SOW Attachment 1 Inspection Criteria.pdf
PDF 2 MB Posted
- Attached to
- Fall Arrest Inspection Services Federal contract opportunity
- Solicitation number
- FA462020QA342
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 2 OPSEC Measures.pdf | ||
| Attachment 1 SOW.pdf | ||
| FA462020QA342 Combo.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA462020QA342
SOW Attachment 1
Inspection, Care & Maintenance
Horizontal Lifelines
Frequency:
Visually inspect anchors and connectors before each use in accordance with manufacturer's instructions.
Damaged systems and components must be removed from service immediately.
In the event of a fall, the system must be removed from service, inspected, repaired and recertified for use by Evan Corporation.
Inspect system components for:
• Excessive corrosion, dents, cracks, fraying and deformities.
• Check end anchor fasteners and intermediate brackets (end anchors must be torqued at 75 ft.lbs. and intermediate brackets at 18 ft.lbs.).
• Check site label(s) making sure they are present, legible, and secured near an access location.
• Inspect User Equipment per associated manufacturer's instructions. Check connecting means for wear or deformities.
FA462020QA342
Inspection, Care & Maintenance
Rigid Rail - Enclosed Track and Wide Flange Beams
• Check site label(s) making sure they are present, legible, and secured near an access location.
• Inspect system prior to each use as per ANSI.
• Inspect User Equipment per associated manufacturer's instructions.
• Refer to the instructions supplied with the harness, lanyard and self-retracting lifeline for cleaning and servicing procedures. Store the harness, lanyard or self-retracting lifeline in a cool, dry clean environment and out of direct sunlight.
• In the event of a fall, the system must be removed from service until it is inspected and approved for us.e.
FA462020QA342
| Fall Arrest Inspection Critera FY20 SOW Attachment 1 |
| Fall Arrest Inspection Criteria SOW Attachment 1 AFI OUTDATED |
File details come from the government source that posted it. Updated .