SOW Attachment 10 - XMatrix Providence RI.xlsx

XLSX spreadsheet 28 KB Posted

Attached to
C1BG--650-22-700 EHRM Infrastructure Upgrades Providence RI (VA-22-00022183)
Solicitation number
36C77622R0136
Issued by

About this file

This pre-solicitation notice seeks Statements of Qualifications from architecture and engineering firms for design services related to infrastructure upgrades at the VA Providence Healthcare System in Providence, Rhode Island. The project includes upgrades to network infrastructure, structured cabling, electrical distribution, UPS systems, building management systems, HVAC, telecommunications rooms, the data center, and security systems across multiple buildings. The estimated value of construction is between $20-50 million.

Firms must submit an SF330 by July 29, 2022. The selection will be based on specialized experience with similar IT and network infrastructure projects, professional qualifications of staff, capacity to complete the design by the 290-day deadline, past performance, and knowledge of local conditions. Past performance references and CPARS data must be included for any projects listed in the SF330. This is a 100% SDVOSB set-aside administered by the VA's Technology Acquisition Center, with the design contract to be awarded by November 2022.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

XMATRIX Summary

StationLocationNameBuildingRoomCablingPatch PanelsFiberPowerBondingUPSDedicated CoolingTempHumidityRacks SensorsSpaceNotes
650VA ProvidenceProvidence medical center1100AXXXXXXXXXXX6 racks; 2 racks to move to basement; TR Tower
650VA ProvidenceProvidence medical center1Basement TR1XXXXXXXXXXXNo TR currently in basement
650VA ProvidenceProvidence medical center1200AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1300AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1400AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1500AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1600AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1700AXXXXXXXXXXX3 racks minimum; TR Tower Stack
650VA ProvidenceProvidence medical center1D1058XXXXXXXXXXXrack for basement and rack for 2nd Fl
650VA ProvidenceProvidence medical center1Basement TR2XXXXXXXXXXXreplace D1058
650VA ProvidenceProvidence medical center12nd Floor TRXXXXXXXXXXXreplace D1058
650VA ProvidenceProvidence medical center1E001NONONONONONONONONONONOno port count, verify; mechanical space; out of scope
650VA ProvidenceProvidence medical center1E116XXXXXXXXXXNO
650VA ProvidenceProvidence medical center1E222XXXXXXXXXXNO
650VA ProvidenceProvidence medical center1E322XXXXXXXXXXNO
650VA ProvidenceProvidence medical center1E423XXXXXXXXXXNO
650VA ProvidenceProvidence medical center1012IXXXXXXXXXXNOOR TR
650VA ProvidenceProvidence medical center11st Fl TRXXXXXXXXXXXOR TR
650VA ProvidenceProvidence medical center12nd Floor TR2XXXXXXXXXXXOR TR
650VA ProvidenceProvidence medical center1S222XXXXXXXXXXX
650VA ProvidenceProvidence medical center2B1AXXXXXXXXXXNO
650VA ProvidenceProvidence medical center3B1XXXXXXXXXXNO
650VA ProvidenceProvidence medical center5B2XXXXXXXXXXX
650VA ProvidenceProvidence medical center7110XXXXXXXXXXX
650VA ProvidenceProvidence medical center8106XXXXXXXXXXNOwarehouse; remodel 2-3 years ago
650VA ProvidenceProvidence medical center9123XXXXXXXXXXX
650VA ProvidenceProvidence medical center10201NONONONONONONONONONONOBoiler Plant under design; Project #650-19-100; out of scope
650VA ProvidenceProvidence medical center14B1XXXXXXXXXXNOB14 also supports B6 connected; underground conduit
650VA ProvidenceProvidence medical center32B2XXXXXXXXXXNOResearch basement; will request exemption for 1st fl TR
650VA ProvidenceProvidence medical center321st Fl TRXXXXXXXXXXXResearch 1st floor
650VA ProvidenceProvidence medical center35008XXXXXXXXXXNO
650VA ProvidenceProvidence medical center35132XXXXXXXXXXX
650VA ProvidenceProvidence medical centerTR7/8101XXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR18107AXXXXXXXXXXNOLeased trailer; no space due to limitations of trailer (police service)
650VA ProvidenceProvidence medical centerTR32RM15XXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR33108XXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR34no room numberXXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR35109XXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR36108XXXXXXXXXXNOLeased trailer
650VA ProvidenceProvidence medical centerTR37no room numberXXXXXXXXXXNOLeased trailer
650VA ProvidenceNew Bedford CBOC (650GA)650GA123XXNOXXXXXXXXNew Bedford VA Clinic (VA Owned); including with 700 project
650VA ProvidenceHarwood Research Center650TRXXNOXXXXXXXXHarwood Research Center (VA Owned); including with 700 project

VAMC TOTALS 40 40 40 38 40 40 40 40 40 40 40 21 2

StationLocationNameBuildingRoomCablingPatch PanelsFiberPowerBondingUPSDedicated CoolingTempHumidityRacks SensorsSpaceNotes
650VA ProvidenceNew Bedford CBOCNB123NONONONONONONONONONONOVA owned; Moved above to the 700 project
650VA ProvidenceMiddletown CBOCMT101ANONONONOXXXXXXXLease term 9/10/2021
650VA ProvidenceHyannis CBOCHY122CNONONONOXXXXXXXLease term 7/7/2017;
650VA ProvidenceCape Cod Vet Center/Hyannis Vet CenterHYVno room numberNONONONONONONONONONONOVet Center;Out of scope
650VA ProvidenceNew Bedford Vet Center/Fairhaven Vet CenterFHVno room numberNONONONONONONONONONONOVet Center;Out of scope
650VA ProvidenceProvidence Vet Center/Warwick Vet CenterWRVno room numberNONONONONONONONONONONOVet Center;Out of scope
650VA ProvidenceProvidence medical centerEagle 1109NONOXNOXXXXXXXWAN and primary demark
650VA ProvidenceProvidence medical centerEagle 2106NONOXNOXXXXXXNO
650VA ProvidenceProvidence medical centerEagle 3near 344NONOXNOXXXXXXX
650VA ProvidenceProvidence medical centerEagle 4225NONONONONONONONONONONORemoved
650VA ProvidenceProvidence medical centerEagle 5111NONOXNOXXXXXXNO
650VA ProvidenceProvidence medical centerEagle 6145NONOXNOXXXXXXX
StationData CenterBuildingBuildingRoomSpaceHVACCable DistroWANUPSNOTES
650VA ProvidenceProvidence medical center4201XXXXXNo HVAC info provided
General Notes
X~included in scope of NRM project
NO~not included in scope
TR Notes
Cabling:
Fiber:
Power:
Data Center Notes
Rectangular; 900 sq. ft.; Core switches located in the DC (mix of OIT, FMS and BioMed), core routers also in DC
Demarc is in PBX downstairs, 100% VOIP, analog lines are decommissioned and removed, only copper lines to out-buildings (50 or 100 pr cables)
Raised floor; cable/power distribution 20% occupied; Hot and Cold aisle arrangement; 2 rows IT; 1 row core switches/routers; CRACs ends of rows
No diverse WAN circuits same LEC provider
Floor space constraints: 75% of space needed for hot and cold aisle arrangement
3ft space above cabinets to dropped ceiling, possible additional space above dropped ceiling of about 4 ft
Dedicated Generator for Building 4; Fire suppression only sprinkler
*CRACs:2 Liebert up flow CRACs replaced in 2020 (105 kW/30 ton), located at end of rows, ducted overhead, diffusers not placed on cold isle (random)
hot/cold isle configuration, 2 row of IT, 1 row of core equip
cold air blowing down from random diffusers in room, back of cabinets face each other

*Power: 2 UPSs (Eaton Powerware 9390) - 90 kW rated (incl 0.9 power factor), 20-30% load (avg)

Is the Data Center able to accept the JSA and FDSS at the time of scoping?
JSA - ReadinessAble to accept. UPS and cooling are sufficient and redundant; floor space constraints
FDS -ReadinessAble to accept. UPS and cooling are sufficient and redundant; floor space constraints

DropDown Values

Space UseUPSHVACSPACEDISTRICTTERRITORY
ADMINInstalled - AdequateInstalled - AdequateYESAdequate - Room for expansion1T1
CLINICALInstalled - InadequateInstalled - IndequateNOAdequate - No room for expansion2T2
OtherNot InstalledNot InstalledInadequate - makeshift installations3T3
ExcludeMissing dataMissing data4T4
5T5

File details come from the government source that posted it. Updated .