SIGN_TYPES_Campus_Standard_Signage.pdf
PDF 480 KB Posted
- Attached to
- SIGN PACKAGE FOR THE UNIVERSITY OF WISCONSIN’S LIFE SCIENCES COMMUNICATION DEPARTMENT(UW-MAD)[20-0040]
- Solicitation number
- 20-0040
- Issued by
- Dane County, Wisconsin
About this file
This document is a comprehensive set of standard interior signage specifications and design standards developed by the University of Wisconsin-Madison's Facilities Planning and Management department. The specifications establish detailed requirements for signage installation across the UW campus, including identification signage, restroom signage, egress signage, wayfinding signage, and miscellaneous signage types. The document provides technical drawings and specifications for multiple sign types (ID-1 through ID-6, R-1 through R-3, E-1 through E-5, W-1 through W-6, and M-1 through M-4), each with precise dimensional requirements, mounting specifications, and placement guidelines. All signage must comply with ICC A117.1 accessibility standards, the Americans with Disabilities Act (ADA), International Building Code requirements, and UW guidelines. The specifications mandate that all text be tactile with Grade II Braille inclusions unless otherwise noted, use Helvetica font in uppercase only with non-glare material finishes, and maintain appropriate color contrast between backgrounds and text in accordance with ICC A117.1 standards.
The document specifies that standard signage colors are based on 2/90 signage color scheme, including black (#704), earth (#728), dark gray (#734), white (#708), and silver (#150) or brushed natural (#104). Room numbering must be coordinated with the UW Facilities Planning and Development Space Management Office (SMO). Installation details are provided for mounting on various surfaces including gypsum wallboard, concrete, and glass, with specifications for both mechanical fastening and VHB mounting tape adhesive applications. Minimum viewing heights are established at 80 inches above finished floor (AFF) for directional signage, with typical installation elevations provided for reference. The specifications include requirements for backer panel sizing for all glass-mounted signage, with minimum inset specifications of 1/4 inch from faceplates on all sides. These standards apply to the Life Sciences Communication Department signage package project (RFB 20-0040) at UW-Madison, with inquiries directed to Doreen Forslund at UW Purchasing Services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 20-0040 RFB.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(BRAILLE)
3/8
1/4
3/8
5/8
3/8
2"
6"
• STORAGE
• JANITOR/CUSTODIAL
• KITCHENETTE
• COPY ROOM
1/2"
ROOM NAME
(BRAILLE)
3/4
3/8
1/4
3/8
5/8
3/8
5/8
5/8
MARGIN
1/2"
4"
6"
ROOM NAME
• ADD'L PLAQUE FOR ROOM ID
• INFORMATIONAL TEXT WHICH
REQUIRES TACTILE LETTERING AND
BRAILLE (I.E. "EXIT ONLY", "NO
SMOKING")
(BRAILLE)
1/4
3 1 /2"
1/4
4"
6"
(WINDOW)
ROOM NAME
(BRAILLE)
2" 4"
6"
ROOM NAME
(BRAILLE)
• CONFERENCE ROOM
• CLASSROOM / LECTURE / AUDITORIUM
• DEPARTMENT OFFICE
• LABORATORY
• SPECIAL UTILITY ROOMS WHERE
APPLICABLE (I.E. FIRE COMMAND
CENTER")
• LACTATION / SPECIAL PURPOSE ROOM
• SUPPORT ROOMS (I.E. MAIL, COPY, ETC.)
ID-2
ID-1
6" (BRAILLE)
(BRAILLE)
2" 4"
6"
6"
• SINGLE OCCUPANT
• MULTIPLE OCCUPANTS
• OTHER NAMED ROOMS NOT
REQUIRED TO HAVE TACTILE
LETTERING & BRAILLE
(WINDOW)
ID-3
ID-1
(BRAILLE)
3/8
1/4
3/8
5/8
1/4 " 1
1/ 2"
1/4
2" 2"
6"
• PIN OR MAGNETIC MOUNT TO
WORKSTATION PANELS
(WINDOW)
SINGLE BACKER
INDIVIDUAL WINDOW AND
NUMBER, TAPE-MOUNT TO
BACKER
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-1
IDENTIFICATION SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE ID-1, ROOM NUMBER
6" = 1'-0"2 SIGN TYPE ID-2, ROOM NAME
6" = 1'-0"3 SIGN TYPE ID-3, WINDOW
6" = 1'-0"4 SIGN TYPE ID-4, NAMED ROOM
6" = 1'-0"5 SIGN TYPE ID-5, OFFICE
6" = 1'-0"6 SIGN TYPE ID-6, WORKSTATION
No. By: Date: Description:
WOMEN
6"
9"
3" 6"
M
IN
3/8
1/4
1 3 /8"
5/8
3/8
TEXT & BRAILLE CENTERED
HORIZONTALLY (TYP.)
WOMEN
(BRAILLE)
WOMEN
(BRAILLE)
WOMEN
(BRAILLE)
MEN
(BRAILLE)
6"
9"
3" 6"
3/8
1/4
3/8
5/8
3/8
5/8
3/8
TEXT & BRAILLE CENTERED
HORIZONTALLY (TYP.)
MEN
(BRAILLE)
MEN
(BRAILLE)
MEN
(BRAILLE)
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-2
RESTROOM SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE R-1, WOMEN'S RESTROOM OR LOCKER ROOM
6" = 1'-0"2 SIGN TYPE R-2, MEN'S RESTROOM OR LOCKER ROOM
*SEE SHEET "SIGN-3" FOR TYPICAL
RESTROOM SIGN CONSTRUCTION &
PICTOGRAM SIZE/PLACEMENT
SINGLE BACKER
INDIVIDUAL PICTO AND
TEXT PANELS,
TAPE-MOUNT TO BACKER
BA
CK
ER
IN
SE
T, A
LL
S
ID
ES
1/4
MI
N.
RESTROOM
(BRAILLE)
6"
3" 6"
9"
RESTROOM
(BRAILLE)
6"
3" 6"
9"
SHOWER
(BRAILLE)
6"
3" 6"
9"
RESTROOM
(BRAILLE)
6"
3" 6"
9"
RESTROOM
(BRAILLE)
6"
3" 6"
9"
3/8
1/4
3/8 " 5/8
3/8
" 5/8
3/8
1"
2 1 /2"
1/4
1 1 /4"
1"
MIN.
1/2"
MIN.
1/2"
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-3
RESTROOM SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
6" = 1'-0"2 SIGN TYPE R, TYPICAL SECTION
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE R-3, SINGLE USER RESTROOM / SHOWER
STAIR A
6"
2" 6"
8"
TEXT & BRAILLE CENTERED HORIZONTALLY3/8
1/4
3/8
5/8
3/8
• SILKSCREEN OR DIGITALLY PRINT TEXT
• NO BRAILLE REQUIRED
(REFERENCE MDF DOCUMENT FOR REQUIREMENTS)
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-4
EGRESS SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
6" = 1'-0"1 SIGN TYPE E-1, STAIR IDENTIFICATION, OUTSIDE STAIRWELL
6" = 1'-0"2 SIGN TYPE E-2, STAIR IDENTIFICATION, INSIDE STAIRWELL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
IN CASE OF FIRE
6"
4" 6"
3/8
3/8
1/4
3/8 "1
/2"3/8
1/2 "3/8
1/2
3/8
USE STAIR
DO NOT USE ELEVATOR
(BRAILLE)
TEXT & BRAILLE CENTERED
HORIZONTALLY
(BRAILLE)
SPACING OF MULTI-LINE
BRAILLE, IF REQ'D, SHALL
COMPLY WITH ICC A117.1
AREA OF REFUGE - INSTRUCTIONS
AREA OF REFUGE - OUTSIDE DOOR
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-5
EGRESS SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
6" = 1'-0"3 SIGN TYPE E-5, ELEVATOR INSTRUCTIONS
6" = 1'-0"2 SIGN TYPE E-4, AREA OF REFUGE, INSIDE STAIRWELL
6" = 1'-0"1 SIGN TYPE E-3, AREA OF REFUGE, OUTSIDE STAIRWELL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
ROOM 1234 - 5678
16"
AS
R
EQ
'D
2"
1/2"
1/2
1" 1/2
1/4
1 1 /2"
1/4
1 1/2" 1/2"
DEPARTMENT A
DEPARTMENT B
DEPARTMENT D
• INSERTS: MAGNETIC OR TAPE MOUNT
TO BACKER
• SILKSCREEN OR DIGITALLY PRINT TEXT
• TEXT SIZIES SHALL COMPLY WITH
TABLE 703.2.4-VISUAL CHARACTER
HEIGHT FROM ICC A117.1 - 09
ARROWS: 1.5" X 1.5" MAX.
ROOMS
1234-5678
4"
9"
1 1 /2"
MARGINS (TYP)
1/4" MIN
1/4
3 1 /2"
1/4
1 1/2" 1/4"
1/4"
• SILKSCREEN OR DIGITALLY
PRINT TEXT
• TEXT SIZIES SHALL COMPLY
WITH TABLE 703.2.4-VISUAL
CHARACTER HEIGHT FROM
ICC A117.1 - 09
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-6
WAYFINDING SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE W-1, LARGE DIRECTIONAL
6" = 1'-0"2 SIGN TYPE W-2, SMALL DIRECTIONAL
NOT TO EXCEED 12"
6" M
IN
. (PICTO OR TEXT/ARROWS)
MIN 80" AFF
MECHANICALLY
FASTENED TO WALL
• SILKSCREEN OR DIGITALLY PRINT TEXT
• TEXT SIZIES SHALL COMPLY WITH
TABLE 703.2.4-VISUAL CHARACTER
HEIGHT FROM ICC A117.1 - 09
6" M
IN
6"
(PICTO)
MIN 80" AFF
MECHANICALLY
FASTENED TO WALL
• SILKSCREEN OR DIGITALLY PRINT
TEXT/PICTOGRAMS
• TEXT SIZIES SHALL COMPLY WITH
TABLE 703.2.4-VISUAL CHARACTER
HEIGHT FROM ICC A117.1 - 09
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-7
WAYFINDING SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE W-3, LARGE FLAG
6" = 1'-0"2 SIGN TYPE W-4, SMALL FLAG
DIRECTORY
1/2
FO
OT
ER
1"
T
YP
. IN
SE
RT
2"
2"
AS
R
EQ
'D
3/1 6"
5/8
3/1
6" DEPARTMENT A ROOM 100
DEPARTMENT B ROOM 200
DEPARTMENT C ROOM 300
FLOOR 3
Department A Department B
FLOOR 4
Department C
16"
BUILDING NAME
1/2
1"
1/2
1/2" 1/2"
• INSERTS: MAGNETIC OR TAPE MOUNT TO BACKER
• SILKSCREEN OR DIGITALLY PRINT TEXT
• TEXT SIZIES SHALL COMPLY WITH TABLE 703.2.4-
VISUAL CHARACTER HEIGHT FROM ICC A117.1 - 09
• LOWERCASE TEXT ACCEPTABLE.
FOOTER: TAPE
MOUNT TO BACKER
HEADER: TAPE
MOUNT TO BACKER
INSERTS: TAPE MOUNT TO
BACKER OR MAGNETIC
HEADER: TAPE
MOUNT TO BACKER
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-8
WAYFINDING SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
6" = 1'-0"1 SIGN TYPE W-5, DIRECTORY LARGE
6" = 1'-0"2 SIGN TYPE W-5 & W-6 TYP. SECTION
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
DIRECTORY
AS
R
EQ
'D
1" T
YP
. IN
SE
RT
2" 2"
1/2
FO
OT
ER
DEPARTMENT A
DEPARTMENT B
DEPARTMENT C
FLOOR 3
Department A Department B
FLOOR 4
Department C
FLOOR 5
Department D Conference Room A
FLOOR 6
Department F
3/1 6"
5/8
3/1 6"
16"
1/2" 1/2"
BUILDING NAME
1/2
1" 1/2
1/2"
• INSERTS: MAGNETIC OR TAPE MOUNT TO BACKER
• SILKSCREEN OR DIGITALLY PRINT TEXT
• TEXT SIZIES SHALL COMPLY WITH TABLE 703.2.4-
VISUAL CHARACTER HEIGHT FROM ICC A117.1 - 09
• LOWERCASE TEXT ACCEPTABLE.
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-9
WAYFINDING SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
6" = 1'-0"1 SIGN TYPE W-6, DIRECTORY SMALL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
*MUST BE ABLE TO USE IN PORTRAIT
AND LANDSCAPE LAYOUT
12"
(WINDOW)
1/
2"
1/4" - 1/2" BORDER, TYPICAL
* MIN VIEWING SPACE: 10.5" X 16.5"
*MUST BE ABLE TO USE IN PORTRAIT
AND LANDSCAPE LAYOUT
9"
(WINDOW)
1/4" - 1/2" BORDER, TYPICAL
* MIN VIEWING SPACE: 8" X 10.5"
12"
MATCH WIDTH OF SIGN
3/4 " M
AX
(BRAILLE)
MESSAGE BAR - MAGNETIC OR
GRAVITY ROLLERS
MATCH WIDTH OF SIGN
2"
(BRAILLE)
OPEN IN USE
SLIDER
SILKSCREEN OR
DIGITALLY PRINT TEXT
TYP.
3/8" MARGIN
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-10
MISC. SIGNAGE
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 SIGN TYPE M-1, 11"X17" WINDOW
6" = 1'-0"2 SIGN TYPE M-2, 8.5" X 11" WINDOW
6" = 1'-0"3 SIGN TYPE M-3, MESSAGE BAR
6" = 1'-0"4 SIGN TYPE M-4, SLIDER
WALL
BACKER - INSET 1/4" MIN FROM
FACEPLATES, ALL SIDES
FACEPLATE
TACTILE TEXT
BRAILLE
BACKER PANELS
MECHANICALLY
FASTENED TO WALL FACEPLATES MOUNTED
WITH VHB MOUNTING
TAPE TO BACKERS
GLASS
BACKER - INSET 1/4" MIN FROM
FACEPLATES, ALL SIDES
FACEPLATE
TACTILE TEXT
BRAILLE
BACKER PANELS
FASTENED TO WALL WITH
VERY HIGH BOND (VHB)
MOUNTING TAPE OR
EQUIVALENT ADHESIVE
FACEPLATES ADHERED
TO BACKERS WITH VHB
MOUNTING TAPE
GLASS BACKER ON
OPPOISITE SIDE OF
GLASS, MATCH SIGNAGE
COLORS AND SIZE
3"
3"
TACTILE / BRAILLE - SINGLE DOOR TACTILE / BRAILLE - SINGLE DOOR W/ SIDELIGHT
BUILDING DIRECTORY
WAYFINDING - LARGE WAYFINDING - SMALL OVERHEAD FLAG
3'
- 4
" M
IN
5'
- 1
0" M
AX
MI
N.
3"
TACTILE / BRAILLE - DOUBLE DOOR
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
PRELIMINARY
NOT FOR CONSTRUCTION
Date Issued
REVISIONS:
Sheet Title:
Project Title:
Drawn By:
Facilities Planning and Management Physical Plant - Architects/ Engineers 30 N. Mills Street, Madison, WI 53715
University of Wisconsin-Madison
5/ 8/
:1
1:
P M
SIGN-11
INSTALLATION DETAILS
XX/XX/XXXX
UW CAMPUS STANDARD
INTERIOR SIGNAGE
FOSDAL
GENERAL NOTES
1 ALL SIGNAGE MUST COMPLY WITH THE
CURRENT REQUIREMENTS OF ICC A117.1,
AMERICANS WITH DISABILITIES ACT (ADA),
INTERNATIONAL BUILDING CODE, AND UW
GUIDELINES.
2 ALL TEXT MUST BE TACTILE AND INCLUDE
CORRESPONDING GRADE II BRAILLE UNLESS
NOTED OTHERWISE.
3 FONT: HELVETICA, UPPERCASE ONLY
UNLESS NOTED OTHERWISE. CHARACTERS
SHALL NOT BE ITALIC, OBLIQUE, SCRIPT,
HIGHLY DECPRATIVE, OR OF OTHER UNUSAL
FORMS. THE USE OF SARIF FONTS IS
PROHIBITED.
4 COLOR CONTRAST BETWEEN BACKGROUND
AND TEXT/PICTOGRAMS SHALL MEET
REQUIREMENTS OF ICC A117.1. STANDARD
COLORS ARE BASED ON 2/90 SIGNAGE
COLORS:
- BLACK #704
- EARTH #728
- DARK GRAY #734
- WHITE #708
- SILVER #150 OR BRUSHED NATURAL #104
5 ROOM NUMBERING MUST BE COORDINATED
WITH UW FP&D SPACE MANAGEMENT
OFFICE (SMO)
6 MATERIAL FINISHES SHALL BE NON-GLARE.
7 INCLUDE APPROPRIATELY SIZED BACKER
PANELS FOR ALL GLASS-MOUNTED SIGNAGE
8 SEE SHEET "SIGN-11" FOR TYPICAL
INSTALLATION DETAILS.
6" = 1'-0"1 TYP. MOUNTING - GWB & CONCRETE
6" = 1'-0"2 TYP. MOUNTING - GLASS
1/2" = 1'-0"3 TYPICAL INSTALLATION ELEVATIONS
3 4
1 2
1 2
1 4
3 4
3 8
3 8
3 8
3 8
1" 1"
1'-1
STAIR S1
LEVEL
LEVEL G TO 5
ROOF ACCESS
DOWN TO LEVEL G
FOR EXIT
DISCHARGE
P1
P2
STW
Sign Type STW (Stairwell)
6" = 1'-0"
Applies to all rooms labeled STAIR, to be applied inside of stairwell at each level.
(BRAILLE)
Letters to meet Visual Character and Raised Character
Criteria of ICC A117-1
Letters in high rise buildings are required to be self-luminous or photoluminescent in accordance with IBC 1025.A
| Sheets |
| SIGN-1 - IDENTIFICATION SIGNAGE |
| SIGN-2 - RESTROOM SIGNAGE |
| SIGN-3 - RESTROOM SIGNAGE |
| SIGN-4 - EGRESS SIGNAGE |
| SIGN-5 - EGRESS SIGNAGE |
| SIGN-6 - WAYFINDING SIGNAGE |
| SIGN-7 - WAYFINDING SIGNAGE |
| SIGN-8 - WAYFINDING SIGNAGE |
| SIGN-9 - WAYFINDING SIGNAGE |
| SIGN-10 - MISC. SIGNAGE |
| SIGN-11 - INSTALLATION DETAILS |
| Sign Types STW (Stairwell).pdf |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .