The solicitation number is W50S8R24R5029 and the NAICS code is 335999. The government is conducting market research to identify potential sources capable of providing UPS equipment meeting specific technical requirements, including input/output voltages, power ratings, battery runtime, and network connectivity. Interested vendors are invited to submit responses of no more than 3 pages by 10:00 AM EST on August 6, 2024, providing capability statements and contact information. This is for market research purposes only and will not determine vendor qualifications or impact future solicitations. The government will not pay for any costs associated with responding to this notice. All future solicitations will be evaluated independently of the information provided here.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTICE: Sources Sought

SOLICITATION NUMBER: W50S8R24R5029

RESPONSE DATE: 6 August 2024 10:00 AM EST NAICS Code: 335999 This announcement constitutes a Sources Sought Synopsis (market survey). This is not a request for quote (RFQ) or a request for proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The Government will not pay for any cost incurred in responding to this announcement. Any information submitted by respondents to this Sources Sought synopsis shall be voluntary.

This Sources Sought Notice is for Market Research purposes only. The information submitted in response to the Sources Sought Notice will not be utilized to determine vendor standing in any future/potential Request for Quote/Request for Proposal, nor will it be utilized to determine if a vendor is qualified to submit a Request for Quote/Request for Proposal for any future/potential requirement. The notice and the information received shall not be used to determine how well respondents can perform a requirement, which can only be evaluated in response to a solicitation. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought request. All future/proposed submissions/solicitations requirements solicited on a Government Point of Entry will be evaluated independent of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought request.

This Sources Sought Notice is relative to the NAICS code 335999. Large and Small Businesses are invited to answer this market survey to determine market capabilities.

The 179th CW/MSC, Mansfield, OH, is conducting market research to determine the existence of potential sources to provide uninterrupted power supply meeting the following salient characteristics:

CLIN
Salient Characteristics
0001 - UPS
Input voltage: 120V

Output voltage: 120V Kw rating: 1000 Rated power in VA: 1440 VA Input connection type: NEMA 5-15P Output connection type (min qty): NEMA 5-15R (6) Number of rack units: 2U Battery Type: Lead Acid Color: black or grey/silver (no white) Mounting mode: Rack-mounted Battery runtime: minimum of 15 minutes at 50% load capacity (500 W)

Other: ability to connect to and be managed via a network connection.

0002 - UPS
Input voltage: Range of 150-280VAC

Output voltage: 120/208 (configurable) Kw rating: 6000W Rated power in VA: 6000 VA Input connection type: hard wired Output connection type (min qty): hard wired Number of rack units: Double conversion Battery Type: Lead Acid Color: black or grey/silver (no white) Mounting mode: Rack-mounted Battery runtime: minimum 3 minutes backup time on based on 50% load

Other: ability to connect to and be managed via a network connection.

NOTE: Please submit electronic response indicating capability to provide services (no more than 3 pages) as well as POC (name, telephone # and email address) along with contractor’s CAGE, DUNS, and the physical location of your facility to the individuals listed within this notice.

Required Information: Any interested party who can offer all of the above may submit a written reply of not more than 3 pages, addressing each of the above items and defining how their location is capable of ALL of the minimum requirements listed above.

Response Deadline: 10:00 AM EST, 6 August 2024 Where to Send Responses: jeffrey.snyder.20@us.af.mil

File details come from the government source that posted it. Updated .