This is a Request for Information (RFI) and Sources Sought notice issued by the Department of Veterans Affairs Veterans Health Administration for the VA San Diego Healthcare System seeking information on qualified sources capable of providing oxygen units. The RFI is for planning and market research purposes only and does not constitute a solicitation or binding contract. The government is specifically interested in the Fisher & Paykel Airvo 3 Respiratory Support Device system, including five units of the base device (PT301US), manifolds, pole stands, oxygen bottle holders, clamps, and DISS connectors in specified quantities.
The required equipment must deliver high-flow warmed and humidified oxygen to spontaneously breathing patients with an integrated 40-minute battery, integrated oxygen blender with FiO2 range of 21-100%, screen lock capability, visual and auditory alarms grouped by priority level with corrective action suggestions, and air filter change indicators. Responses must address 17 specific requirements including capabilities statements, business size classification under NAICS 339112 (1,000 employee threshold), manufacturer or distributor status, compliance with limitations on subcontracting, COTS certification, Buy American Act conformance, FDA clearance status, lead times, existing federal contracts, and general pricing for market research purposes only. All responses must be submitted via email to Carlo.manuel@VA.gov by Wednesday, May 20, 2026, at 9:00 a.m. PST. Responses are not offers and will be used solely for acquisition planning; interested parties must separately respond to any future solicitation announcements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26226Q0816.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.
SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).
DISCLAIMER
This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
RFI/SOURCES SOUGHT DESCRIPTION
This is NOT a solicitation announcement. This is an RFI Notice only. The purpose of this RFI Notice is to gain information about potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI Notice, further RFIs and/or solicitation or other announcements may be published.
The Department of Veterans Affairs (VA) is seeking information on and sources capable of providing Oxygen Units for the VA San Diego Healthcare System.
Brand-Name Product Information:
Manufacturer Fisher & Paykel
| Item # |
| Description/Part Number* |
| Qty |
| Unit |
| 1 |
| Airvo 3 Base Respiratory Support Device (PT301US) |
| 5 |
| EA |
| 2 |
| Airvo 3 HPO Dual-Input Manifold (900PT460D) |
| 5 |
| EA |
| 3 |
| Pole Stand, Hospital Pole for my Airvo 2 and Airvo 2 on wheels |
| 5 |
| EA |
| 4 |
| Oxygen Bottle Holder (900PT427) |
| 5 |
| EA |
| 5 |
| C-Clamp 25 mm |
| 5 |
| EA |
| 6 |
| 10' DISS female hex by female hand tight (HA-U1C4-02414 |
| 5 |
| EA |
| 7 |
| 2' DISS female hex by female hand tight (HA-U1C4-00894) |
| 10 |
| EA |
Salient Characteristics:
· Must deliver high flow warmed and humidified oxygen to spontaneously breathing patients through a variety of interfaces.
· The device has integrated battery lasting up to 40 minutes with status indicators displaying the % battery charge.
· It has an integrated blender with high-pressure oxygen input to enable precise FiO2 and automatically adjusting O2 input to meet target FiO2.
· FiO2 range must be 21% to 100%.
· Must be able to lock screen to prevent accidental changes to therapy.
· Must have visual and auditory alarms to notify users about interruptions to a patient’s treatment.
· The alarms must be grouped by urgency and severity into low, medium, and high priority.
· Alarms should display with suggested actions for correction.
· Must provide visual display when the air filter requires changing to remind users.
If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.
(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.
(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.
(4) Is your company considered small under the NAICS code identified in this RFI?
(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?
(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).
(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.
(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?
(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?
(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?
(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.
(12) What is your lead time to deliver all items?
(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.
(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).
(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.
(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.
(17) Please provide your SAM.gov Unique Entity ID number.
Responses to this notice shall be submitted via email to Carlo.manuel@VA.gov. Telephone responses will not be accepted. Responses must be received no later than Wednesday, May 20, 2026, at 9:00 am PST.
All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.
File details come from the government source that posted it. Updated .