"
SECRETARY
3'-10"
REF.
FILE
3'-03 8"
3'-61 8"
3'-81 4"
STORAGE
ACCESS TO
ADMIN BLDG
OFFICES
4380dgsf
1,220
2,100
This area will be for patient pick-up. Five parking spaces will be designated exclusively to picking up patients from the new ambulatory clinic. The A/E must plan and design this area for such purposes. The design must include floor slab, seating area, green area, and coverage from weather conditions (some sort of roof), among others. This area must be aesthetically pleasing and in harmony with the surrounding buildings.
This area has been designated for the construction of the new ambulatory clinic. In the event that we need to increase the footprint to meet the project requirements, the vehicular entrance of the parking cannot be lost or obstructed. In such case, the footprint increase should be done in a way that does not compromise the entrance.
In this area, the facility has electrical, mechanical, and storage rooms that serve OPA building.
Access to those rooms cannot be lost, limited or compromised due to this project. The A/E must take this into consideration and design functional access to those rooms. This access will be used for maintenance, repairs or replacement of the equipment in those rooms. Therefore, the access must be wide enough, uninterrupted and lead to the outside of the building effortlessly.
CONNECTION OF THE NEW AMBULATORY
CLINIC WITH THE OPA BUILDING
LEGEND
AutoCAD SHX Text
*SPACE NOT FOUND**SPACE NOT FOUND**SPACE NOT FOUND*
AutoCAD SHX Text
*SPACE NOT FOUND**SPACE NOT FOUND**SPACE NOT FOUND*
AutoCAD SHX Text
*SPACE NOT FOUND**SPACE NOT FOUND**SPACE NOT FOUND*B
AutoCAD SHX Text
*SPACE NOT FOUND**SPACE NOT FOUND**SPACE NOT FOUND*B
Exhibit – B Preliminary Space Program
Program for Design (5 PROCEDURES, NO CHANGE/DRESSING ROOM)
Functional Area Room Room Code Qty Area Net Area Comments
1 SUPPORT AREA Alcove, Clean Linen LCCL1 [[SC467]] 1 40 40 ok
2 SUPPORT AREA Alcove, Wheelchair SRLW1 [[SB252]] 1 40 40
3 SUPPORT AREA Housekeeping Aides Closet
(HAC)
JANC1 1 60 60
4 SUPPORT AREA medication room MEDP1 [[SV583]] 1 80 80
5 SUPPORT AREA Storage, Equipment [[240 S.F.
Between 6 & 10
[[CGE61]] 1 240 240 c-arms, fluroscopies stored after use
6 SUPPORT AREA Storage_instruments, Sterile [[2 X 80 for 6 to 10 rooms}}
SRS04 [[CGE56]] 1 80 80 updated to ONE as for FIVE procedure rooms. Update to TWO if SIX P. Rooms.
SUPPORT AREA EHRM/OIT ROOM ?? 1 100 100 ADDED, per conversation with Zoltan, was not on
SEPS
7 SUPPORT AREA Utility Room, Clean [120 S.F.
between 6 & 10 P. Rooms]
UCCL1 [[SB737]] 1 120 120
8 SUPPORT AREA Utility Room, Soiled [100 S.F.
between 6 & 10 P. Rooms]
USCL1 [[SB743]] 1 100 100
1 SPS SPS_Decontamination Room, Scope
USCL2 [[CGE41]] 1 120 120
2 SPS SPS_Reprocessing Room, Scope
USCL3 [[CGE46]] 1 120 120
3 SPS SPS_Anteroom disinfection 1 100 100 Ver SPS guides 60 +60 ppe
4 SPS SPS_Anteroom sterilization 1 100 100 Ver soil room
5 SPS SPS_Storage, Clean Scope [[80 S.F. for 6 to 10 rooms]]
USCL4 [[CGE51]] 1 80 80
1 RECEPTION AREA check in (REGISTRATION_Reception /
RCP02 (SC183) 1 260 260
2 RECEPTION AREA Consult Room_2 per 5 to 6 procedure rooms_REDUCED
OFDC2 (SC271) 2 100 200
3 RECEPTION AREA Kiosk, Patient Check-In RCHK2 (SC165) 1 60 60 CUT BACK TO ONE @ 60 sq.ft.
4 RECEPTION AREA Patient Education / Resource Room_REDUCED
CLSC3 [SC171] 1 100 100
5 RECEPTION AREA Patient Education_workstation
SC172 1 40 40
6 RECEPTION AREA Waiting (SB003, 540 NSF FOR
6 ROOMS)
WTG06 (sb003) 1 260 260
7 RECEPTION AREA TOILET VISITOR SB191 1 60 60
1 procedure_ENDO_PM&Rwith anesthesia boom and carts
PROCEDURE Room-ENDO_
PM&R
TRPE2 1 360 360
2 procedure_ENDOSCOPY ONLY_with anesthesia boom and carts
Procedure Room, G.I.
Endoscopy [[annual Colonoscopy, EGD, Esophageal Manometry, Flexible Sigmoidoscopy procedures projected]]
TREE1 (CGE11) 3 320 960
3 procedure_ENDOSCOPY/BRONCHO _with C-ARM
Procedure Room, G.I.
Endoscopy [[annual ERCP, Endoscopic Ultrasound procedures projected]] NEED
PROCEDURES PER YEAR
TREE1 (CGE14) 1 360 360
5 5 1040 1 prep & recovery-ENDOSCOPY Recovery_PREP HOLDING_
{10 X 10} CUBICLE_
CGE26 9 100 900
2 prep & recovery-ENDOSCOPY Recovery ROOM_PACU_3 WALLS_ {11.5'x10'}_2 spaces per 1 procedure
RROP1 (CGE21) 10 120 1,200 from 115 to 120 to fit grid
3 prep & recovery.y isolation anteroom_pacu RECOVERY, ISOLATION ANTE_ CSS243 1 80 80 ok
4 prep & recovery.y isolation_pacu RECOVERY, ISOLATION??
NUMBER PER PROCEDURE
CS242 1 160 160 ok
5 prep & recovery.y isolation_pacu Restroom, ISOLATION 1 60 60 prep & recovery PATIENT CHANGING ROOM 0 160 0 ADDED, per conversation with Zoltan
5 prep & recovery ed 0 60 0 ADDED, per conversation with Zoltan
7 prep & recovery.x ed NCWD4 [SV381] 1 120 120 from 124 to 120 to fit grid
8 prep & recovery.x Nurse Station 1@ 120 per 5 to 8 P. Rooms
NSTA3 [SC152] 1 120 120
8 prep & recovery.x Nurse Station PACU 1@ 120 per 5 to 8 P. Rooms
NSTA3 [SC152] 1 120 120 added cause of 2 separate holding areas
9 prep & recovery.x Toilet, Prep / 2 per 3 to 6 P.
Rooms
[SB201] 2 60 120
10 prep & recovery.x Storage, Equipment [[120 S.F.
if btween 5 & 8 p.rooms
SRE01 [[CGE31]] 1 120 120
11 prep & recovery.x Alcove, Crash Cart RCA01 [[SC052]] 1 20 20
12 prep & recovery.x Alcove, Equipment [2 between 5 & 8]
RCA02 [SC079] 2 30 60
13 prep & recovery.x Exam / Assessment Room EXRG0 [CGE17] 1 120 120
1 MISC alcove, blanket warmer 1 20 20 2 MISC alcove, portable imaging 1 40 40 3 MISC Control Station 1 120 120 4 MISC medication room 0 80 0 repeated (see #4 under suppor area) 5 MISC Scrub / sink? 1 20 20 ask Zoltan
6 MISC alcove, Stretcher Storage(one per two OR
1 40 40
EXRG0 [CGE17]
ANESTHESIA clean workroom anesthesia 1 120 120 yes, pre-cleaning of instruments ANESTHESIA equipment room anesthesia
{1 PER PROCEDURE=6 + 4
BACK UP= 10]
1 120 120 yes
ANESTHESIA gas cylinder 1 80 80 yes, from 81 to 80 ANESTHESIA team room anesthesiaology6 workstations [7 x7 feet cubicles]
2 49 98 [2 providers to chart, reduced to place 2 cubicles 98 to 100 sq. ft.}
1 ADMIN AREA BREAK ROOM, Staff_1@ 140 per 6 to 10 procedure
SL001 [SS262 ] 1 140 140
2 ADMIN AREA Copier / OFFICE SUPPLY Room RPR01 [SS272] 1 80 80
3 ADMIN AREA Office, Digestive Diseases - Endoscopy Service Chief
OFA09 [SS204] 1 100 Shared by Clinicians
4 ADMIN AREA visitor waiting WTG03[[SB0003]] 1 80 80
5 ADMIN AREA Workstation, Admin.
SUPPORT [[1 between 1&10 P. Rooms}}[7 x7 feet cubicles]
OFA07 [SS218] 1 49 49
6 ADMIN AREA Office, Nurse Manager OFA09 [SS204] 1 90 90
7 ADMIN AREA Toilet w/shower, Staff_FEMALE ((LEFT AT A.S.C. standards other wise 60 s.f.))
TNPG1 [SB174] 1 60 60
8 ADMIN AREA Toilet w/shower, Staff_MALE TNPG1 [SB174] 1 60 60
9 ADMIN AREA locker changing room female_1 @ 200 per 6 p.
rooms ((LEFT AT A.S.C.
standards other wise 100 s.f.))
SS232 1 100 100
10 ADMIN AREA locker changing room male_1 @ 200 per 6 p. rooms ((LEFT AT A.S.C. standards other wise 100 s.f.))
SS241 1 100 100
11 ADMIN AREA Workstation, resident[fellows] and nurses [7 x7 feet cubicles]
OFA07 [SS218] 14 49 686 number 14 per service?
GROSS SQ. FT. 9,343
N.T.G. FACTOR X 1.65
NET SQ.F.T. = 15,416
Program for Design (6 procedures)
1 SUPPORT AREA Alcove, Clean Linen LCCL1 [[SC467]] 1 40 40 ok
2 SUPPORT AREA Alcove, Wheelchair SRLW1 [[SB252]] 1 40 40
3 SUPPORT AREA Housekeeping Aides Closet (HAC)
JANC1 1 60 60
4 SUPPORT AREA medication room MEDP1 [[SV583]] 1 80 80
5 SUPPORT AREA Storage, Equipment [[240 S.F. Between 6 &
[[CGE61]] 1 240 240 c-arms, fluroscopies stored after use
6 SUPPORT AREA Storage_instruments, Sterile [[2 X 80 for 6 to 10 rooms}}
SRS04 [[CGE56]] 2 80 160 updated to ONE as for FIVE procedure rooms. Update to TWO if SIX P. Rooms.
SUPPORT AREA EHRM/OIT ROOM ?? 1 100 100 ADDED, per conversation with Zoltan, was not on
SEPS
7 SUPPORT AREA Utility Room, Clean [120 S.F. between 6 & 10 P.
Rooms]
UCCL1 [[SB737]] 1 120 120
8 SUPPORT AREA Utility Room, Soiled [100 S.F. between 6 & 10 P. Rooms]
USCL1 [[SB743]] 1 100 100
1 SPS SPS_Decontamination Room, Scope
USCL2 [[CGE41]] 1 120 120
2 SPS SPS_Reprocessing Room, Scope
USCL3 [[CGE46]] 1 120 120
3 SPS SPS_Anteroom disinfection
1 100 100 Ver SPS guides 60 +60 ppe
4 SPS SPS_Anteroom sterilization
Zoltan 1 100 100 Ver soil room
5 SPS SPS_Storage, Clean Scope [[80 S.F. for 6 to 10 rooms]]
USCL4 [[CGE51]] 1 80 80
1 RECEPTION AREA check in (REGISTRATION_Recept ion /
RCP02 (SC183) 1 260 260
2 RECEPTION AREA Consult Room_2 per 5 to 6 procedure rooms_REDUCED
OFDC2 (SC271) 2 100 200
3 RECEPTION AREA Kiosk, Patient Check-In RCHK2 (SC165) 1 60 60 CUT BACK TO ONE @ 60 sq.ft.
4 RECEPTION AREA Patient Education / Resource Room_REDUCED
CLSC3 [SC171] 1 100 100
5 RECEPTION AREA Patient Education_workstation
SC172 1 40 40
6 RECEPTION AREA Waiting (SB003, 540
NSF FOR 6 ROOMS)
WTG06 (sb003) 1 260 260
7 RECEPTION AREA TOILET VISITOR SB191 1 60 60
0 procedure_Ophtalmology_with anesthesia boom and carts
Procedure Room Ophta TREE1 1 320 320
1 procedure_ENDO_PM&Rwith anesthesia boom and carts
PROCEDURE Room-
ENDO_ PM&R
TRPE2 1 360 360
2 procedure_ENDOSCOPY ONLY_with anesthesia boom and carts
Procedure Room, G.I.
Endoscopy [[annual Colonoscopy, EGD, Esophageal Manometry, Flexible Sigmoidoscopy procedures projected]]
TREE1 (CGE11) 3 320 960
3 procedure_ENDOSCOPY/BRONCHO _with C-ARM
Procedure Room, G.I.
Endoscopy [[annual ERCP, Endoscopic Ultrasound procedures projected]] NEED
PROCEDURES PER YEAR
TREE1 (CGE14) 1 360 360
5 6 1040 1 prep & recovery-ENDOSCOPY Recovery_PREP
HOLDING_ {10 X 10}
CUBICLE_
CGE26 10 100 1,000
2 prep & recovery-ENDOSCOPY Recovery
ROOM_PACU_3
WALLS_ {11.5'x10'}_2 spaces per 1 procedure
RROP1 (CGE21) 10 120 1,200 from 115 to 120 to fit grid
3 prep & recovery.y isolation anteroom_pacu
RECOVERY, ISOLATION
ANTE_
CSS243 1 80 80 ok
4 prep & recovery.y isolation_pacu RECOVERY, ISOLATION?? NUMBER
PER PROCEDURE
CS242 1 160 160 ok
5 prep & recovery.y isolation_pacu Restroom, ISOLATION 1 60 60 prep & recovery PATIENT dressing
ROOM
1 160 160 ADDED, per conversation with Zoltan
5 prep & recovery PATIENT dressing restrm
1 60 60 ADDED, per conversation with Zoltan
7 prep & recovery.x Alcove, Refreshment Center (nourishment station and seating area)
NCWD4 [SV381] 1 120 120 from 124 to 120 to fit grid
8 prep & recovery.x Nurse Station HOLDING 1@ 120 per 5 to 8 P.
Rooms
NSTA3 [SC152] 1 120 120
8 prep & recovery.x Nurse Station PACU 1@ 120 per 5 to 8 P. Rooms
NSTA3 [SC152] 1 120 120 added cause of 2 separate holding areas
9 prep & recovery.x Toilet, Prep / 2 per 3 to 6 P. Rooms
[SB201] 2 60 120
10 prep & recovery.x Storage, Equipment [[120 S.F. if btween 5 & 8 p.rooms
SRE01 [[CGE31]] 1 120 120
11 prep & recovery.x Alcove, Crash Cart RCA01 [[SC052]] 1 20 20
12 prep & recovery.x Alcove, Equipment [2 between 5 & 8]
RCA02 [SC079] 2 30 60
13 prep & recovery.x Exam / Assessment Room
EXRG0 [CGE17] 1 120 120
1 MISC alcove, blanket warmer 1 20 20
2 MISC alcove, portable imaging
1 40 40
3 MISC Control Station 1 120 120 4 MISC medication room 0 80 0 repeated (see #4 under suppor area) 5 MISC Scrub / sink? 1 20 20 ask Zoltan 6 MISC alcove, Stretcher
Storage(one per two
OR
1 40 40
EXRG0 [CGE17]
ANESTHESIA clean workroom anesthesia 1 120 120 yes, pre-cleaning of instruments ANESTHESIA equipment room anesthesia {1 PER
PROCEDURE=6 + 4
BACK UP= 10]
1 120 120 yes
ANESTHESIA gas cylinder 1 80 80 yes, from 81 to 80 ANESTHESIA team room anesthesiaology6 workstations [7 x7 feet cubicles]
180 2 49 98 [2 providers to chart, reduced to place 2 cubicles 98 to 100 sq. ft.}
1 ADMIN AREA BREAK ROOM,
Staff_1@ 140 per 6 to 10 procedure
SL001 [SS262 ] 1 140 140
2 ADMIN AREA Copier / OFFICE SUPPLY Room
RPR01 [SS272] 1 80 80
3 ADMIN AREA Office, Digestive Diseases - Endoscopy Service Chief
OFA09 [SS204] 1 100 Shared by Clinicians
4 ADMIN AREA visitor waiting WTG03[[SB0003]] 1 80 80
5 ADMIN AREA Workstation, Admin.
SUPPORT [[1 between 1&10 P. Rooms}}[7 x7 feet cubicles]
OFA07 [SS218] 1 49 49
6 ADMIN AREA Office, Nurse Manager OFA09 [SS204] 1 90 90
7 ADMIN AREA Toilet w/shower, Staff_FEMALE ((LEFT AT A.S.C. standards other wise 60 s.f.))
TNPG1 [SB174] 1 60 60
8 ADMIN AREA Toilet w/shower, Staff_MALE
TNPG1 [SB174] 1 60 60
9 ADMIN AREA locker changing room female_1 @ 200 per 6
p. rooms ((LEFT AT A.S.C. standards other wise 100 s.f.))
SS232 1 100 100
10 ADMIN AREA locker changing room male_1 @ 200 per 6 p.
rooms ((LEFT AT A.S.C.
standards other wise 100 s.f.))
SS241 1 100 100
11 ADMIN AREA Workstation, resident[fellows] and nurses [7 x7 feet cubicles]
OFA07 [SS218] 14 49 686 number 14 per service?
GROSS SQ. FT. 10,063
N.T.G. FACTOR x 1.65
NET SQ.F.T. = 16,604
| 4. SOW_Expand Ambulatory Services at Building 19 20 |
| 4. SOW_Expand Ambulatory Services at Building 19 21 |
| 4. SOW_Expand Ambulatory Services at Building 19 22 |
| 4. SOW_Expand Ambulatory Services at Building 19 23 |
| 4. SOW_Expand Ambulatory Services at Building 19 24 |
| 4. SOW_Expand Ambulatory Services at Building 19 25 |
| 4. SOW_Expand Ambulatory Services at Building 19 26 |
| 4. SOW_Expand Ambulatory Services at Building 19 27 |
| 4. SOW_Expand Ambulatory Services at Building 19 28 |
| SOW Attachments_Expand Ambulatory Services at Building 19 |
File details come from the government source that posted it. Updated .