This is an Addendum No. 1 to a contract document for the Beekman Elementary School Replacement Condensing Unit project (SO-1756) located at 2901 Wabash Road, Lansing, Michigan. The addendum, issued on February 18, 2021, addresses three key modifications to the original contract documents: the repair or replacement of outside air and return dampers (both measuring 20" x 84") to ensure proper functioning of the existing air handler; the specification that roof deck rails must be 14 inches tall and 4.5 inches wide; and clarification that Pate Pipe Portals are acceptable for use as pitch pockets on the project. The addendum was prepared by Bergmann PC and distributed to Theron Coe and Buddy Huyler. All requirements of the original drawings remain in force except as specifically noted in this addendum, and all incidental items necessary to provide the specified modifications must be included in the contractor's proposal.

The addendum addresses warranty and installation considerations regarding the Pate Pipe Portals, stipulating that they should be installed as required to maintain warranty. If the portals are not approved for warranty work by the roofing warranty company, that company must be brought into the approval process. The pourable sealer application will be the responsibility of the warranty roofing company. No pricing information, set-asides, funding sources, or contract award dates are specified in this addendum document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

560 5th St. NW Suite 305 TEL: 616.827.4270

Grand Rapids, MI 49504 www.bergmannpc.com

Addendum No. 1

Date: 02.18.2021

Project: Beekman Elementary School Replacement Condensing Unit SO-1756

Location: 2901 Wabash Rd #A, Lansing, MI 48910

Project No: 014936.00

Distribution: Theron Coe, Buddy Huyler.

This Addendum is issued to amend previously issued Contract Documents. Except as otherwise specifically mentioned, the general character of the work required by this Addendum shall be the same as originally specified. When an item is mentioned with additional drawing item given, reference shall be made to the original drawings.

The General Conditions and drawings of the original job shall govern for all work, unless otherwise noted.

All incidental items required to provide the following modifications shall be included in the Contractor’s proposal even though not specifically described. All requirements of the original Drawings shall remain in force except as noted by this ADDENDUM #1.

ITEM:

1. Do the outside air and return dampers need to be replaced?

2. What Height from the roof deck do the rails need to be?

3. Are Pate Pipe Portals ok for use as a pitch pocket and will Pourable Sealer be the responsibility of the Warranty Roofing Company and applied by them?

TO THE DRAWINGS

1. Sheet M101 (Not Re-issued)

1. Outside Air and Return Dampers need to be repaired or replaced to ensure proper functioning of existing Air Handler. Both are 20”x84”.

2. Roof deck Rails need to be 14” tall and 4.5” wide.

3. Pate Pipe Portals are acceptable to use as part of this project. Install as required to maintain warranty. If not approved for warranty work, please bring the warranty roofing company in.

ATTACHMENTS:

None.

END OF ADDENDUM NO. 1

SO-1756 Beekman Center Condensing Unit Addendum 1