Solicitation_Plans_24B0008_Yazoo.pdf
PDF 4 MB Posted
- Solicitation number
- W912EE24B0008
About this file
This document is a set of solicitation plans for the Yazoo City Relief Well (N91) Replacement project in Yazoo County, Mississippi. The scope of work includes abandoning an existing relief well and installing a new 14-inch diameter replacement well, along with a new pump, motor, and underground electrical infrastructure.
The project is set aside for service-disabled veteran-owned small businesses and will be awarded as a firm-fixed price contract. The estimated contract value is between $250,000 and $500,000. The period of performance is 270 calendar days from the notice to proceed. The solicitation will be issued on May 21, 2024, with bids due by June 20, 2024 at 2:00 PM Central time. This procurement is being conducted under sealed bidding procedures, with the contract to be awarded to the lowest priced, responsive and responsible bidder.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-001
C O
VE
R
S H
EE
T
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D .W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
ISSUE DATE:
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
VICKSBURG DISTRICT
MAY 2024
W912EE-24-B0008
YAZOO COUNTY, MISSISSIPPI
YAZOO CITY RELIEF WELL (N91) REPLACEMENT
FC/MR&T, YAZOO RIVER BASIN
YAZOO CITY, MISSISSIPPI
Chief, Design Branch
COL, EN, District Engineer
APPROVAL RECOMMENDED BY:APPROVED BY:
Chief, Engineering & Construction Division
R/W
OHP
OHP
NEW POWERLINE
EXISTING POWER POLE
UNDERGROUND ELECTRIC
EXISTING HOUSING
PUMP TO BE INSTALLED
EXISTING POWERLINE
NEW POWER POLE
ROW LIMITS
BORING LOCATION
BENCHMARK
G-002
PR
O
JE
C
T
LO
C
AT
IO
N
M
AP
AN
D
IN
D
EX
T
O D
R
AW
IN
G
S
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ G
-0
.P ro je ct
M ap a nd
In de x to
D ra w in gs .d w g
:0
8:
A M
5/
/2
N
PROJECT LOCATION
GENERAL NOTES
LEGEND
1. AERIAL IMAGERY SHOWN WERE TAKEN IN 2019 UTILIZING BING SATELLITE
IMAGERY.
2. FOR INSTANCES WHERE SCALE IS NOT PROVIDED ON DRAWING OR DENOTED
WITH "N.T.S.", CONTRACTOR TO ASSUME DRAWING IS NOT TO SCALE.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING CONSTRUCTION LAY
DOWN AREA AS NEEDED FOR WORK.
4. EXISTING DRAINAGE SHALL NOT BE BLOCKED WITH EXCAVATED MATERIAL
DURING CONSTRUCTION.
5. HORIZONTAL CONTROL IS BASED ON MISSISSIPPI STATE PLANE COORDINATES,
WEST ZONE, USING NAD 83 DATUM. VERTICAL CONTROL IS BASED ON NAVD 88
DATUM.
6. ALL EXPOSED EXCAVATION, FILL, AND BACKFILL SLOPES SHALL RECEIVE
TOPSOIL, FERTILIZING, SEEDING, AND MULCHING. SLOPES THAT RECEIVE
RIPRAP SHALL NOT RECEIVE TOPSOIL, FERTILIZING, SEEDING, AND MULCHING.
INDEX TO DRAWINGS
Sheet Number Sheet Title
G-001 COVER SHEET
G-002 PROJECT LOCATION MAP AND INDEX TO DRAWINGS
G-401 GENERAL SITE LOCATION MAP
G-402 RIGHT OF WAY LIMITS
B-001 GEOTECHNICAL GENERAL NOTES AND LEGEND
B-101 BORING LOCATION
B-102 BORING PROFILE
C-101 SITE PLAN
C-501 STORMWATER POLLUTION AND PREVENTION PLAN
C-502 CONCRETE REINFORCEMENT AND TRENCH DETAIL
M-101 MECHANICAL PLAN AND SECTION
E-601 YAZOO CITY PUMPING STATION ELECTRICAL ONE LINE
A1 PROJECT LOCATION
SCALE: 1''= 250 MILES 250 MILES 500 MILES0
© 2023 Microsoft Corporation © 2023 TomTom
GENERAL SITE LOCATION
N: 1213071.54' E: 2263498.33'
HW
Y
H W
Y
G-401
G
EN
ER
AL
S
IT
E
LO
C
AT
IO
N
M
AP
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A1 GENERAL SITE LOCATION MAP
SCALE: 1"=1.5 MILES 1.5 MILES 3 MILES0
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ G
-4
.G en er al
S ite
L oc at io n M ap .d w g
:0
9:
A M
5/
/2
N
LEVEE ROAD
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W S57°37'00"W184.28'
S25°25'53"E
83.57'
N60°35'20"E
81.25'
S31°21'29"E
196.76'
ROW
N= 1212901.74 E= 2263500.73
ROW
N= 1213069.76 E= 2263398.34
ROW
N= 1213029.39 E= 2263328.67
ROW
N= 1213105.34 E= 2263291.67
ROW
N= 1213204.03 E= 2263447.29
ROW
N= 1212959.62 E= 2263594.69
N58°21'48"E
110.35'
N31°05'34"W 285.41'
R /W
R/WR/WR/W
R /W
R /W
R /W
R/W
R /W
R/W
R/WR/W
LDA - 1
N= 1213429.45 E= 2263176.34
LDA - 1
N= 1213515.73 E= 2263176.34
LDA - 1
N= 1213515.73 E= 2263311.26
LDA - 1
N= 1213714.50 E= 2263311.26
N
°0 0'
"E
9.
CONTRACTOR LAYDOWN AREA
LDA - 1
N= 1213714.97 E= 2263080.86
LDA - 1
N= 1213429.09 E= 2263083.34
N89°53'02"W
230.40'
R /W
R40.00'
R40 .00
LDA - 1
N= 1213520.39 E= 2263352.06
LDA - 1
N= 1213614.92 E= 2263352.63
G-402
R
IG
H T-
O F-
W
AY
D R
AW
IN
G
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ R
W -1
.R ig ht o f W ay L im its
.d w g
:0 9:
A
M
M ay
A1 RIGHT-OF-WAY DRAWING
SCALE: 1" = 40' 60' 120'0
1. CONTRACTOR SHALL RESTORE CONTRACTOR LAYDOWN AREA TO PRE-EXISTING
CONDITIONS AFTER CONSTRUCTION IS COMPLETE.
2. THE DESIGNATED LAYDOWN AREA IS SHARED WITH THE GOVERNMENT'S
OPERATION AND MAINTENANCE CONTRACTOR. THE RELIEF WELL CONTRACTOR
SHALL COORDINATE USE OF THIS AREA WITH THE COR.
GENERAL NOTES
B-001
G
EO
TE
C
H N
IC
AL
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ B.
Bo rin g Le ge nd
.d w g
:0 9:
A
M 5/
/2
Denotes location of consolidation test **
Denotes location of consolidated - drained direct shear test **
Denotes location of consolidated - undrained triaxial compression test **
Denotes location of unconsolidated - undrained triaxial compression test **
Denotes location of vane shear test **
Denotes location of sample subjected to consolidation test and each of the above three types of shear test **
FIGURES TO LEFT OF BORING UNDER COLUMNS "LL" AND "PL"
Denotes free waterFW
Are liquid limits and plastic limits, respectfully
Where underlined with a solid line denotes laboratory permeability in centimeters per second of undisturbed sample
Where underlined with a dashed line denotes laboratory permeability in centimeters per second of sample remoulded to the estimated natural void ratio
(Liquid Limit < 50)
(Liquid Limit > 50)
M or e th an h al f o f c oa rs e fra ct io n is la rg er th an
Amount of Fines)
(Little or No Fines)
(Little or No Fines) M or e th an h al f o f m at er ia l i s la rg er th an
N o.
s ie ve s iz e
When underlined denotes D size in mm *
M or e th an h al f o f c oa rs e
N o.
si ev e si ze fra ct io n is s m al le r t ha n N o.
s ie ve s iz e.
N o.
si ev e si ze M or e th an h al f o f t he m at er ia l i s sm al le r t ha n
In parenthesis are driving resistances in blows per foot determined with a standard split spoon sampler (1 38 " I.D., 2" O. D.) and a 140 lb. driving hammer with a 30" drop
* The D size of a soil is the grain diameter in millimeters of which 10% of the soil is finer, and 90% coarser than D .
** Results of these test are available for inspection in the U.S. Army Engineer District Office, if these symbols appear beside the boring logs on the drawings.
< 250
> 4000
FIGURES TO LEFT OF BORING UNDER COLUMN "W OR D "
NOTES:
Are natural water contents in percent dry weight
GRAVEL,Well Graded, gravel-sand mixtures, little or no fines
GRAVEL,Poorly Graded, gravel-sand mixtures, little or no fines
SILTY GRAVEL,gravel-sand-silt mixtures
CLAYEY GRAVEL, gravel-sand-clay mixtures
SAND, Well-Graded, gravely sands
SAND, Poorly-Graded, gravely sands
TYPICAL NAMES
UNIFIED SOIL CLASSIFICATION
SYMBOLS TO LEFT OF BORING
Ground - water surface and date observed
VS
T
Q
R
S
C
FIGURES TO RIGHT OF BORING
Are values of cohesion in lbs./sq. ft from unconfined compression test
SILTY SAND, sand-silt mixtures
CLAYEY SAND, sand-clay mixtures
SILT & very fine sand, silty or clayey fine sand or clayey silt with slight plasticity
LEAN CLAY; Sandy Clay; Silty Clay; of low to medium plasticity
ORGANIC SILTS and organic silty clays of low plasticity
SILT, fine sandy or silty soil with high plasticity
FAT CLAY, Inorganic clay of high plasticity
ORGANIC CLAYS of medium to high plasticity, organic silts
PEAT, and other highly organic soil
WOOD
GW
GP
GM
GC
SW
SP
SM
SC
ML
CL
OL
MH
CH
OH
Pt Wd
DESCRIPTIVE SYMBOLS
SYM
BOL
LETTER
SYMBOL
CLEAN
GRAVEL
CLEAN
SAND
SANDS
WITH FINES
SILTS AND
CLAYS
SILTS AND
HIGHLY ORGANIC SOILS
WOOD
NO SAMPLE
FI
N
E
G R
A
IN
E D
S O
IL
S
C O
A R
S E
G
R A
IN
E
D S
O
IL
S
G R
A V
E
LS
S A
N D
S
MAJOR DIVISION TYPE
GRAVEL
WITH FINES
(Appreciable
(Appreciable Amount of
Fines)
NOTE: Soils possessing characteristics of two groups are designated by combinations of group symbols
A comma will be used between modification symbols. Example. So,Gr,w/SIS,(CH)
CLAYS
CONSISTENCY
FOR COHESIVE SOILS
COLOR MODIFICATIONS MODIFICATIONS
GENERAL NOTES
10 10
0 20 40 60 80
OH
MH
CH
"U " L
INE
"A" L
INE
CL
CL - ML OL
ML
L. L. - LIQUID LIMIT
PLASTICITY CHART
For classification of fine - grained soils
P . I
P
LA
ST
IC
IT
Y
IN
D
EX
CONSISTENCY
VERY SOFT
SOFT
MEDIUM
STIFF
VERY STIFF
HARD
SYMBOLCOHESION IN LBS./SQ. FT. FROM
UNCONFINED COMPRESSION TEST
vSo
So
M
St vSt
H
2000 - 4000 1000 - 2000 500 - 1000 250 - 500
SYMBOLCOLOR
T
Y
R
BK
GR
lGr dGr
Br lBr dBr br Gr gy Br gn Gr gy Gn
Gn
Bl Bl Gn
Wh rd
Mot
SSIS
SISS
w/
D vD
Tr-
F
M
C cc rt lg sh sds slf
O
CS
SIS
SS
S
G
B
SL
Wd
Ox
Cr
Lo
Veg
MODIFICATION SYMBOLMODIFICATION
Sandy Silt strata
Silty Sand strata
With
Dense
Very Dense
Traces
Fine
Medium
Coarse
Concretions
Rootlets
Lignite fragments
Shale fragments
Sandstone fragments
Shell fragments
Organic matter
Clay strata or lenses
Silt strata or lenses
Sand strata or lenses
Sandy
Gravely
Boulders
Slickensides
Wood
Oxidized
Crumbly
Loose
Vegetation
REDDISH
MOTTLED
WHITE
BLUE - GREEN
BLUE
GREEN
GRAYISH - GREEN
GREENISH - GRAY
GRAYISH - BROWN
BROWNISH - GRAY
DARK BROWN
LIGHT BROWN
BROWN
DARK GRAY
LIGHT GRAY
GRAY
BLACK
RED
YELLOW
TAN
COLOR
SYMBOL
1. While the borings are representative of subsurface conditions at their respective locations and for their respective vertical reaches, local variations characteristic of the subsurface materials of the region are anticipated and, if encountered, such variations will not be considered as differing materially within the purview of the Contract Clause DIFFERING SITE CONDITIONS.
2. Ground water elevations shown on the boring logs represent ground water surfaces encountered in such borings on the dates shown. Absence of water surface data on certain borings indicates that no ground water data are available from the boring but does not necessarily mean that ground water will not be encountered at the locations or within the vertical reaches of such borings.
3. Consistency of cohesive soils shown on the boring logs is based on driller's log and visual examination and is approximate, except within those vertical reaches of the borings where shear strengths from unconfined compression test are shown.
4. The detailed explanation of the Unified Soil Classification System is presented in ASTM D 2487, (2017) Classification of Soils for Engineering Purposes.
YPS-1-23U
N= 1213082.733 E= 2263493.128
ELEV: 112.31
BORING LOCATION
B-101
BO
R
IN
G
L O
C
AT
IO
N
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ B-
1.
Bo rin g Lo ca tio n.
dw g
:0 9:
A
M
M ay
A1 BORING LOCATION MAP
SCALE: 1"=20' 20' 40'0
LEGENDLEGEND
NOTES
1. HISTORICAL BORING DATA IS PROVIDED ON SHEET B-102.
(20)
(27)
(16)
(17)
(30)
(27)
(37)
(50)
(36)
(27)
(37)
(86)
(46)
(89)
(48)
(64)
(59)
(59)
(28)
(17)
(50)
(52)
(42)
(61)
(50)
(50)
(15)
(33)
(14)
N-Value
CL
SM
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SM
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
USCS
LEAN CLAY (CL-ML); brown
SILTY SAND (SM); gray, moist, medium dense
POORLY GRADED SAND (SP); gray, wet, medium dense
POORLY GRADED SAND (SP); gray, moist, dense, trace silt
POORLY GRADED SAND (SP); gray, wet, medium dense
POORLY GRADED SAND (SP); gray, wet, dense
POORLY GRADED SAND (SP); gray, wet, medium dense
POORLY GRADED SAND (SP); gray, wet, dense
POORLY GRADED SAND (SP); gray, wet, very dense, lensed
POORLY GRADED SAND (SP); gray, wet, dense, trace
POORLY GRADED SAND (SP); gray, wet, very dense
POORLY GRADED SAND (SP); gray with black, wet, dense, lensed
SILTY SAND (SM); gray, wet, very dense, stratified
POORLY GRADED SAND WITH GRAVEL (SP); gray, wet, very dense
POORLY GRADED SAND (SP); gray, wet, very dense
POORLY GRADED SAND WITH GRAVEL (SP); gray, wet, medium dense, little fine to coarse gravel POORLY GRADED SAND WITH GRAVEL (SP); gray with black, wet, medium dense, few fine gravel POORLY GRADED SAND (SP); gray, wet, dense
POORLY GRADED SAND (SP); gray, wet, very dense
POORLY GRADED SAND (SP); gray, wet, dense
POORLY GRADED SAND (SP); gray, wet, very dense, few fine gravel
POORLY GRADED SAND WITH GRAVEL (SP); gray, wet, very dense, lensed, little fine to coarse gravel
POORLY GRADED SAND WITH GRAVEL (SP); gray, wet, medium dense, lensed, little fine to medium gravel POORLY GRADED SAND WITH GRAVEL (SP); gray to tan, wet, dense, little fine to coarse gravel POORLY GRADED SAND WITH GRAVEL (SP); gray, wet, medium dense, little fine to coarse gravel
Field Description
0.1374
D10
YPS-1-23U
Northing: 1213082.733 Easting: 2263493.128 Ground Level: 112.31
B-102
BO
R
IN
G
P R
O
FI
LE
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
1. BORINGS WERE ACCOMPLISHED IN 2023 BY ROTARY DRILLING METHOD WITH
MUD. UNDISTURBED SAMPLES WERE TAKEN WITH 3 INCH SHELBY TUBE.
LABORATORY TESTS WERE PERFORMED ON SELECTED SAMPLES.
2. ELEVATIONS SHOWN ARE BASED ON NAVD 88 DATUM.
NOTES
A1 BORING PROFILE
N.T.S.
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ B-
2.
Bo rin g Pr of ile
.d w g
:0 9:
A
M 5/
/2
EXISTING RAILROAD TRACKS
EXISTING RELIEF WELL (N-91)
TO BE GROUTED AND
ABANDONED
INSTALL NEW RELIEF WELL (N-24)
N= 1213077.697 E= 2263497.335
ELEV: 112.31
PERMANENT POWER
BURIED AND ROUTED TO EXISTING
WELL(S-91)
PP-4
PP-1
PP-3
PP-2
EXISTING RELIEF WELL (S-91)
DO NOT DISTURB
PP-5
BMBM YZPP-2
ELEV: 110.44
BM YZPP-1
ELEV: 111.88OHP
PERMANENT POWER
BURIED AND ROUTED
TO NEW WELL(N-24)
PP-7
PP-6
OHP NEW POWERLINE
UNDERGROUND ELECTRIC
EXISTING RELIEF WELL
RELIEF WELL TO BE
INSTALLED
EXISTING POWERLINE
POWER POLE
BORING LOCATION
C-101
SI
TE
P
LA
N
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ C
-1
.S ite
P la n.
dw g
:0 9:
A
M
M ay
TABULATION OF POWERPOLES
PP-1
PP-2
PP-3
PP-4
PP-5
WOOD POWER POLE
ITEM DESCRIPTION
1212968.64'
1213022.60'
1213105.87'
1213072.20'
1213241.80'
2263562.24'
2263637.01'
2263595.59'
2263538.85'
2263489.85'
NORTHING EASTING
WOOD POWER POLE
WOOD POWER POLE
WOOD POWER POLE
WOOD POWER POLE
E1 SITE PLAN
SCALE: 1"=25' 25' 50'0
NOTES
LEGEND
1. THE LOCATION AND SPACING OF EXISTING UTILITIES ARE APPROXIMATE.
CONTRACTOR SHALL VERIFY THE LOCATIONS OF UTILITIES PRIOR TO
CONSTRUCTION.
2. THE CONTRACTOR MUST MAINTAIN A SAFE CLEARANCE DISTANCE OF AT
LEAST 25 FEET FROM THE RAILROAD TRACK. THIS CLEARANCE INCLUDES THE
FULL SWING RADIUS OF THE EQUIPMENT WHETHER THE FULL SWING RADIUS IS
BEING USED OR NOT. IF A CONTRACTOR CANNOT MAINTAIN A CLEAR DISTANCE
OF 25 FEET FROM THE TRACK, A RIGHT OF ENTRY LICENSE AGREEMENT WITH
CN RAILROAD IS REQUIRED.
3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS
PRIOR TO CONSTRUCTION. IN ORDER TO ENSURE THE SAFETY OF ALL PARTIES,
THE CONTRACTOR SHALL CONTACT THE MISSISSIPPI ONE CALL SYSTEM
(1-800-227-6477) A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF
ANY EXCAVATION OR DEMOLITION ACTIVITY.
4. BRACING OF UTILITY POLES MAY BE REQUIRED WHEN TRENCHING OR
EXCAVATION IS IN CLOSE PROXIMITY TO THE POLES. THE CONTRACTOR IS
RESPONSIBLE FOR COST OF BRACING POLES. THERE IS NO SEPARATE PAY
ITEM FOR THIS WORK.
5. THE CONTRACTOR SHALL IMMEDIATELY REPAIR OR REPLACE ANY PHYSICAL
DAMAGE TO PRIVATE PROPERTY, INCLUDING, BUT NOT LIMITED TO FENCES,
WALLS, PAVEMENT, GRASS, TREES, AND ETC., AT NO ADDITIONAL COST TO THE
GOVERNMENT.
6. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO
THE ATTENTION OF THE GOVERNMENT BEFORE COMMENCING WORK.
DEVIATIONS FROM DESIGN SHALL NOT BE MADE WITHOUT PRIOR APPROVAL.
7. IT IS THE CONTRACTOR RESPONSIBILITY TO VERIFY ALL INFORMATION FOR
ACCURACY. EXISTING N-91 RELIEF WELL TO BE GROUTED IS APPROXIMATELY
10 FEET SHORTER IN LENGTH THAN THE NEW WELL (N-24) AND 14 INCHES IN
DIAMETER.
NOTES
LEGEND
TABULATION NOTES:
1. POWERPOLE IS TO REMAIN IN PLACE.
2. POWERPOLE TO BE INSTALLED WITH OVERHEAD POWER ROUTED FROM PP6.
3. POINT OF CONTACT (POC) FOR POWER: TODD LEVERETT (662)-571-5008.
OWNER SEE NOTE
YAZOO PUBLIC SERVICE COMMISSION 1,3
YAZOO PUBLIC SERVICE COMMISSION
YAZOO PUBLIC SERVICE COMMISSION
YAZOO PUBLIC SERVICE COMMISSION
YAZOO PUBLIC SERVICE COMMISSION
TABULATION OF BENCHMARKS
BM YZPP-1
BM YZPP-2
ITEM
1213199.46'
1213144.04'
2263464.20'
2263377.55'
NORTHING EASTING
TABULATION OF EXISTING RELIEF WELLS
(N91)
(S91)
ITEM
1213071.54' 2263498.33'
NORTHING EASTING
1213018.81' 2263530.96'
DISPOSITION
DO NOT DISTURB
GROUT AND ABANDON
PP-6 1213221.09' 2263386.55'WOOD POWER POLE YAZOO PUBLIC SERVICE COMMISSION
1,3
1,3
1,3
1,3
1,3
PP-7 1213160.69' 2263436.71'WOOD POWER POLE YAZOO PUBLIC SERVICE COMMISSION 2,3
111.88'
110.44'
ELEVATION
C-501
ST
O
R M
W
AT
ER
P
O
LL
U
TI
O N
AN
D
P R
EV
EN
TI
O
N P
LA
N
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ C
-5
.S W
PP
P
D et ai ls
.d w g
:1 0:
A
M 5/
/2
FL
O
W
NOTE:
POINTS A SHOULD BE HIGHER THAN POINT B.
A A
B
STEEL OR WOOD POST
(5' MIN. LENGTH)
FILTER FABRIC
ATTACH SECURELY TO UPSTREAM SIDE OF POST
(SILT FENCE 16" MIN. ABOVE GROUND AND 34"
MAX. ABOVE GROUND)
9" (MAX. RECOMMENDED)
STORAGE HEIGHT
3' (M
IN
2' (M
IN
4" X 4" TRENCH
EXCAVATE, LINE WITH FILTER FABRIC AS SHOWN,
AND BACKFILL WITH COMPACTED MATERIAL
RUNOFF
EXTRA STRENGTH SYNTHETIC FILTER FABRIC
REQUIRED IF WIRE MESH SUPPORT IS NOT USED
STEEL OR WOOD POST
10' MAX. SPACING WITH WOVEN WIRE SUPPORT FENCE
6' MAX. SPACING WITHOUT WIRE SUPPORT FENCE
FLOW
SEEDED THEN COMPACTED SOIL
2' (MIN.)
6' (MIN.)
1.
5'
(M
IN
FLOW
HARD SURFACE PUBLIC ROAD
COARSE AGGREGATE
50' (MIN.) LENGTH
AS REQUIRED WIDTH
6" (M
IN
D
EP
TH
A
A
VA
R
IE
S
(1 2"
O R
4"
FLOW
1.
5'
M
IN
SEE DITCH ELEVATION
FOR HEIGHT OF WATTLE ENDS
WATTLE (12" OR 24") TO BE
PLACED IN "U" SHAPE
WOOD STAKE AT TOE OF
SLOPE, BOTH SIDES
FLOW
WATTLE
B
A
NOTE:
POINTS A SHOULD BE HIGHER THAN POINT B.
A
EXISTING GROUND
WATTLE WOOD STAKE
ANCHOR THROUGH NETTING
DO NOT DAMAGE
DITCH BOTTOM
M1 SILT SCREEN FENCE- PLAN
SCALE: N.T.S.
L6 SILT SCREEN FENCE- ELEVATION
SCALE: N.T.S.
F1 HAY WATTLE- DITCH CHECK PLAN
SCALE: N.T.S.
B1 HAY WATTLE- DITCH ELEVATION
SCALE: N.T.S.
F10 TEMPORARY DIVERSION DIKE DETAIL
SCALE: N.T.S.
B14 CONSTRUCTION ENTRANCE AND EXIT DETAIL
SCALE: N.T.S.B8 HAY WATTLE SECTION A-A
SCALE: N.T.S.
L13 SILT SCREEN FENCE- SECTION
SCALE: N.T.S.
H14 SILT SCREEN FENCE- PERSPECTIVE
SCALE: N.T.S.
NOTES
1. INSPECT AND REPAIR BMP(S) AFTER EACH STORM EVENT AND REMOVE
SEDIMENT WHEN NECESSARY.
2. REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL NOT
CONTRIBUTE SEDIMENT OFF-SITE AND CAN BE PERMANENTLY STABILIZED.
3. SILT SCREEN FENCE, HAY WATTLES, AND ROCK CHECK DAMS SHALL BE
PLACED ALONG SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY.
4. THE ENVIRONMENTAL PROTECTION CONTROLS SHOWN IN THE CONTRACT
DRAWINGS MAY NOT FULLY ADDRESS ALL CONCERNS AND PERMIT
REQUIREMENTS, BUT ARE PROVIDED TO ESTABLISH A MINIMUM LEVEL OF
PROTECTION REQUIRED AT ALL TIMES. THE CONTRACTOR SHALL CONSIDER
HIS WORK OPERATIONS, METHODS, AND CURRENT SITE CONDITIONS TO
DEVELOP A COMPLETE PLAN, INCLUDING ADDITIONAL PROTECTION MEASURES
AS REQUIRED, TO ASSURE ADEQUATE PERFORMANCE AND COMPLIANCE WITH
ALL CONTRACT DOCUMENTS, REGULATIONS, AND PERMITS. REFERENCE
SECTION 01 57 20.00 09 ENVIRONMENTAL PROTECTION AND SECTION 01 57
23.00 09 STORM WATER POLLUTION PREVENTION PLAN FOR ADDITIONAL
REQUIREMENTS.
5. ANCHORING WOOD STAKES SHALL BE SIZED, SPACED, DRIVEN, AND BE OF A
MATERIAL THAT EFFECTIVELY SECURES THE CHECK. STAKE SPACING SHALL BE
A MAXIMUM OF THREE FEET. ALL NON-DEGRADABLE MATERIALS SHALL BE
REMOVED WHEN NO LONGER NEEDED.
6. TRENCHING OF WATTLES MAY BE NECESSARY IF PIPING BECOMES EVIDENT.
7. WATTLES SHOULD NOT BE USED IN HARD BOTTOM CHANNELS.
FLOW
9'
64''
CONCRETE REINFORCEMENT
REQUIRED. SEE NOTE 4 AND
SHEET M-101 FOR MORE
DETAILS.
6' ' S
AN
D
'' M
IN
3'' (TYP.)
BACKFILL MATERIAL
ELECTRICAL CABLE (IN CONDUIT)
GROUND LEVEL
EXISTING GROUND
SAND
BACKFILL MATERIAL
C-502
C O
N C
R
ET
E R
EI
N
FO
R
C
EM
EN
T
AN
D
T R
EN
C
H D
ET
AI
L
I.
BU
C
KN
ER
I.
BU
C
KN
ER
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
AP
R
IL
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
1. DEPTHS TO TOP OF THE CONDUIT MUST BE 24 INCHES BELOW
FINISH GRADE.
2. PROVIDE AT LEAST 3 INCHES CLEARANCE FROM THE CONDUIT TO
EACH SIDE OF TRENCH.
3. THE FIRST 6 INCH LAYER OF BACKFILL COVER MUST BE SAND. THE
REST OF THE EXCAVATION MUST BE BACKFILLED AND
COMPACTED IN 3 TO 6 INCH LAYERS.
4. SEE SPECIFICATION SECTION 03 30 00.00 09 FOR MORE DETAILS.
NOTES
LEGENDLEGEND
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
K7 CONCRETE PAD REINFORCEMENT DETAIL
SCALE: N.T.S.
A6 ELECTRICAL TRENCH
SCALE: N.T.S.
1" COMBINATION VACUUM
RELEASE & AIR VALVE
10" DIA x 48" L
SCHEDULE 40 STEEL
DISCHARGE PIPE
WELL CASING LID
CONCRETE PAD
(64" x 64" x 9")
FLOW
BOLT DOWN WELL CASING LID
SEE NOTE (4.)
6" DIA. BOLLARD
WELL CASING LID
UPPER SET
STEEL CASING
SCHEDULE 40
36" DIA x 15'-0" L
NEAT CEMENT BENTONITE
36" DIAMETER FOR FIRST 10'-0"
30" DIAMETER FOR REMAINDER
PUMP COLUMN PIPE
8" DIA x 90'-0" L PLUS BOWLS
SCHEDULE 80
STAINLESS STEEL PIPE
SEE SPECIFICATIONS
CONCRETE PAD
(64" x 64" x 9")
NATURAL GROUND
60 HP, 3 PHASE, 460V MOTOR
1" COMBINATION VACUUM
RELEASE & AIR VALVE
FLOW
SURFACE ELEVATION: 112.307 FT
50'-0" L PVC STANDPIPE,
2" DIA
50'-0" L PVC STANDPIPE,
2" DIA
3" MIN.
WELL RISER PIPE,
GRADE TP-304 STAINLESS STEEL,
SCHEDULE 40
60'-0" L X 14" DIA
30" DIA x 125-0" L WELL BORE, REVERSE CIRCULATORY
TOP OF WELL SCREEN
HI-FLOW, GRADE TP-304 SCREEN
#30 STAINLESS STEEL
60'-0" L X 14" DIA
BOTTOM OF WELL BORE,
125'-0" TOTAL BORE
14" DIAMETER TAILPIPE
STAINLESS STEEL
SCHEDULE 40
FILTER PACK
STARTS 36" FROM
END OF TAILPIPE
ENDS AT 125'-0" DEPTH
BOTTOM OF WELL SCREEN
VERTICAL TURBINE WELL PUMP,
1800 GPM AT 95'-0" TDH
8" DISCHARGE
LINESHAFT
BENTONITE PLUG
3'-0" L x 30" DIAMETER
FILTER PACK
30" DIAMETER
STARTS AT 50'-0" DEPTH END OF STANDPIPES
NEAT CEMENT BENTONITE
ENDS AT 47'-0" DEPTH
TY
P
6" TY
P
18"
TYP
FLOW
6" DIA STD. GALV.
STEEL PIPE FILLED W/
CONC. (APPLY TWO
COATS YELLOW PAINT)
MIN 0.188"WALL THK
6"
EXISTING
GROUND
CONCRETE
FOOTING
SLOPE CONC. BASE
18"
2"
M-101
M
EC
H
AN
IC
AL
P
LA
N A
N D
S
EC
TI
O
N
B.
G
R
IF
FI
N
, P .E
D . W
AL
LA
C E, P .E
AN
SI
D
W
2E E-
-B
VI
C
KS
BU
R G
, M S
AC
M
E
SE
C
TI
O N
VI
C
KS
BU
R G
D
IS
TR
IC
T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
P:
AC
M
E\ _P ro je ct s\
Ya zo o C ity P um pi ng P la nt
W el l R ep la ce m en t\0 5_
Sh ee ts a nd M od el s\ M
-1
.M ec ha ni ca l P la n an d
Se ct io n.
dw g
:1
0:
A M
5/
/2
WELL N-24 PUMP DISCHARGE PIPING - PLAN VIEW
SCALE: 3/4" = 1'-0"K11
1. COMBINATION VACUUM RELEASE & AIR VALVE SHALL BE 1" WITH IRON BODY AND
STAINLESS STEEL TRIM. VALVE SHALL PROVIDE THE FUNCTIONS OF BOTH AN AIR
RELEASE AND AN AIR/VACUUM VALVE. VALVE SHALL MEET THE REQUIREMENTS OF
AWWA C512.
2. VERTICAL TURBINE PUMP SHALL HAVE A MINIMUM PUMPING CAPACITY OF 1800 GPM
AGAINST 95 FT OF BOWL HEAD. PUMP SHALL HAVE A MINIMUM EFFICIENCY OF 80%.
ALL PUMP PARTS SHALL BE STAINLESS STEEL OR DESIGNED FOR EXTENDED
SUBMERSIBLE LIFE.
3. MOTOR SHALL BE 60 HP, 3 PHASE, 1775 RPM, 60 HZ, AND 460 V.
4. WELL CASING LID SHALL BE BOLTED DOWN USING A MINIMUM OF (6) 1" BOLTS WITH
NUTS AND WASHERS. CONTRACTOR RESPONSIBLE TO DESIGN WELL CASING LID TO
SUPPORT ALL VERTICAL LOADS.
PUMP - ELEVATION VIEW AND WELL N-24 DETAILS
SCALE: 1/2" = 1'-0"B3
M . A
U
LT
M
AN
M . A
U
LT
M
AN
AP
R
IL
PIPE BOLLARD LAYOUT - PLAN VIEW
SCALE: 3/4" = 1'-0"B11 PIPE BOLLARD DETAIL - SECTION VIEW
SCALE: 3/4" = 1'-0"B16
YA
ZO
O C
IT
Y, M
IS
SI
SS
IP
PI
FC
/M
R &T
, Y
AZ
O O
R
IV
ER
B
AS
IN
YA
ZO
O C
IT
Y
R
EL
IE
F
W
EL
L (N
) R
EP
LA
C
EM
EN
T
YA
ZO
O C
O U
N
TY
, M
IS
SI
SS
IP
PI
5-
0"
2'
-0
0'
-0
'-0
'-0
3' -0
2'
-0
NOTES
'-0
00 2' 4' 2'0 1' 4' 2'0 1' 4'
2'0 1' 4'
2'-6"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
A N
S I
D
Y A
Z O
O R
IV
E
R
F C
/M R
T
Y
A Z
O O
R
IV
E R
B A
S
IN
Y A
Z O
O C
IT
Y
R E
L
IE
F W
E L
L
N
R E
P L
A C
E M
E N
T
Y A
Z O
O C
O U
N T
Y M
IS
S
IS
S
IP
P
I
X X
X X
X X
-X X
-X -X
X X
X
N O
V
W X
X X
X X
-X X
-X -X
X X
V
IC
K S
B U
R G
M
S
A C
M E
S E
C T
IO
N
V
IC
K S
B U
R G
D
IS
T R
IC
T
K .H u ls e y
K .H u ls e y
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
B G ri ff in
D a v id
L W a ll a c e P
.E
60 HP
W E
L L
S -9
HO
100A
DISCONNECT
E-601
Y A
Z O
O C
IT
Y
P U
M P
IN
G
S T
A T
IO
N
E L
E C
T R
IC
A
L O
N E
L
IN
E
3 PHASE POWER LINE
SS
ELECTRICAL EQUIPMENT THAT IS TO BE REPLACED.
5. CONCTRACTOR TO COORDINATE WITH RBS FOR REMOVAL OF EXISTING S-91
WELL (S-91) MOTOR USING FLEX CONDUIT.
POWER WILL THEN BE RAN FROM THE NEW MOTOR STARTER TO THE EXISTING
OF THE EXISTING WELL (S-91) AND MOUNTED ON A UNISTRUT SUPPORT SYSTEM.
DISCONNECT SWITCH AND MOTOR STARTER SHALL BE LOCATED WITHIN 5 FEET
DISCONECT SWITCH AND MOTOR STARTER FOR EXISTING WELL (S-91). THE NEW
POWER SHALL BE RUN FROM THE EXISTING POWER POLE (PP-1) TO THE NEW
4. WORK TO BE COMPLETED FOR WELL S-91: NEW PERMANENT UNDERGROUND
MOTOR USING FLEX CONDUIT.
POWER WILL THEN BE RAN FROM THE NEW MOTOR STARTER TO NEW WELL (N-24)
A UNISTRUT SUPPORT SYSTEM LOCATED WITHIN 5 FEET OF THE NEW WELL (N-240.
WELL (N-24). THE DISCONNECT AND MOTOR STARTER SHALL BE MOUNTED ON
NEW POLE TO THE NEW DISCONNECT SWITCH AND MOTOR STARTER FOR NEW
BE INSTALLED (PP-7) AND UNDERGROUND POWER WILL BE RUN FROM THE
3. THE WORK TO BE COMPLETED FOR WELL N-24: A NEW POWER POLE WILL
INSTRUMENTATION AND CONTROL EQUIPMENT REQUIRED.
2. THE CONTRACTOR SHALL VERIFY ALL CONDUCTOR SIZES,
COORDINATE WITH THE UTILITY COMPANIES FOR POWERING OF THE SITE.
ASSOCIATED WITH THIS PROJECT. THE CONTRACTOR WILL ALSO
FROM THE SECONDARY OF THE MAIN TRANSFORMER TO ALL EQUIPMENT
1. CONTRACTOR IS RESPONSIBLE FOR THE POWER TO THE SITE
M
SS
HO
1 LINE DIAGRAM
MOTOR HP AS INDICATED ON ONE
HAND-OFF
UTILITY METER
FUSE
TYPE: SOLID STATE SOFT START
COMBONATION MAGNETIC STARTER
CIRCUIT BREAKER
120V
480V
120V INDICATES SECONDARY VOLTAGE.
TRANSFORMER, 480V INDICATES PRIMARY VOLTAGE,
ELECTRICAL SHEET LEGEND
NEMA 3R ENCLOSURE
NEMA SIZE 4
SOFT START
GENERAL ELECTRICAL NOTES
DISCONNECT
FUSIBLE
(3)
M
B Y
U T
IL
IT
Y
60 HP
W E
L L
N -2
HO
100A
DISCONNECT
LOCATED ON UTILITY POLE
UTILITY METERING
3 PHASE POWER LINE
SS
3- PHASE TRANSFORMER
UTILITY POLE MOUNTED
NEMA 3R ENCLOSURE
NEMA SIZE 4
SOFT START
208V
480V
D3
ONE-LINE DIAGRAM
SCALE: N.T.S.
WITHIN 5 FEET OF THE WELL
EQUIPMENT LOCATED
WITHIN 5 FEET OF THE WELL
EQUIPMENT LOCATED
W 2E
E- -B
AP
R
IL
| YAZOO CITY RELIEF WELL (N91) REPLACEMENT |
| Sheets and Views |
| G-001 COVER SHEET |
| Sheet 1 |
| G-002 PROJECT LOCATION MAP AND INDEX TO DRAWINGS |
| Sheet 1 |
| G-401 GENERAL SITE LOCATION MAP |
| Sheet 1 |
| G-402 RIGHT OF WAY LIMITS |
| Sheet 1 |
| B-001 GEOTECHNICAL GENERAL NOTES AND LEGEND |
| Sheet 1 |
| B-101 BORING LOCATION |
| Sheet 1 |
| B-102 BORING PROFILE |
| Sheet 1 |
| C-101 SITE PLAN |
| Sheet 1 |
| C-501 STORMWATER POLLUTION AND PREVENTION PLAN |
| Sheet 1 |
| C-502 CONCRETE REINFORCEMENT AND TRENCH DETAIL |
| Sheet 1 |
| M-101 MECHANICAL PLAN AND SECTION |
| Sheet 1 |
| 100%_YAZOO CITY RELIEF WELL (N91) REPLACEMENT_PLANS |
| E-601_ONE LINE AND LEGEND_04032024 |
File details come from the government source that posted it. Updated .