SOW 17 Diasorin Liaison MDX VISN 1 Dmc 10 27 20.docx

DOCX document 23 KB Posted

Attached to
6640--Diasorin equipment VISN 1 Labs (VA-21-00007926) NOI to Sole Source-Response due 11/23/20-3:00 P. M.
Solicitation number
36C24121P0151
Issued by

About this file

This statement of work outlines technical specifications and services requested by Veterans Integrated Service Network 1 laboratories for the purchase of 17 Diasorin Liaison MDX 3m integrated cyclers from Diasorin. The equipment will expand high-volume COVID-19 testing capacity at various VA medical centers in VISN 1 by 3,264 additional tests per week. The standardization of the Diasorin platform across Network labs will help resume pre-surgical testing and clinic operations. The notice of intent to sole source indicates the Department of Veterans Affairs intends to acquire the 17 Diasorin systems from the sole manufacturer, Diasorin, with responses to the notice due by November 23, 2020. The vendor will deliver, install, and train staff on the equipment per the statement of work specifications.

View the file

Other files

File Type Posted
36C24121P0151.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VISN 1 Diasorin equipment DIASORIN LIAISON MDX 3M INTEGRATED CYCLER for Pathology & Laboratory Medicine Statement of Work

Objective This document highlights the technical specifications and services being requested by the VISN 1 labs for consideration towards the purchase of 17 Diasorin 3m Cyclers. Vendor under this proposal shall provide all equipment, accessories, installation, applicable training, and manuals for 17 Diasorin Liaison MDX 3m Cyclers. This request is for 4 units at VA Togus, 2 at VA White River Junction, 1 at VA Jamaica Plain, 4 at VA West Haven, 3 at VA West Roxbury, 1 at VA Bedford, 1 at VA Manchester and 1 at VA Brockton. This is to expand high volume COVID19 testing in VISN1 NCL, to standardize testing cartridges, calibrators, and controls to our current Diasorin testing VISN 1 platforms. Note the current Diasorin. This will increase COVID testing capabilities by 3264 tests per week. There will be an additional request for COVID-19 testing reagents. The use of standardized testing platforms enables sites to enhance testing and share resources and remain standardized at the same time.

Project Management / Equipment Implementation Product delivery will be the responsibility of the Vendor working with the VISN 1 sites. VAMC clinical engineering POC. The Vendor will be responsible for coordinating and performing the delivery, implementation, and training for installation Background/Justification d/Justification/ Diasorin is the only vendor which sells the liaison MDX 3m cycler Instrument The LIAISON® MDX is unique thermocycler allowing us to run real-time PCR for qualitative, quantitative and multi-analyte detection, and more specifically COVID19 nucleic acid detection. The standardization of the Diasorin liaison MDX 3m cyclers will Help with testing pre surgical patients and get the VA clinics active again. Demand for Covid-19 testing far exceeds our current capacity and at the same time we can standardize testing platforms in the VISN1 Network Labs. There is currently a national pandemic and COVID19 testing ability and capacity is an urgent need.

Equipment Specifications System Equipment

MOL1001-P DIASORIN LIAISON MDX 3M INTEGRATED CYCLER, 110V

MOL1100 IC ACCESSORY KIT

MOL1200-L LAPTOP COMPUTER

MOL1300 PRINTER, INTEG CYCLER SYST

MOL1301 USB Printer Cable

Training Provided / Training Materials

1. Vendor will be required to provide user manuals for the Diasorin Liaison MDX

2. Vendor will be required to provide an on-station in-service on the proper use and setup of the Diasorin Liaison MDX.

3. Vendor to provide full 1 -year warranty on cycler and peripherals.

4. All VISN1 sites are eligible to participate in this contract at a later date as needed. These sites are VA Central Western MA, VA Worcester OPC, VA Newington and VA Providence.

5. The emergent needs of this instrumentation throughout VISN 1 precludes these systems from attaching to the VA network.