Sources Sought_CDER-2025-126411_FINAL.pdf
PDF 134 KB Posted
- Attached to
- Milliflex Rapid 2. 0
- Solicitation number
- SSN_CDER-2025-126411
About this file
This is a Sources Sought Notice (SSN) issued by the FDA's Office of Pharmaceutical Quality Research (OPQR) seeking vendors capable of providing the Milliflex Rapid 2.0 Detection System and related equipment for microbial quality control testing. The system must be compatible with OPQR's existing 2nd gen Milliflex Oasis filtration pump and will be used to test microbial quality of purified bulk drug substances and final formulated drug products.
The required equipment includes the Milliflex Rapid 2.0 Detection System kit, power supplies, filtration pump, filtration heads, cleaning kits, reagents, funnels, media plates, and various accessories. Installation, IQ/OQ validation, and on-site training for 3-5 personnel are required within 45 days of award. Delivery and installation will be at the FDA facility in Silver Spring, MD. The period of performance is one year from installation. Responses from both small and large businesses are due by January 30, 2024 at 12:00 PM ET and must include company details, NAICS codes, socioeconomic status, GSA schedule information, domestic manufacturing status, and technical specifications. The notice explicitly states this is for market research only and not a formal solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought_CDER-2025-126411_FINAL.pdf | ||
| Draft_SOW_CDER-2025-126411.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
Milliflex Rapid 2.0
CDER-2025-126411
PURPOSE
This Sources Sought Notice (SSN) is for market research, information, and planning purposes ONLY. This SSN does not in any way constitute a Request for Quotation (RFQ) and as such, shall not be construed as a commitment by the Government (implied or otherwise) to issue a solicitation or ultimately award a contract.
This announcement is specifically targeted to a) identify vendors capable of providing the equipment as detailed in this notice, and b) vendors capable of providing a domestic product offering. Responses from small and other than small businesses are appreciated and accepted.
REQUIREMENT
A. BRIEF DESCRIPTION OF REQUIREMENT/STATEMENT OF NEED:
CDER’s Office of Pharmaceutical Quality Research (OPQR) requires the purchase of rapid microbial limit detection equipment capable of confirming the presence of bioburden contamination for microbial quality control testing using membrane filtration with ATP detection. This system will expand our current capabilities to test the microbial quality of purified bulk drug substance and final formulated drug product as well as support research into the robustness of rapid/alternative microbial detection methods used by industry. OPQR currently owns and operates a 2nd gen Milliflex Oasis filtration pump (MMSYSTMM2) which uses specific filter funnels and microbial culture accessories to fit the pump head. The reqired membrane filtration + ATP detection system - Milliflex Rapid System 2.0 (Millipore Sigma)-must have an autospray station and detection tower compatible with this existing pump and filter membranes.
B. SYSTEM DESCRIPTION:
System shall have standard 110V/60Hz U.S. plugs.
Item Part # Quantity
HARDWARE & ACCESORIES
Milliflex Rapid 2.0 Detection System kit (inl.
1x MXRP2SPRKT and 1x MXRDP2DT00) without power supply
MXRDP2KT01 1.00
MFR 2.0 & sprayer power supply - US MXRPWRSPUS 1.00
Milliflex Oasis® filtration pump without filtration head WITH power supply (US)
MMSYSTMM2 1.00
Milliflex Oasis filtration head, 2nd generation
MHEADMM2 2.00
Item Part # Quantity
HARDWARE & ACCESORIES
Stainless steel tool used to perform control test of Milliflex Rapid hardware system
P0SIC0NT1 1.00
Milliflex Rapid Cleaning/Decontamination Kit. Includes: Rinsing agent (4 bottles/pk), Cleaning agent (4 bottles/pk), Decontamination agent (1 bottle/pk), Luer-Lock caps (10/pk), Vial adapters (9/pk). For 20 cleanings and 2 decontaminations.
MXRPCLKT1 1.00
Milliflex Rapid Reagent Kit (100 tests) MXRPBLRST 1.00
Milliflex Oasis® rapid - 100 mL funnel, 0.45 μm white plain, PVDF Durapore® membrane (24)
MMHVMFX24 4.00
Milliflex Oasis® media plate prefilled with TSA Agar (48)
MMSMCTS48 2.00
Milliflex Oasis membrane support removal tool
MMSUPREMV 1.00
Milliflex Oasis internal flow sanitization kit MMSANKIT1 1.00
Installation IQ/OQ, training
Milliflex Rapid V2.0 with Milliflex Oasis e- Protocol Service for IQ & OQ
MXRPIQOQEP 1.00
On-site Milliflex Rapid System IQ/OQ and PQ consulting+ training (up to 3 days) on equipment use and maintenance
RSVALID11 1.00
On-site Milliflex Oasis pump IQ/OQ + training on equipment use and maintenance.
BSVALID11 1.00
Delivery & Installation 1.00
C. PERFORMANCE PERIOD:
Period of performance will be one year from the delivery and installation of the instrument.
D. PERFORMANCE REQUIREMENTS:
To meet the purpose and objective of this requirement, the Contractor shall provide the following:
General Service Requirements:
• Only certified field technicians must be used for installation and training
• Scheduling must be Monday-Friday between the hours of 9 am-4 pm EST.
• Scheduling to be coordinated through the TPOC on the contract
• All technicians must have a valid U.S. Driver’s license for entry through security
E. DELIVERY REQUIREMENTS
Receipt of all equipment, accessories, installation, and training must be guaranteed <45 days after award date unless otherwise postponed by the FDA.
a. Accessories and warranty
i. Quote shall include all necessary starter kits, pumps, tubing, and consumables required for initial use.
b. Delivery, Installation, and Training:
i. On-site training and installation shall be included in the price.
1. Installation shall include setting up machine and performing installation and operational qualification (IQ/OQ).
2. Training shall include on-site application training or no more than 3 days for up to 3-5 personnel.
3. Period of Performance shall cover all parts and installation for at least 1 year after completion of all IQ/OQ.
ii. The vendor shall provide shipping, handling and inside delivery to the individual(s) and delivery location outlined below in Section 5 Shipping/Destination.
iii. End user applications training should be delivered at the time of installation by a qualified individual. Training should not be unnecessarily delayed or postponed by the Contractor.
iv. At least 2 weeks prior to anticipated delivery date, a pre-installation planning meeting between FDA laboratory staff receiving the equipment and person(s) responsible for delivery, installation, IQ/OQ, and equipment training should take place to confirm tasks, deliverables, and schedules of both parties.
F. SHIPMENT/DESTINATION:
10903 New Hampshire Ave
Building 72, Second floor labs
Silver Spring, MD 20993
The FDA’s Technical Point of Contact (TPOC) will approve all tasks and deliverables.
For all on-site maintenance, the Contractor’s personnel are required to report to the security guards at the White Oak Building 75, 10903 New Hampshire Ave, Silver Spring, MD 20993, who will contact the TPOC or his or her designated FDA employee. The Contractor’s personnel shall be escorted by the TPOC or his or her designated FDA employee at all times while working on-site under this order. The Contractor shall perform all on-site maintenance service during the hours of 9:00 am to 5:00 pm ET, Monday through Friday, unless otherwise indicated by the TPOC.
The TPOC will be responsible for determining the acceptance of the work that is completed.
Capable firms must submit their responses to the below questions.
REQUESTED INFORMATION
Please provide the following information:
▪ Company's name, mailing address, Cage Code, and Unique Entity Identifier (UEI)
▪ Recommended North American Industry Classification System (NAICS) code that your company utilizes for in support of the following equipment: Motion Capture System
▪ What is your company size? If small, what is your socio-economic status?
▪ Identify any GSA Schedule contract or other current government-wide contract (e.g., GWAC or BPA) that your company currently holds and offers these products/services under.
▪ Domestic manufacturing status.
▪ Technical specifications for the proposed solution.
DISCLAIMER
The Government will not reimburse respondents for any costs associated with information submitted in response to the SSN. Responders are solely responsible for all expenses associated with responding to this SSN.
Responses to this SSN are not offers and cannot be accepted by the Government for the basis of forming a binding contract. This SSN is being issued solely for the purpose of gathering information for planning purposes. This SSN does not commit the Government to a contract for any supply or service. Furthermore, the Government is not at this time seeking quotes and will not accept unsolicited quotes.
Respondents to this SSN may be requested to provide additional information/details based on their initial submittals. The Government reserves the right to select, one (1), some, or none of the submissions for further information. Vendors who submit information in response to this
SSN do so with the understanding that U.S. Government personnel may review their materials and or data.
RESPONSE DEADLINE
Responses shall be submitted in writing by e-mail to Contract Specialist, Iris Johnson, at
Iris.Johnson1@fda.hhs.gov, and Contracting Officer, Maria Finan, maria.finan@fda.hhs.gov, no later than January 30, 12:00 pm ET. Questions regarding this SSN must be submitted via email as telephone inquiries will NOT be addressed and shall NOT contain proprietary or classified information.
mailto:Iris.Johnson1@fda.hhs.gov
File details come from the government source that posted it. Updated .