SOW Antenna LMR. 17-Jan-2024.pdf

PDF 80 KB Posted

Attached to
LMR Antenna PMI Federal contract opportunity
Solicitation number
FA301024Q0007
Issued by
Department of the Air Force Air Education and Training Command

About this file

This document contains a statement of work and federal contract opportunity solicitation for an annual LMR antenna preventative maintenance inspection at Keesler Air Force Base. The statement of work requires the contractor to inspect coaxial cables, grounding points, surge protection systems, antenna cabling, and cable support systems at three antenna locations. The contractor must prepare a discrepancy report with repair and replacement pricing. The solicitation provides details for an organized site visit on February 20, 2024 and requires interested parties to register attendees by February 14. Offerors are expected to inspect the work sites. The solicitation is issued by the Department of the Air Force Air Education and Training Command to complete the preventative maintenance inspection in accordance with the January 17, 2024 statement of work.

View the file

Other files for this federal contract opportunity

Other files attached to LMR Antenna PMI, newest first.
File Type Posted
Solicitation - FA301024Q0007.pdf PDF
Wage Determination.pdf PDF
Position Description Wage Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

17 January 2024

STATEMENT OF WORK

Annual Keesler LMR Antenna Preventative Maintenance Inspection (PMI) Requirement

The contractor shall inspect all items listed below and prepare a discrepancy report with repair/replacement pricing for each antenna. Locations are Bldg 4241/4225 (35 ft tower), Bldg 4330 (rooftop), and Bldg 4609/4605 (150 ft tower):

• Inspect all coaxial cables.

• Inspect all grounding points. The report must provide repair and reapplication of antioxidant information if necessary (ANSI/TIA 607-D).

• Inspect RF coaxial surge protection grounding PFAS system.

• Inspect all antenna cabling duct seals.

• Verify brass tags and/or vinyl labels on both ends of all cables.

• Inspect ground bus bar connections. The report must provide repair and reapplication of antioxidant information if necessary.

• Inspect polyphasers for coaxial cables.

• Inspect all coaxial cables to towers/buildings/mounts (T.O. 31-10-14).

• Inspect cable support system to transition cables from towers to building cable port (BICSI OSP Design Reference Manual 6th edition).

• Verify surge arrestors inside facility (NFPA-780, ANSI/TIA-607-D).