Sources Sought 36C26327Q0044 Details Page.docx
DOCX document 16 KB Posted
- Solicitation number
- 36C26327Q0044
About this file
This is a Sources Sought notice issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 for the Iowa City VA Health Care System Research Department. The notice seeks domestically produced equal versions of an iCare MAIA 3.0 microperimeter, specifically a fundus-based microperimeter device required for the Research Department's operations. This pre-solicitation is designed to identify potential vendors and suppliers capable of providing equivalent equipment before a formal solicitation is issued.
Interested vendors must submit responses no later than 5:00 PM Central Time on Thursday, October 15, 2026, with all submissions to be emailed to Joseph.Bennett@va.gov. The solicitation number 36C26327Q0044 must be included in the subject line of all email submissions. This Sources Sought notice allows the VA to assess market capability and gather information on available domestically produced alternatives to the specified iCare MAIA 3.0 microperimeter prior to proceeding with formal procurement procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26327Q0044.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOURCES SOUGHT 36C26327Q0044 for an iCare MAIA 3.0 microperimeter.
The Iowa City VA Health Care System Research Department requires the purchase of an iCare MAIA 3.0 microperimeter (Fundus-based microperimeter).
This is a SOURCES SOUGHT NOTICE seeking American manufactured equipment only. Respond if your firm can provide a domestically produced equal or comparable model. This Sources Sought is for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as an obligation on the part of the Department of Veterans Affairs.
The Buy American Act, FAR 52.225-1, applies. Interested vendors shall include the place of manufacture in their responses.
No response is required for foreign manufactured products.
Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. This information will assist the Government in understanding the application of Buy American Statute and will be used by the Government in developing its acquisition strategy regarding possible set aside for Veteran Owned and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice.
The North American Industry Classification System (NAICS) code for this requirement is 339112 Surgical and Medical Instrument Manufacturing, with an SBA Small Business Size Standard of 1,000 employees.
To respond:
All responses must be received no later than 05:00 PM CT, Thursday, October 15, 2026.
All responses shall be emailed to Joseph.Bennett@va.gov.
All emails shall have this number in the subject line: 36C26327Q0044
Description:
iCare MAIA 3.0 microperimeter.
Salient Characteristics:
Fundus-based microperimeter MAIA 3.0 with 60° TrueColor confocal fundus image, matching the spatial extent of LSFG blood flow retinal imaging and enabling complete registration of LSFG blood flow maps with sensitivity data across the retina. Scanning laser ophthalmoscope (SLO)-based confocal active retinal tracker operating at 25 Hz, providing real-time, high-fidelity compensation for eye fixation instability. Onboard custom grid editor that allows the operator to import patient-specific stimulus locations derived directly from multimodal imaging, including LSFG blood flow maps. Mesopic background luminance (4 asb) as its standard testing condition.
Line items:
| Qty of 1: | iCare MAIA 3.0 microperimeter. |
| Qty of 1: | Ophthalmic table for the MAIA 3.0 |
| Qty of 4: | Hour of remote or in-person training. |