This document is a Sole Source Justification for a federal contract opportunity to procure modifications to an Agilent Model 8890A Gas Chromatograph. The estimated value is $52,267, with a period of performance from September 1, 2024 to December 31, 2024. The requirement includes specialized analytical hardware, software, installation, and training from the sole manufacturer, Custom Solutions Group. Market research could not be conducted as this is a custom solution. The contract is a new requirement, not a follow-on. The Government is issuing a Request for Quote (RFQ) under Solicitation #12405B24Q0284, with a NAICS code of 334516 (Analytical Laboratory Instrument Manufacturing). Quotes are due by July 23, 2024, and the basis for award is Lowest Price Technically Acceptable. The contracting agency is the USDA Agricultural Research Service, Southeast Area.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Specs document_Custom Solutions 2.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLE SOURCE JUSTIFICATION
MANDATORY TEMPLATE FOR FEDERAL PROCUREMENTS UNDER THE SIMPLIFIED ACQUISITION THRESHOLD
1. Estimated Dollar Value: $52,267.00
2. Anticipated Period of Performance: September 1st, 2024 – December 31st, 2024
3. Does the anticipated Period of Performance include option years? If no, explain.
No
4. Sources Sought Notice posted to Contract Opportunities and attached to this document?
☒ Yes ☐ No
5. Market Research conducted and attached to this document? If not, explain.
No Market Research could be conducted because this is custom equipment designed by a sole manufacturer.
6. Is this a new requirement or a follow-on to an expiring award?
☒ New requirement ☐ Follow-on to an expiring award
7. Describe the requirement. Please note that the requirement is the minimum acceptable specification or capability, and is not necessarily the best in the industry. Please note whether any additional follow-on work is anticipated in response to the current proposed effort.
The system features the analysis of trace nitrogen in balance helium and oxygen via Pulsed Discharge Helium Ionization Detector (PDHID).
The system also features the analysis of trace nitrous oxide (N2O) in balance helium and oxygen via Electron Capture Detector (ECD).
The sample is delivered directly from the incubation vessel as shown in Figure 2 of K. Butterbach-Bahl, G. Willibald, and H. Papen, “Soil core method for direct simultaneous determination of N2 and N2O emissions from forest soils.”
The sample must be at positive pressure to deliver a valid sample to the GC.
Multiple incubation vessels can be automated via Valco stream selector valve.
These items are required from Agilent
• G3540A, Agilent Model 8890A Gas Chromatograph, 120V
• G2785A, Side Pneumatics Compartment
• Option231, ECD with EPC
• Option301, 3-Channel Auxiliary EPC, two each
• M8413AA, Software, OpenLab CDS Workstation
• M8413AA, Option 002, Software, OpenLab CDS, GC Connection
GC2 Channel 1, Front PDHID
1. Supply and installation of auxiliary valve oven, capable of mounting six each Valco valves and multiple packed columns.
2. Supply and installation of all silcosteel sample wetted lines, where applicable.
3. Supply and installation of A3C4WE-TGA, pneumatically actuated, 4 port sample on/off valve, W Style, with Valcon E rotor rated to 75C and helium mass spectrometer leak test certification, mounted in the auxiliary valve oven.
4. Supply and installation of A3C10WE-TGA, pneumatically actuated, 10 port combination injection and backflush-to-vent valve, W Style, with Valcon E rotor rated to 75C and helium mass spectrometer leak test certification, mounted in the auxiliary valve oven.
5. Supply and installation of A3C6WE-TGA, pneumatically actuated, 6 port DeOxy valve, W Style, with Valcon E rotor rated to 75C and helium mass spectrometer leak test certification, mounted in the auxiliary valve oven.
6. Supply and installation of A3C4WE-TGA, pneumatically actuated, 4 port DeOxy regeneration valve, W Style, with Valcon E rotor rated to 75C and helium mass spectrometer leak test certification, mounted in the auxiliary valve oven.
7. Supply and installation of single valve oven for one valve.
8. Supply and installation of DOD, DeOxy Device. This device is used to eliminate oxygen interference for the analysis of trace argon, nitrogen, and krypton in balance oxygen. Includes DeOxy packed column mounted in small valve oven. Does not include 6 port DeOxy valve or 4 port DeOxy regeneration valve.
9. Supply and installation of the following packed columns: (1) one each 4' x 1/8" Silica Gel, 60/80 mesh, silcosteel, column oven mount, and (2) 10' x 1/8" Molecular Sieve 5A, 80/100 mesh, silcosteel, column oven mount.
10. Supply and installation of HPM, two each, miniature helium purifier, for secondary helium purification downstream of instrument carrier gas controls.
11. Supply and installation of D-3-I-8890, Valco Model D-3 Pulsed Discharge Helium Ionization Detector (PDHID), including: one each HP2 helium purifier for primary helium purification, one each Model PD-D3-I detector assembly, one each PDM2 pulse generator, and one each TGA-R-30F80P fixed restrictor discharge inlet tube.
12. Analytical Test GC. Analytical test GC includes optimization of injection volume, backflush timing, pneumatic and temperature programming, and detector settings. Functional test also includes a custom manual with valve plumbing diagram, example chromatograms, example chromatogram reports, precision statistics in triplicate, and the method itself.
GC2, Channel 2, Back ECD
13. Supply and installation of A3C10WE, pneumatically actuated, 10 port combination injection and backflush-to-vent valve, W Style, with Valcon E rotor rated to 200C, mounted in the auxiliary valve oven.
14. Supply and installation of the following packed columns: (1) two each 4’ x 1/8” HayeSep D, 80/100 mesh, silcosteel, mounted in the column oven.
15. Analytical Test GC. Analytical test GC includes optimization of injection volume, backflush timing, pneumatic and temperature programming, and detector settings. Functional test also includes a custom manual with valve plumbing diagram, example chromatograms, example chromatogram reports, precision statistics in triplicate, and the method itself.
GC2 Installation, Commissioning, and Training
16. Domestic on-site installation, commissioning, and training. Includes all domestic travel and site access costs.
GC1 and GC2 Windows Instrument Controller
17. Supply, installation, and implementation of Instrument Controller, HP Model Z4 G5, Windows 11 Pro, Intel Xeon W2423, 16GB SDRAM, 1TB Hard Drive, P203 20" Monitor, 3-Year Parts, Labor, On-Site Warranty
Estimated Freight, FOB Destination
18. Estimated freight, FOB Destin
Additional follow-on work is not anticipated.
8. List the proposed vendor and contact information.
Kerry Kreiling - kerry.kreiling@csg-labs.com Custom Solutions Group 1419 Avenue A, Katy , TX 77493 281-574-9999
9. Describe why the proposed vendor is the only vendor from which the requirement can be obtained. Examples of acceptable justifications include but are not limited to: sole manufacturer and seller, adherence to warranty provisions, urgency, etc. If other vendors can provide similar products or services, describe why they cannot meet our particular requirement.
SOLE SOURCE JUSTIFICATION
MANDATORY TEMPLATE FOR FEDERAL PROCUREMENTS UNDER THE SIMPLIFIED ACQUISITION THRESHOLD
Custom Solutions Group is the sole manufacturer and seller of the modifications to Agilent Gas Chromatographs.
Other vendors cannot meet our particular requirements because this is an add on to another project contracted through Custom Solutions Group.
10. Certification:
I hereby certify that the information provided above is accurate and complete to the best of my knowledge and belief.
Technical Representative Date
11. CO Certification:
I hereby determine that the circumstances of this procurement action deem only one source reasonably available. Also, the quoted price is determined to be fair and reasonable as documented on the SAP e-File Checklist and Award Summary.
Contracting Officer Date
12. Level Above the CO Approval:
I hereby determine that the circumstances of this procurement action deem only one source reasonably available. Also, the quoted price is determined to be fair and reasonable as documented on the SAP e-File Checklist and Award Summary.
Supervisory Contracting Officer Date
7/1/2024