This document is a site map for the Siesta Key Master Pump Station emergency storage tank cleaning project, prepared by Stantec for Sarasota County, Florida in March 2018. The site map details the layout of a water infrastructure facility, including a one-story building, pump house, administration building, sludge thickener, emergency storage tank, and various water main connections. The map includes a comprehensive fitting tag list with 23 different pipe and valve components, and shows the precise locations of power connections (single-phase 120V and three-phase 480V), potable water hydrants, and staging areas.
The site map provides a detailed technical schematic for the on-call cleaning of the emergency storage tank, indicating the complex infrastructure of the Siesta Key Master Pump Station. The drawing includes specific technical details such as PVC pipe sizes (6", 8", 12", 14", and 16"), gate valve locations, bend angles, reducers, and connection points. The diagram is oriented with a north arrow and includes precise positioning of various infrastructure elements, suggesting a comprehensive planning approach for potential maintenance or cleaning contractors bidding on the project.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| 232522TEG_PROJECT_DOCUMENTS.pdf | ||
| CONFINED_SPACE_ENTRY_PERMIT_EXAMPLE.pdf | ||
| CROM_DRAWINGS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ONE STORY BUILDING
(PUMP HOUSE)
ADMINISTRATION
BUILDING
SLUDGE
THICKENER
SLUDGE HOLDING
P
V C
F
M
P
W
P
CONNECT TO 16" PVC
WATER MAIN
EMERGENCY
STORAGE
TANK
P
POTABLE WATER
HYDRANT
MPS WETWELL
STAGING AREA
POWER (SINGLE PHASE)
SINGLE PHASE 120V
AND 3 PHASE 480V
POWER IN MCC
SINGLE PHASE 120V
AND 3 PHASE 480V
POWER IN MCC
N
MARCH 2018
FITTING TAG LIST
NUMBER DESC
16"x6" TEE (ROTATE)
2 6" GATE VALVE
3 12" GATE VALVE
12" TEE (ROTATE)
5 16"x14" REDUCER
6 12" 45° BEND
FIRE HYDRANT & VALVE
ASSEMBLY
8 16" 45° BEND
9 8" TEE
10 6" 45° BEND
11 12"x8" TEE
12 12" 90° BEND
13 14" GATE VALVE
14 6" QUICK CONNECT
12" WHEEL ACTUATED GATE
VALVE
16 AIR RELEASE VALVE
17 8" 45° BEND
FITTING TAG LIST
NUMBER DESC
18 8" 90° BEND
19 16"x12" REDUCER
20 12" TEE
21 14"x12" REDUCER
22 8" BLIND FLANGE
2" NIPPLE WITH S.S. BALL
VALVE
SIESTA KEY MASTER PUMP STATION ON-CALL CLEANING
OF EMERGENCY STORAGE TANK ATTACHMENT Awww.stantec.com Florida Certificate No. 27103
5172 Station Way Sarasota, FL. 34233
ATTACHMENT A - SITE MAP
AutoCAD SHX Text 2.6'
AutoCAD SHX Text 0.6'
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
(2) DUCTS
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
DUMPSTER PAD
AutoCAD SHX Text
12" PVC FM
AutoCAD SHX Text
12" PVC FM
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text 6.44
AutoCAD SHX Text 5.98
AutoCAD SHX Text 5.99
AutoCAD SHX Text 6.25
AutoCAD SHX Text 6.54
AutoCAD SHX Text 6.81
AutoCAD SHX Text 6.61
AutoCAD SHX Text 6.46
AutoCAD SHX Text 6.09
AutoCAD SHX Text 6.03
AutoCAD SHX Text 5.88
AutoCAD SHX Text 6.31
AutoCAD SHX Text 7.83
AutoCAD SHX Text 7.99
AutoCAD SHX Text 7.85
AutoCAD SHX Text 7.78
AutoCAD SHX Text
15" STORM PIPE
AutoCAD SHX Text DRAINAGE MANHOLE RIM ELEV= 7.58 E INV ELEV 12" TOP= 4.18 W INV ELEV 12" TOP= 4.18
AutoCAD SHX Text DRAINAGE MANHOLE RIM= 7.61 E INV 15" PIPE= 1.86 SW INV 15" PIPE= 1.96 NW INV 6" PIPE= 3.46 (UNABLE TO DETERMINE PIPE TYPES)
AutoCAD SHX Text
15" STORM
AutoCAD SHX Text
16" PVC WM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
PHH
AutoCAD SHX Text
AHH
AutoCAD SHX Text
PHH
AutoCAD SHX Text
AutoCAD SHX Text
PHH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text Saved: 3/8/2018 2:30:49 PM SPOPHAM | Plotted: 3/08/2018 3:00:50 PM SPOPHAM | \\US1233-F01\Workgroup\1773\Active\177310383\design\drawing\siesta_key_pump_station\active\civil\exhibit\figure_1.dwg|C-109 jdallman Cross-Out jdallman Cross-Out
| Sheets and Views |
| C-109 |
File details come from the government source that posted it. Updated .