SOR - Concrete footings.pdf
PDF 85 KB Posted
- Attached to
- RFI - Concrete Footings
- Solicitation number
- FA9302991234
About this file
This document is a Statement of Requirements (SOR) for concrete footings for a large area maintenance shelter, as well as a related Request for Information (RFI) for the same requirement.
The SOR details the requirements for the concrete footings, including providing grade beams with specific dimensions, reinforcement details, concrete mix design, and related work such as saw cutting and hauling off spoils. It also includes exclusions and clarifications, such as not including work over 8" of existing concrete, permitting, or dumpsters/trash removal.
The RFI is a market survey to identify potentially qualified sources and their business size classifications. It requests information on company details, experience, business size, and socioeconomic status. Responses are due by November 27, 2024 at 12:00pm PDT and should be sent to the Contracting Officer and Contract Specialist. The requirement is for the Department of the Air Force Materiel Command Test Center.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF REQUIREMENTS (SOR)
Concrete Footings
Concrete Footers
Provide grade beams for shelters as follows:
• (4) EA footers 5’Wx3’Dx104’L
• (5) EA #5 bars top and bottom of footer with stirrups every 2’ on center.
• 4,000 psi concrete mix design.
• Includes saw cutting of existing slab and haul-off of spoils.
• Includes all form work, layout, placement and finishing.
• Assumed existing concrete is no more than 8” thick.
• Includes signed/sealed foundation engineering.
Exclusions/ Clarifications
Includes lifting equipment as required.
• Includes temp construction power as required.
• Saw cutting or demolition of any existing concrete over 8” thick.
• Laydown area required to assemble trusses with a clear path to building site.
• Final electrical connections to panel boxes, HVAC units and heaters is by others.
• Permitting and/or impact fees.
• Dumpsters/trash removal from site is specifically excluded.
• Site specific safety training is specifically excluded.
• Design fees of any kind unless otherwise stated.
• Abatement or testing of any kind.
• Geotechnical testing of any kind (may be required for foundation design and provided by others).
• Concrete testing.
• Underground utility locates.
• Overhead power lines must be 20’ away from the footprint of the shelter.