Sol_140L4025Q0029.pdf
PDF 36 MB Posted
- Attached to
- 2025 PDO RANGE SUPPLY Federal contract opportunity
- Solicitation number
- 140L4025Q0029
About this file
This document is a Request for Quote (RFQ) for the Bureau of Land Management (BLM) New Mexico's 2025 Pecos District Office Range Supply Contract. The solicitation is a total small business set-aside under NAICS code 326122 for pipe, tube, and rigid tubing, with a size standard of 750 employees. BLM is seeking qualified vendors to provide supplies for multiple projects to construct and rebuild water systems and fences across southeastern New Mexico.
The contract includes a diverse range of materials such as polyethylene pipes, fittings, rubber tire drinkers, storage tanks, barbed and barbless wire, fence posts, solar pump systems, and associated hardware. Delivery will be to various locations including Circle F, Macho Cowboy, Deer Canyon, Azotea Mesa, and others. The solicitation closes on July 16, 2025, at 1:00 PM ET, with award to be made to the lowest-price technically acceptable offeror. Contractors must have an active SAM registration, provide detailed specification sheets, and demonstrate ability to deliver and offload materials at remote locations across unpaved rural New Mexico roads.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 2025_Price_Schedule_PDO_Range_Supply_Contract_v2_7-8-25_0001.xlsx | XLSX spreadsheet | |
| Sol_140L4025Q0029_Amd_0001.pdf | ||
| 2025_Delivery_Schedule_PDO_Supply_Contract_v2_7-8-25_0001.xlsx | XLSX spreadsheet | |
| B08_-_2025_Delivery_Schedule_PDO_Supply_140L4025Q0029.xlsx | XLSX spreadsheet | |
| B08_-_2025_Price_Schedule_PDO_Supply_Contract_04-14-25.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUMIS CHECKED
CODE 18a. PAYMENT WILL BE MADE BY
CODE
FACILITYCODE
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER
OFFEROR
LXA
SANTA FE NM 87508
301 DINOSAUR TRAIL
BLM NM-STATE OFC-SANTA FE(NM916)
0011276461 CODE 16. ADMINISTERED BYCODE
X
X
326122
SIZE STANDARD:
100.00 % FOR:SET ASIDE:UNRESTRICTED ORLXA
REQUEST FOR
PROPOSAL
(RFP)
INVITATION
FOR BID (IFB)
10. THIS ACQUISITION ISCODE
REQUEST FOR
QUOTE (RFQ)
14. METHOD OF SOLICITATION
13b. RATING
NORTH AMERICAN INDUSTRY
CLASSIFICATION STANDARD
(NAICS):
SMALL BUSINESS
07/16/2025 1300 ED
07/01/2025
0000000000Deronda Chevannes (No collect calls)
INFORMATION CALL:
FOR SOLICITATION 8. OFFER DUE DATE/LOCAL TIMEb. TELEPHONE NUMBER a. NAME
4. ORDER NUMBER3. AWARD/ 6. SOLICITATION
140L4025Q0029
5. SOLICITATION NUMBER
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS 1. REQUISITION NUMBER PAGE OF
1 5 0044018510OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30
TELEPHONE NO.
17a. CONTRACTOR/
CARLSBAD NM 88220-6292
620 E GREENE ST
BLM-NM CARLSBAD FIELD OFFICE*
15. DELIVER TO
SANTA FE NM 87508
301 DINOSAUR TRAIL
9. ISSUED BY
7.
2. CONTRACT NO.
EFFECTIVE DATE
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW
ISSUE DATE
DELIVERY FOR FREE ON BOARD
(FOB) DESTINATION UNLESS
BLOCK IS MARKED
11.
SEE SCHEDULEX
12. DISCOUNT TERMS THIS CONTRACT IS A RATED
ORDER UNDER THE DEFENSE
PRIORITIES AND ALLOCATIONS
SYSTEM - DPAS (15 CFR 700)
13a.
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
(SDVOSB)
HUBZONE SMALL
BUSINESS
8(A)
BLM NM-STATE OFC-SANTA FE(NM916)
WOMEN-OWNED SMALL
BUSINESS (WOSB)
ECONOMICALLY DISADVANTAGED
WOMEN-OWNED SMALL
BUSINESS (EDWOSB)
24.
AMOUNT
23.
UNIT PRICE
22.
UNIT
21.
QUANTITY
20.
SCHEDULE OF SUPPLIES/SERVICES
19.
ITEM NO.
Delivery: 11/30/2025 Period of Performance: 07/31/2025 to 11/30/2025
L24AS00180
00010 RFO Circle F Product/Service Code: 4710 Product/Service Description: PIPE, TUBE AND RIGID
TUBING
Continued ...
(Use Reverse and/or Attach Additional Sheets as Necessary)
HEREIN, IS ACCEPTED AS TO ITEMS:
X
XX
DATED
Ronald Shumate
. YOUR OFFER ON SOLICITATION (BLOCK 5),
INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE SET FORTH
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND DELIVER
ARE
ARE
31c. DATE SIGNED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA
31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (Type or print)
ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY ADDITIONAL
SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
27a. SOLICITATION INCORPORATES BY REFERENCE (FEDERAL ACQUISITION REGULATION) FAR 52.212-1, 52.212-4. FAR 52.212-3
AND 52.212-5 ARE ATTACHED. ADDENDA
26. TOTAL AWARD AMOUNT (For Government Use Only)
OFFER
STANDARD FORM 1449 (REV. 11/2021)
Prescribed by GSA - FAR (48 CFR) 53.212
ARE NOT ATTACHED.
ARE NOT ATTACHED.
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
30b. NAME AND TITLE OF SIGNER (Type or print)
30a. SIGNATURE OF OFFEROR/CONTRACTOR
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
25. ACCOUNTING AND APPROPRIATION DATA
29. AWARD OF CONTRACT: REFERENCE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE
32c. DATE 32b. SIGNATURE OF AUTHORIZED GOVERNMENT REPRESENTATIVE
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED:
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
40. PAID BY39. S/R VOUCHER NUMBER38. S/R ACCOUNT NUMBER
37. CHECK NUMBER
FINALPARTIAL
36. PAYMENT
FINALPARTIAL
35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER33. SHIP NUMBER
COMPLETE
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
42d. TOTAL CONTAINERS42c. DATE REC'D (YY/MM/DD)
42b. RECEIVED AT (Location)
42a. RECEIVED BY (Print)
41c. DATE41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
STANDARD FORM 1449 (REV. 11/2021) BACK
24.
AMOUNT
23.
UNIT PRICE
22.
UNIT
21.
QUANTITY
20.
SCHEDULE OF SUPPLIES/SERVICES
19.
ITEM NO.
L24AS00180
00020 RFO Macho Cowboy
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00030 RFO Lil Cowboy Draw
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00040 RFO Pierce 5 of 6
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
Continued ...
32f. TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT REPRESENTATIVE
5 2 of
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
NAME OF OFFEROR OR CONTRACTOR
3 5
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
140L4025Q0029
L24AS00180
00050 RFO Pierce 6 of 6
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00060 RFO Line Camp
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00070 RFO Pierce Water
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00080 RFO Pierce Lil Trap Water
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00090 CFO Airport
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
Continued ...
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Sponsored by GSA
FAR (48 CFR) 53.110
4 5
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
140L4025Q0029
00100 CFO Upper Segrest Draw
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00110 CFO Deer Canyon
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00120 CFO Acres Lake
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00130 CFO Salt Draw
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00140 CFO Upper Packsaddle
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00150 CFO Battle Axe
Product/Service Code: 4710
Continued ...
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
5 5
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
140L4025Q0029
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00160 CFO Azotea Mesa
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
L24AS00180
00170 CFO Box Canyon
Product/Service Code: 4710
Product/Service Description: PIPE, TUBE AND RIGID
TUBING
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Combined Synopsis – Range Supply Solicita on 140L4025Q0029
This is a combined synopsis/solicita on for commercial service prepared in accordance with the format in Federal Acquisi on Regula on (FAR) subpart 12.6, “Streamlined Procedures for Evalua on and Solicita on for Commercial Services,” as supplemented with addi onal informa on included in this no ce.
This solicita on is issued as a Request for Quote (RFQ). The solicita on document and incorporated provisions and clauses are those in effect through Federal Acquisi on Circular 2023-04 and are available in full text through Internet access at h p://www.acquisi on.gov/far.
This is a total small business set-aside under North American Industry Classifica on System (NAICS) 326122 – Fi ngs and unions, rigid plas cs pipe, manufacturing and Product Service Code (PSC) 4710 - Pipe, Tube and Rigid Tubing with a size standard of 750 employees.
The Bureau of Land Management (BLM), New Mexico, has a requirement supplies to be delivered to various sites in southeastern New Mexico for mul ple projects to be used to construct and rebuild water systems and fences. BLM is solici ng quotes on a compe ve basis for qualified vendors to enter a firm fixed price contract for supplies for the Pecos District Office. See the a ached Statement of Work/Specifica ons.
Award will be made to the offeror providing the lowest price technically acceptable.
Offerors must have an ac ve registra on in the System for Award Management (SAM) at h p://sam.gov.
Offers are being accepted by email at DChevannes@BLM.gov. Offerors must submit via email referencing Solicita on number 140L4025Q003 in the subject line and include the following:
1. Signed Solicitation and any amendments (if any)
a. Include Company Name
b. Point of Contact- Email and Phone Number
c. Unique Entity ID (UEI)
2. Acknowledge ability to meet all criteria from attached Statement of Work (SOW)
3. Ability of Item to Meet Required Specifications: To receive an "Acceptable" rating for this sub-factor, the offeror must demonstrate, at a minimum, that the proposed item meets or exceeds the required specifications.
a. Detailed Specification Sheet: In order to be considered for the award, the offeror must submit a detailed specification sheet for the product offered.
4. Specific acknowledgement of ability to access all locations for delivery to include any remote locations.
5. Specific acknowledgement of ability to offload order at all locations without government personnel or government equipment.
All ques ons concerning technical aspects of this project are due by July 7, 2024 by 1300 ET (Eastern Time)
The solicita on closes on July 16, 2025, at 1300 ET (Eastern Time).
All ques ons and offers should be submit via email to Deronda Chevannes, Contract Specialist (DChevannes@blm.gov)
2025 Pecos District Office (PDO)
RANGE SUPPLY
SPECIFICATIONS
1. GENERAL
The Bureau of Land Management has a requirement for supplies to be delivered to various sites in southeastern New Mexico for multiple projects to be used to construct and rebuild water systems and fences. Supplies to be as described in the Statement of Work, Delivery schedule and offload requirements at locations on maps. The materials shall meet, at a minimum, the following materials requirements.
2. MATERIALS
Line Item 1
Polyethylene (PE) Pipe and Fittings: Polyethylene pipe shall carry the seal of approval of the National Sanitation Foundation NSF-PW. Nominal diameters of pipe are outside dimensions for DR rated pipe.
All pipe shall be protected against damage by freezing, heat, sunlight, and traffic until delivered and accepted. DR-PR, Polyethylene pipe shall be type PE 4710 and meet ASTM D 3035 (Specifications for PE Plastic Pipe (DR PR) based on controlled outside diameter) and D3261 (Butt Heat fusion for PE Plastic Pipe) for DR rated pipe. SIDR-PR, Polyethylene pipe shall be type PE 4710 and meet ASTM D 2239 (Specifications for PE Plastic Pipe (SIDR-PR) based on controlled inside diameter) and D3261 (Butt Heat fusion for PE Plastic Pipe) for SIDR rated pipe. Pressure rating for DR and SIDR ratio of pipe shall be as shown on the Bid Schedule. Each roll of pipe shall be marked along its entire length with a tag that states the diameter, pressure rating, and DR/SIDR ratio. PE pipe shall be of the size and quantity shown in the Bid Schedule. All pipe rolls shall be bound in rolls and pipe ends shall be capped to exclude contaminate entry. In such an occasion as pipe delivery locations and amounts not being in even 2,000’ rolls, it is acceptable to deliver the remainder of pipe in rolled, bound, capped, and labeled remainder amounts.
Line Item 2
1.25” Transition threaded male Butt Fusion, DR-9 stainless steel. Polyethylene (PE) Pipe and Fittings:
Polyethylene pipe shall carry the seal of approval of the National Sanitation Foundation NSF-PW.
Nominal diameters of pipe are outside dimensions for DR rated pipe. All pipe shall be protected against damage by freezing, heat, sunlight, and traffic until delivered and accepted. Polyethylene pipe shall be type PE 4710 and meet ASTM D 3035 (Specifications for PE Plastic Pipe (DR PR) based on controlled outside diameter) and D3261 (Butt Heat fusion for PE Plastic Pipe) for DR rated pipe.
Pressure rating for DR ratio of pipe shall be as shown on the Bid Schedule.
Line Item 3
1.25” Ell, 90 degree elbow Butt Fusion. Polyethylene (PE) Pipe and Fittings: Polyethylene pipe shall carry the seal of approval of the National Sanitation Foundation NSF-PW. Nominal diameters of pipe are outside dimensions for DR rated pipe. All pipe shall be protected against damage by freezing, heat, sunlight, and traffic until delivered and accepted. Polyethylene pipe shall be type PE 4710 and meet ASTM D 3035 (Specifications for PE Plastic Pipe (DR PR) based on controlled outside diameter) and D3261 (Butt Heat fusion for PE Plastic Pipe) for DR rated pipe. Pressure rating for DR ratio of pipe shall be as shown on the Bid Schedule.
Line Item 4
Rubber Tire Drinker (RTD) ~8' diameter rubber tire trough, 22.5" max height ~500 gallon. A single 65/45-45 L-5 Loader-Dozer tire cut through the center of the 45” tread will make two of these 8’ rubber tire drinkers.
Rubber Tire Drinker (RTD) ~12' diameter rubber tire trough, 25" max height ~750 gallon. 40.00R57 or 46.90R57 tires or equivalent are acceptable.
Thoroughly clean and rinse heavy equipment tires used as troughs, as they may be contaminated with chemicals such as ethylene glycol or calcium chloride. Only tires without aftermarket chemical puncture sealer shall be provided. Tires must be capable of holding water and all holes shall be patched in a method acceptable for 10 years of use without tire water holding failure upon delivery.
Line Item 5
1.25” Flippen design float valve heavy duty assembly. High capacity valve that can be tank wall mounted. Inlet side has a machined flange and is NPT pipe threaded for inlet connection. Bronze body with female NPT inlet-open outlet. Suitable to work with maximum inlet pressure of 165 psi. Includes 12” stem rod with thumb screw, hooks, swivel joint, and stem threaded 3/8”-16 at one end all brass.
Includes 8” plastic ball float that is resistant to corrosion and sunlight deterioration.
Line Item 6, 7, and 8
Storages for water. Prefabricated polyethylene tanks shall meet standards and regulations ASTM D1998-06, standard Specifications for Polyethylene Upright Storage tanks; NSF/ANSI Standard 61;
and FDA Regulation 21 CFR 177.152. The tank must also be designed to prevent UV damage and algae growth. The tank must be designed to handle liquid with a specific gravity of 1.1 or greater. All storages must have a graduated scale on the side of the storage to determine capacity. All storage tanks shall have at a minimum two (2) 1.25” bulkhead fitting with threaded plugs, PVC or PE plugs are acceptable. One bulkhead fitting shall be installed at the top of the tank in the manhole assembly and capable of being used as an overflow. The second bulkhead fitting shall be installed at the bottom outside edge of the tank under the manhole. All tanks shall be furnished with a screw in lid for the manhole cover. All tanks must be tan, beige, or brown in color with ribbed sides and reinforced X design tops with lifting eyelets for strength and durability as good as or better than Enduraplas tank manufacturing.
Line Item 10
Barbed Wire spec.: A strand of two 12-1/2-ga galvanized wires twisted together with 2-point barbs of 14-gauge wire spaced 4” apart. Wire and barbs shall be zinc-coated steel, with a zinc coating of at least 0.28 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbed wire shall conform to ASTM A 121, class 1, and come in 1320’ spools.
Line Item 11
Barbless Wire spec: A strand of two 12-1/2 gauge, galvanized wires twisted together. Wire shall be zinc coated steel wire of at least 0.28 oz per square foot of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbless wire shall conform to ASTM A
121, class 1, and come in 1320’ spools.
Line Item 12
Upright Post Steel Angle Iron: Uprights shall consist of angles with a nominal size 2 ½” by 2 ½” by ¼” weighing approximately 4.10 lb/ft prior to fabrication. Total length shall be 7’ per post. Uprights shall be furnished with the necessary holes and galvanized hardware for the required assembly (See section 2. MATERIALS F. Fasteners). All posts shall be cleaned of all loose scale prior to finishing and painted solid green (Federal Standard 595B with one or more coats of weather resistant, air drying or baking paint or enamel. The steel posts shall be in conformance with ASTM, "Specification for Steel Fence Posts and Assemblies, Hot Wrought," ASTM A36/A36M.
Line Item 13
Brace Post Steel Angle Iron: Braces shall consist of angles nominal size 2” by 2” by ¼” weighing approximately 3.19 lb/ft prior to fabrication. Total length shall be 7’ per post. Braces shall be furnished with the necessary holes and galvanized hardware for the required assembly (See section 2.
MATERIALS F. Fasteners). All posts shall be cleaned of all loose scale prior to finishing and painted solid green (Federal Standard 595B with one or more coats of weather resistant, air drying or baking paint or enamel. The steel posts shall be in conformance with ASTM, "Specification for Steel Fence Posts and Assemblies, Hot Wrought," ASTM A36/A36M.
Line Item 14
Fasteners: 0.50” Nuts, and 0.50 by 1.5” bolts. All bolts and nuts shall conform to grade 5 ASME B 18 2 1, ASME B 18 2 2, and ASME B 18 21 1 respectively.
Line Item 15
Wire Fence Stays: 36” twisted wire fence stays manufactured from smooth galvanized 9-1/2 ga (minimum) wire. ASTM A 121.
Line Item 16
Steel Fence SPEC. Posts certified according to ASTM A 702-89 (2006) part 13.1: 5’6” steel fence posts, 8” silver painted top or green top with the remainder being green “T” bar type, with a welded or riveted anchor plate. Furnish with 4 clips per post clip-type wire fasteners (punched tabs for fastening wires are not acceptable). Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall have a minimum weight of 1.33 lb/linear ft. The anchor plates shall weigh a minimum of 0.67 pounds +5 percent and be a minimum of 18 square inches in area. The steel fence posts shall conform to ASTM A 702.
Line Item 17
Sacked ready mix Concrete: 80 lbs. sacks ASTM C387.
Line Item 18
Solar Pump Grundfos 6SQF2, or equivalent, submersible motor/pump unit: Motor/Pump unit shall be AC/DC multistage, helical type, brushless motor, capable of operating as per specifications stated in work data.
1. Pump and motor materials exposed to water shall be corrosion resistant and require a minimum of maintenance for a 10 year period or more.
2. The pump shall be internally threaded and have a built-in check valve and pump inlet screen.
3. Pump shall have dry-running and overload protection.
4. Pump shall have over and under voltage protection with a wide voltage range.
5. Pump shall have a high efficiency permanent-magnetic motor (PM motor) with maximum power point tracking (MPPT).
Line Item 19
General: PV Pumping System shall meet the requirements of the NEC articles 690 and all other applicable articles to ensure installer/operator safety. Equipment shall be UL listed where available. All equipment and conductors shall be capable of operating in temperatures of 0oF to 120oF. PV pumping system shall also include the following:
1. A manual electrical disconnect (safety switch) that shuts off power from the
PV Power Supply designed to be attached to the array support pole above or below the pump controller.
2. Furnish grounding rod, wire, and attachments according to the NEC articles
250 and 690.
B. Photovoltaic Power Supply: Power supply shall be complete with PV array, mounting structure, controller, and any balance of system hardware and conductors required for “above ground” installation. The power supply shall be sized by supplier and be capable of supplying the pump controller proper current and voltage to pump from 350 feet of depth, anticipated wattage is 680.
1. Photovoltaic modules shall be UL listed and include a minimum 10-year 90% power rating warranty.
2. Bypass diodes shall be installed in modules according to module manufacturers’ requirements.
3. Power supplies must display hazard-warning signs where there is a high voltage danger to the installer/operator.
4. Controller shall be designed to work specifically with manufacturers motor/pump unit. Controller shall include hardware required to mount directly to array support pole and shall be in a rain tight NEMA enclosure. Controller shall include on/off switch and wired connection for a generator sufficient to run the pump as a back-up.
6. Module interconnections and output shall be sunlight resistant cable or in flexible conduit.
Line Item 20
3 Panel pole mount kit. Module support structures shall mount on top of a 4 inch nominal pipe size SCH 40 steel pipe. Modules must be able to withstand a minimum wind load of 100 mph.
Line Item 21
Control wire kit. Controller shall be designed to work specifically with manufacturers motor/pump unit.
Controller shall include hardware required to mount directly to array support pole and shall be in a rain tight NEMA enclosure. Controller shall include on/off switch and wired connection for a generator sufficient to run the pump as a back-up. Electrical generator plug and 20 feet of wire to be compatible with typical generator sufficient to operate the pump shall be supplied.
Line Item 22
IO 101-115V switchbox interface, or compatible equal, which will allow pump to operate with solar and generator capabilities.
Line Item 23
8/3 Flat double jacket PVC pump wire. The power supply shall be sized by supplier and be capable of supplying the pump controller proper current and voltage. Drop cable safety/rope is required to connect pump to PV system, to be sized by supplier. Safety rope appropriate to pull the drop pipe and pump in case of emergency or failure of drop pipe.
Line Item 24
Drop Pipe will be threaded schedule 120 PVC in 20’ lengths and shall be complete with 1.00” stainless steel drop pipe couplings. Threaded pipe requires a 50% reduction in the pressure ratings stated, therefore the pressure rating is reduced from 600 psi to 300 psi at 73 degrees Fahrenheit in threaded pipe. Shall conform to ASTM D1785-12.
Line Item 25
1.00” (1”) Mpt NPT (tapered threads) stainless steel drop pipe couplings for submersible well. Shall conform to ASTM A312/A312-14b.
3. DELIVERY NOTIFICATION
The Contractor shall notify the COR (Contracting Officer's Representative) at least 10 working days prior to delivery, to arrange for inspection and acceptance at destinations.
4. DELIVERY TIMES
Delivery shall be made between the hours of 8:30 a.m. and 3:30 p.m., Monday through Friday, Federal Holidays excluded.
5. RESPONSIBILITY FOR UNLOADING AT DESTINATIONS
a. The Contractor shall be responsible for unloading at destinations cited below and the contractor is responsible for the cost of unloading.
b. The Contractor shall load and unload products in such a manner that protects them from damage until accepted by the Contracting Officer.
6. TRANSPORTATION/FREIGHT CHARGES
All costs of transportation/freight, from shipping points to the destinations shall be paid by the Contractor and included in his unit price quoted for the items.
7. DELIVERY DESTINATIONS
a. Some destinations are off of improved road surfaces in rural New Mexico, such as on caliche, gravel, dirt, or sand.)
***IMPORTANT NOTES***
Must be able to provide all line items to specification. No partial orders. All or None.
Contractor shall be responsible for unloading at all destinations. Any cost associated with unloading must be incorporated in line-item pricing.
Must delivery to destinations that are in rural New Mexico, with roads that are unpaved such as on caliche, gravel, dirt, or sand.
Pecos District Office (PDO) Range Supply
140L4025Q0029
Evaluation Criteria
Lowest Price Technically Acceptable (LPTA) The Government intends to award a Firm Fixed Price (FFP) contract to a responsible party whose quote is responsive to the solicitation and provides “Best Value to the Government” on a Lowest Priced Technically Acceptable (LPTA) basis.
A technical Evaluation Panel consisting of no less than three members will conduct the initial evaluation.
Upon completion of the evaluation period, the panel will review each proposal and make their final award recommendation to the Contracting Officer.
Submission Requirements:
Provide your bid in two separate volumes:
Volume 1 – Pricing, Volume 2 – Non-pricing, which includes information related to the evaluation factors below.
All evaluation factors other than price, when combined will be weighted equally. The evaluation factors listed below will be used to select the contractor that offers LPTA offer.
FACTOR #1 – Price
The offeror shall provide detailed pricing information for the required items in the statement of work.
To be considered for award, offerors must achieve an "Acceptable" rating in all non-price factors/sub-factors.
Evaluation Criteria (Non-Price Factors):
FACTOR #2 – Technically Acceptable
1. All criteria from attached Statement of Work (SOW) are met
2. Ability of Item to Meet Required Specifications: To receive an "Acceptable" rating for this sub-factor, the offeror must demonstrate, at a minimum, that the proposed item meets or exceeds the required specifications.
a. Detailed Specification Sheet: In order to be considered for the award, the offeror must submit a detailed specification sheet for the product offered.
3. Specific acknowledgement of ability to access all locations for delivery to include any remote locations.
4. Specific acknowledgement of ability to offload order at all locations without government personnel or government equipment.
DELIVERY SCHEDULE BY LOCATION
CFO Justin Wilson (Airport 78075) Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 2000 Foot 3 1.25" 90 ELL, DR-9 fusion 1 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 1 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 1 Each 6 3,100 gallon PE storage (tan in color) 103" wide x 100" tall (8.7' wide by 8.33' tall) 2 Each
17 Sacked Ready Mix Concrete (42/pallet) 42 Each
CFO Jennett Kelley (Upper Segrest Draw 79048) Line Item Description Quantity Units
6 3,100 gallon PE storage (tan in color) 103" wide x 100" tall (8.7' wide by 8.33' tall) 3 Each
CFO Denny Bernett (Deer Canyon) Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 40000 Foot 3 1.25" 90 ELL, DR-9 fusion 6 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 6 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 6 Each 7 5,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 7.33' tall) 7 Each
17 Sacked Ready Mix Concrete (42/pallet) 252 Each
CFO Mike Bennet Acres Lake Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 3200 Foot 3 1.25" 90 ELL, DR-9 fusion 1 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 1 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 1 Each 7 5,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 7.33' tall) 2 Each
17 Sacked Ready Mix Concrete (42/pallet) 42 Each
CFO Chris Hamil Salt Draw Fence Line Item Description Quantity Units
10 Barbed Wire Fence 15 Rolls 11 Barbless Wire Fence 5 Each 12 Upright Post 7 Each 13 Brace Post 12 Each 14 Nut, and bolt 9 Each 15 Twisted Wire Stays 36", 100 count bundles 5 bundle 16 5.5' SPEC T-Posts white top 414 Each 17 Sacked Ready Mix Concrete (42/pallet) 16 Each
CFO Upper Packsaddle Pipeline (79049) Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 8000 Foot
CFO Battle Axe Road Fence (76037) Line Item Description Quantity Units
10 Barbed Wire Fence 38 Rolls 11 Barbless Wire Fence 13 Each 12 Upright Post 18 Each 13 Brace Post 36 Each 14 Nut, and bolt 18 Each 15 Twisted Wire Stays 36", 100 count bundles 13 bundle 16 5.5' SPEC T-Posts white top 1039 Each 17 Sacked Ready Mix Concrete (42/pallet) 42 Each
CFO Jim Marbach (Azotea Mesa 78080) Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 24000 Foot 4 8' rubber tire trough, 22.5" max height ~500 gallons 5 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 5 Each 6 3,100 gallon PE storage (tan in color) 103" wide x 100" tall (8.7' wide by 8.33' tall) 0 Each 7 5,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 7.33' tall) 5 Each
17 Sacked Ready Mix Concrete (42/pallet) 210 Each 18 Solar Pump Grundfos 6SQF2 1 Each 19 Solar Panel 340 watt 2 Each 20 3 panel pole mount 1 Each 21 control wire kit 1 Each 22 101-115V Interface 1 Each 23 8/3 Flat Double Jacket PVC pump wire 350 Feet 24 1" PVC pipe schedule 120, 20' lengths 320 Feet 25 1" stainless steel drop pipe couplers 16 Each
CFO Cox Waters (78062) Line Item Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 10000 Foot 4 8' rubber tire trough, 22.5" max height ~500 gallons 2 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 2 Each
17 Sacked Ready Mix Concrete (42/pallet) 84 Each
2024 RFO Circle F Supply
Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 10,560 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 7 Each 3 1.25" 90 ELL, DR-9 fusion 4 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 2 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 2 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 1 Each 9 Valve Box, 24" length by 24" diameter riser and septic lid 2 Each
17 Sacked Ready Mix Concrete (42/pallet) 84 Each
2024 RFO Macho Cowboy Supply Line Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 200 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 4 Each 3 1.25" 90 ELL, DR-9 fusion 4 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 2 Each
2024 RFO Little Cowboy Draw Supply Line Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 200 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 4 Each 3 1.25" 90 ELL, DR-9 fusion 4 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 1 Each
2024 RFO Pierce Fence Replacement 5 of 6 Line Item
Description Quantity Units
10 Barbed Wire Fence 4 Each 11 Barbless Wire Fence 2 Rolls 12 Upright Post 5 Rolls 13 Brace Post 6 Each 14 Nut, and bolt 6 Each 15 Twisted Wire Stays 36", 100 count bundles 1 Each 16 5.5' SPEC T-Posts white top 83 Bundle 17 Sacked Ready Mix Concrete (42/pallet) 42 Each
2024 RFO Pierce Fence Replacement 6 of 6
Item
Description Quantity Units
10 Barbed Wire Fence 6 Each 11 Barbless Wire Fence 2 Rolls 12 Upright Post 2 Rolls 13 Brace Post 4 Each 14 Nut, and bolt 4 Each 15 Twisted Wire Stays 36", 100 count bundles 2 Each 16 5.5' SPEC T-Posts white top 164 Bundle 17 Sacked Ready Mix Concrete (42/pallet) 26 Each
2024 RFO Line Camp Supply (Sultimeir) Line Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 10960 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 7 Each 3 1.25" 90 ELL, DR-9 fusion 5 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 1 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 1 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 1 Each 9 Valve Box, 24" length by 24" diameter riser and septic lid 1 Each
17 Sacked Ready Mix Concrete (42/pallet) 42 Each
2024 RFO Pierce Water Development Line Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 8600 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 8 Each 3 1.25" 90 ELL, DR-9 fusion 4 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 2 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 2 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 2 Each
17 Sacked Ready Mix Concrete (42/pallet) 84 Each
2024 RFO Pierce Water Development Little Trap pipeline Line Item
Description Quantity Units
1 DR-9 250 psi 1.25" PE pipe (2,000' rolls) 600 Foot 2 1.25" threaded male fusion transition, DR-11 200 psi 4 Each 3 1.25" 90 ELL, DR-9 fusion 2 Each 4 8' rubber tire trough, 22.5" max height ~500 gallons 1 Each 5 1.25" Flippen float valve assembly, complete with ball, swivel, and arm. 1 Each 8 10,000 gallon PE storage (green in color) 142" wide x 88" tall (11.83' wide by 11.83') tall) 1 Each
17 Sacked Ready Mix Concrete (42/pallet) 42 Each
Designation: A 121 – 99 (Reapproved 2004)
Standard Specification for Metallic-Coated Carbon Steel Barbed Wire 1
This standard is issued under the fixed designation A 121; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This specification covers metallic-coated steel barbed
wire, consisting of a strand of two wires.
1.2 The barbed wire is available with aluminum, zinc, and
zinc-5 % aluminum-mischmetal alloy coatings, with a number of coating weights, in a number of different constructions (designs), and in two grades. Not all designs are available in all coating types.
1.3 The values stated in inch-pound units are to be regarded
as the standard. The values given in brackets are for informa-tion only.
1.4 The text of this specification references notes and
footnotes that provide explanatory information. These notes and footnotes (excluding those in tables) shall not be consid-ered as requirements of the specification.
2. Referenced Documents
2.1 ASTM Standards:2
A 90/A 90M Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings
A 428/A 428M Test Method for Weight of Coating on Aluminum-Coated Iron or Steel Articles
A 641/A 641M Specification for Zinc-Coated (Galvanized) Carbon Steel Wire
A 700 Practices for Packaging, Marking, and Loading Methods for Steel Products for Domestic Shipment
A 809 Specification for Aluminum-Coated (Aluminized) Carbon Steel Wire
A 856/A 856M Specification for Zinc-5 % Aluminum- Mischmetal Alloy-Coated Carbon Steel Wire
A 902 Terminology Relating to Metallic Coated Steel Prod-ucts
2.2 Federal Standard:
Fed. Std. No. 123 Marking for Shipments (Civil Agencies)3
2.3 Military Standards:
MIL-STD-129 Marking for Shipment and Storage3
MIL-STD-163 Steel Mill Products Preparation for Ship-ment and Storage3
3. Terminology
3.1 Definitions—For definitions of terms used in this speci-
fication, refer to Terminology A 902.
4. Classification
4.1 The barbed wire covered by this specification is classi-
fied as described in this section.
4.2 Design Number—Numbers describing standard sizes
and constructions, as listed in Table 1.
4.3 Metallic Coating Type:
4.3.1 Coating Type A—Made from aluminum-coated strand
wire.
4.3.2 Coating Type Z—Made from zinc-coated strand wire.
4.3.3 Coating Type ZA—Made from zinc-5 % aluminum-
mischmetal alloy (Zn-5AL-MM) coated strand wire.
4.4 Metallic Coating Class—The specified amount of coat-
ing (coating weight [mass]) on the strand wire.
4.4.1 For Coating Type A, see 6.3. (Only one coating weight
for each wire size.)
4.4.2 For Coating Type Z, see Table 2.
4.4.3 For Coating Type AZ, see Table 3.
4.5 Grades:
4.5.1 Standard Grade—Barbs spaced on 4 or 5-in. [102 or
127-mm] centers as indicated in Table 1.
4.5.2 High-Security Grade—Barbs spaced on 3-in. [76-mm]
centers (for Coating Type A only).
NOTE 1—The design numbers are related to the characteristics of the construction of the barbed wire, with the number groups related, in order, to the steel wire gage of the strand wires, number of barb points, spacing of barbs, steel wire gage of the barbs, and a letter indicating the shape of the barbs.
1 This specification is under the jurisdiction of ASTM Committee A05 on Metallic-Coated Iron and Steel Products and is the direct responsibility of Subcommittee A05.12 on Wire Specifications.
Current edition approved May 1, 2004. Published June 2004. Originally approved in 1928. Last previous edition approved in 1999 as A 121 - 99.
2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. ForAnnual Book of ASTM Standardsvolume information, refer to the standard’s Document Summary page on the ASTM website.
3 Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
5. Ordering Information
5.1 Orders for material under this specification shall include the following information, as necessary to describe the desired product.
5.1.1 Name of material (steel barbed wire),
5.1.2 Quantity (number of spools and length of barbed wire
on each, or total length) (see 7.5 for standard size of spools),
5.1.3 Metallic coating type (see 4.3),
5.1.4 Metallic coating class (for Types Z and ZA) (see Table
2 or Table 3),
5.1.5 Design Number (see Table 1),
5.1.6 For Coating Type A barbed wire, whether aluminum
alloy barbs are required or prohibited (see 6.2.1). If not stated, the choice shall be at the manufacturer’s option,
5.1.7 ASTM designation and year of issue, and
5.1.8 Certification or test report, or both, if required.
NOTE 2—A typical ordering description is as follows: Steel barbed wire, 20 spools of 80 rods each, Coating Type Z, Coating Class 3, Design Number 12-2-4-14R, to ASTM Specification A 121-99, with certification.
5.2 All spools of barbed wire accepted by the purchaser
shall be billed on the basis of the original length of the spools before sampling, unless changed by contractual agreement.
6. Material
6.1 Base Metal—The base metal of the steel strand wires
and steel barbs shall be of good commercial quality carbon steel, capable of meeting the breaking strength requirement in
7.7. The base metal for aluminum barbs (permitted with
metallic Coating Type A) shall be aluminum alloy wire conforming to Alloy 5000-H38, Alloy 6061-T94, or equal.
6.1.1 For Coating Type A barbed wire, the choice of whether
aluminum-coated steel wire or aluminum alloy wire for the barbs shall be that of the manufacturer, unless otherwise specified by the purchaser. If aluminum alloy wire is used, the particular alloy shall be agreed upon between the manufacturer and the purchaser at the time the order is placed.
6.2 Coating Materials—The coating on the wire shall con-
form with the requirements of the following specifications:
6.2.1 Coating Type A—Aluminum-coated wire in accor-
dance with Specification A 809.
6.2.2 Coating Type Z—Zinc-coated wire in accordance with
Specification A 641/A 641M.
6.2.3 Coating Type ZA—Zinc-5 % aluminum-mischmetal
alloy (Zn-5Al-MM) coated wire in accordance with Specifica-tion A 856/A 856M.
TABLE 1 Standard Sizes and Constructions for Barbed Wire
Design Number Size, Steel Wire Gage Nominal Diameter of Coated
Wire, in. [mm] Number of Barb
Points Spacing of Barbs,
in. [mm] Diameter of Barbs, Steel
Wire GageA Shape of Barbs
Metallic Coating Type A 12-4-3-14RB 121⁄2 0.099 [2.51] 4 3 [76] 14 Round 12-4-5-14R 121⁄2 0.099 [2.51] 4 5 [127] 14 Round
Metallic Coating Type Z and Type ZA 12-2-4-12F 121⁄2 0.099 [2.51] 2 4 [102] 121⁄2C Flat 12-2-4-13F 121⁄2 0.099 [2.51] 2 4 [102] 13C Flat 12-2-4-14R 121⁄2 0.099 [2.51] 2 4 [102] 14 Round 12-2-5-12F 121⁄2 0.099 [2.51] 2 5 [127] 121⁄2C Flat 12-2-5-14R 121⁄2 0.099 [2.51] 2 5 [127] 14 Round 12-4-5-14H 121⁄2 0.099 [2.51] 4 5 [127] 14C Half-round 12-4-5-14R 121⁄2 0.099 [2.51] 4 5 [127] 14 Round 13-2-4-14R 131⁄2 0.086 [2.18] 2 4 [102] 14 Round 13-4-5-14R 131⁄2 0.086 [2.18] 4 5 [127] 14 Round 15-2-5-13F 151⁄2 0.067 [1.70] 2 5 [127] 133⁄4C Flat 15-2-5-14R 151⁄2 0.067 [1.70] 2 5 [127] 14 Round 15-4-5-16R 151⁄2 0.067 [1.70] 4 5 [127] 161⁄2 Round
AThe nominal diameter of the wire used in making the barbs shall be as follows:
121⁄2 gage 0.099 in. [2.51 mm] 13 gage 0.092 in. [2.32 mm] 133⁄4 gage 0.083 in. [2.11 mm] 14 gage 0.080 in. [2.03 mm] 161⁄2 gage 0.058 in. [1.47 mm]
BDesign Number 12–4–3–12R, Metallic Coated Type A, is High-Security Grade. All other design numbers are for standard grade.
CThe gage of the half-round and flat barbs is designated by the gage of the round wire from which the barbs are rolled.
TABLE 2 Minimum Weight of Coating on Type Z Barbed Wire
Size, Steel Wire Gage
Nominal Diameter of Type Z
Minimum Weight of Coating of Uncoated Wire Surface, oz/ft2[g/m2]
in. [mm] Class 1 Class 3
121⁄2 0.099 [2.51] 0.28 [85] 0.80 [245] 13 0.092 [2.32] 0.28 [85] 0.75 [230] 131⁄2 0.086 [2.18] 0.25 [75] 0.70 [215] 133⁄4 0.083 [2.11] A 0.70 [215] 14 0.080 [2.03] 0.25 [75] 0.70 [215] 151⁄2 0.067 [1.70] A 0.65 [200] 161⁄2 0.058 [1.47] A 0.60 [200]
AThese sizes only furnished with Class 3 Coating (Section 8).
TABLE 3 Minimum Weight of Coating on Type ZA Barbed Wire
Size Wire Gage
Nominal Diameter of Type ZA Wire
Minimum Weight of Coating of Uncoated Wire Surface, oz/ft2[g/m2] ClassA
in. [mm] 20 40 60 80 100 120
121⁄2 0.099 [2.51] XB X X X X X
13 0.092 [2.32] X X X X X X 131⁄2 0.086 [2.18] X X X X X X 133⁄4 0.083 [2.11] X X X X X X 14 0.080 [2.03] X X X X X X 151⁄2 0.067 [1.70] X X X X X X 161⁄2 0.058 [1.47 X X X X X X
ACoating Class 20 40 60 80 100 120 Coating Weight oz/ft2 0.20 0.40 0.60 0.80 1.00 1.20 (g/m)2 61 122 183 244 305 366
BX denotes availability.
A 121 – 99 (2004)
6.3 Coated Wire—The steel wire shall be coated before
fabrication.
6.3.1 Weight of Coating Requirements for Strand Wires—
The strand wires for Types Z and ZA barbed wire, as represented by the test specimens, shall conform to the requirements of Tables 2 and 3 respectively for the minimum coating weight for the type and class ordered. The strand wires for Type A barbed wire, as represented by the test specimens, shall have a minimum coating weight of 0.30 oz/ft2[90 g/m2] on the 121⁄2 –gage wire.
6.3.2 Weight of Coating Requirements for Barbs—The wire
for barbs for Types Z and ZA barbed wire, as represented by the test specimens, shall conform to the same coating class requirements as the strand wire. The steel wire for barbs for Type A barbed wire, as represented by the test specimens, shall have a minimum coating weight of 0.25 oz/ft2[75 g/m2] on the 14–gage wire.
7. General Requirements
7.1 The sizes and constructions for barbed wire furnished
under this specification shall be in accordance with the requirements of Table 1 for the Design Number specified in the order, within the tolerances stated in Section 8.
7.2 The barbs shall be sharp, well-formed, and tightly
wrapped. The barb length, measured from the center of the two strand wires, shall be3⁄8 in. [9.5 mm] minimum.
7.3 The strand wires shall be twisted with a uniform length
of lay. Type Z and Type ZA barbed wire shall have the twisting consistently in one direction (left or right) or alternating between the left and right directions. Type A barbed wire shall have the twisting consistently in either the left or right direction, with alternating of the twisting prohibited.
7.4 Splicing of individual wires by means of a wrap joint or
an electric butt weld is permitted. Not more than three splices or joints shall exist in any spool of barbed wire. Such splices or joints shall be made in a workmanlike manner.
7.5 The barbed wire, for the various types, shall be pack-
aged on spools in lengths as follows:
7.5.1 Type A—80 rods (1320 ft) [402 m] or 1000 ft [305 m].
7.6 Types Z and ZA—80 rods (1320 ft) [402 m] or 80 rods
plus additional increments of 10 rods (165 ft) [50 m].
7.7 Breaking Strength—The breaking strength of the
stranded barbed wire, for all types, shall be not less than 950 lbf [4230 N]. This breaking strength reflects that of both strand wires tested together as one unit.
8. Permissible Variations in Dimensions
8.1 Diameter—The permissible variation from the nominal
diameter of the wire, for both line wires and barbs, for all types, shall be60.005 in. [0.13 mm]
8.1.1 Due to the mechanics of manufacture when forming
the barbs, a certain amount of out-of-roundness is expected.
The size and condition precludes barbs from being subjected to diameter checks.
8.2 Barb Spacing—The nominal spacing of the barbs shall
be as noted in Table 1. The individual barb spacing shall be measured from the edge of one barb at the strand to the corresponding edge of the adjacent barb. Cumulative spacing is established by counting the total number of barbs in a 25-ft
[7.6-m] length of barbed wire. Barbs are subject to relocation during fabrication and handling, potentially leading to rejec-tions with rigid interpretation of the spacing requirement.
Therefore, barb spacing shall be considered acceptable under the following conditions:
8.2.1 The sample has 93.5 % of the individual barb spacings
conforming to the specified spacing63⁄4 in. [19 mm], and
8.2.2 A sample length of 25 ft [7.6 m] of barbed wire
contains:
8.2.2.1 A minimum of 86 barbs for 3-in. [76-mm] spacing,
8.2.2.2 A minimum of 69 barbs for 4-in. [102-mm] spacing, or
8.2.2.3 A minimum of 55 barbs for 5-in. [127-mm] spacing.
9. Sampling and Testing
9.1 Sampling—For the purpose of tests, select one spool at
random from every 50 spools or fraction thereof in a lot, or a total of seven samples, whichever is less. A lot shall consist of all spools of a single construction (Design Number) of barbed wire offered for delivery at the same time.
9.2 Test Specimens for Physical Tests—Cut a 4-ft [1.2-m]
length of barbed wire from the end of each spool for tests prescribed in Sections 6 and 7. Determine the breaking strength value by testing the twisted strand as composite. Test each strand wire individually for weight of coating.
9.3 Testing for Weight of Coating—Coating weight for
Types Z and ZA shall be determined in accordance with Test Method A 90/A 90M. Coating weight for Type A shall be determined in accordance with Test Method A 428/A 428M.
Perform testing either before or after fabrication for the strand wires and for Type A steel barbs. Perform testing prior to fabrication for Type Z and ZA barbs, and certify the test results.
9.4 Pretesting of Wire—Instead of testing wire for breaking
strength and weight of coating from the completed barbed wire in accordance with 9.2, the manufacturer, at his election, shall establish compliance with the requirements in Sections 6 and 7 by tests made on wire prior to fabrication. If the manufacturer makes this election, the purchaser still has the right to test wire from the completed barbed wire for compliance. It is recog-nized that during fabrication the barb is mechanically deformed and scraped, and some differences are likely in coating weight results on barbs tested before and after fabrication.
9.5 Inspection for General Workmanship—For the purpose
of inspection, a maximum of two spools from the lot, as described in 9.1, shall be subjected to observations for barb length and spacing, overall length, and workmanship.
9.5.1 Instead of inspecting for length by unrolling full
spools, the purchaser and manufacturer have the option of agreeing on a weight per spool related to wire size or measuring tools employed during manufacturing. The pur-chaser still reserves the right to confirm the length by actual measurement.
9.5.2 Inspection for barb spacing is normally performed on
the outer 25-ft [7.6-m] length of a spool, which permits repacking of the spool. Any other selection shall be as agreed upon between the manufacturer and the purchaser.
10. Retests
10.1 Lot Size for Retests—If one or more of the individual
wire specimens fail the coating weight, or if a strand specimen fails the breaking strength test, the lot shall be subject to retest.
For retest purposes, four additional spools of barbed wire for each 50 spools offered shall be sampled. The lot size then becomes 50 spools, except variation in lot size is permitted to accommodate pallet count when the barbed wire is palletized.
10.2 Retesting for Coating Weight—If more than two of the
individual strand wires of the retest specimens fail to meet the requirements of 6.3, or if any of the retest specimens has less than 75 % of the specified coating weight, the entire lot represented by the retest shall be rejected.
10.3 Retesting for Breaking Strength—If any of the retest
specimens fail to meet the minimum breaking strength value in 7.7, the entire lot represented by the specimens shall be rejected.
10.4 Reinspection for Barb Spacing, Barb Length, and
Overall Length—If either of the sample spools fails to meet the requirements for these dimensions, within the tolerances in Section 8, two additional spools shall be selected for inspec-tion. If either of these spools fails to meet the requirements, the lot shall be rejected.
11. Inspection
11.1 Unless otherwise specified in the purchase order or
contract, the manufacturer is responsible for the performance of all inspection and test requirements specified in this speci-fication. Except as otherwise specified in the purchase order or contract, the contractor shall use his own or any other suitable facilities for the performance of the inspection and test requirements unless disapproved by the purchaser at the time the order is placed. The purchaser shall have the right to perform any of the inspections and tests set forth in this specification when such inspections and tests are deemed necessary to ensure that the material conforms to the prescribed requirements.
12. Rejection and Rehearing
12.1 Material that fails to conform to the requirements of
this specification shall be rejected. Rejection shall be reported to the manufacturer or supplier promptly and in writing. In case of dissatisfaction with the results of the test, the manufacturer or supplier shall make claim for a rehearing.
12.2 Instead of rejecting the entire lot as provided in Section 10, the manufacturer has the option of testing specimens from every spool and rejecting only those spools failing the weight of coating or breaking strength requirements.
13. Certification
13.1 When specified in the purchase order or contract, a
manufacturer’s or supplier’s certification stating that the ma-terial was manufactured, sampled, tested, and inspected in…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .