SHS Welding Lab_Bid_Drawings_2026-09-01.pdf
PDF 13 MB Posted
- Solicitation number
- IFB-127578
- Issued by
- James City County, Virginia
About this file
Smithfield High School Welding Lab Renovations - Bid Drawings Summary
This is a comprehensive set of bid drawings prepared by RRMM Architects, PC for Isle of Wight County Schools for the interior renovation of a 3,574 square-foot space within Smithfield High School's existing Career & Technology Building located at 1417 Turner Drive, Smithfield, Virginia. The project scope includes construction of a new welding lab (2,062 SF), welding classroom (582 SF), storage space (384 SF), men's and women's locker rooms (106 SF each), and a workroom (215 SF). The facility is designed for a maximum occupancy of 80 persons and will serve as a one-story educational vocational space. The drawings represent the 100% submittal phase dated September 1, 2026, and include architectural, structural, mechanical, plumbing, and electrical design documents. The project is classified as Occupancy Group E (Educational) under the 2021 Virginia Construction Code and Construction Type IIB Unprotected (Sprinklered).
The bid drawings include detailed specifications for structural work, including foundation plans, roof framing plans, and typical construction details. Significant design elements include new concrete slab-on-grade with fiber reinforcement, existing steel structure integration, new masonry wall construction toothed into existing CMU, and new overhead coiling door installations. The project involves extensive demolition of existing interior elements, including removal of walls, floor coverings, existing suspended ceiling systems, and selective masonry removal. Special inspections are required for concrete, structural masonry, structural steel fabrication and erection, and post-installed anchors per International Building Code Section 1704. Building code compliance is based on the 2021 Virginia Uniform Statewide Building Code with wind speeds of 127 MPH basic design wind speed and seismic design category A. The project documentation references Invitation for Bid (IFB) #27-02 and includes coordination requirements across all trades for proper installation of mechanical, electrical, plumbing, and structural systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SHS Welding Lab_Bid_Project Manual_2026-09-01.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISLE OF WIGHT COUNTY SCHOOLS
RRMM ARCHITECTS, PC
ARCHITECTURE / PLANNING / INTERIORS
1317 Executive Boulevard, Suite 200
Chesapeake, VA 23320
(757) 622-2828
310 1st Street SW, Suite 100
Roanoke, VA 24011
(540) 344-1212
VOLUME 1 OF 1
SMITHFIELD HIGH SCHOOL VICINITY MAP CONSULTANTS OWNER
SPEIGHT, MARSHALL & FRANCIS, P.C.
STRUCTURAL ENGINEERING
1228 Perimeter Pkwy Way, Suite 201 Virginia Beach, VA 23454 P: (757) 427-1020
THOMPSON CONSULTING ENGINEERS
MEP ENGINEERING
22 Enterprise Pkwy, Suite 120 Hampton, VA 23666 P: (757) 599-4415 F: (757) 599-4113
ISLE OF WIGHT COUNTY SCHOOLS
9307 Old Stage Hwy Smithfield, VA 23430 Phone: (757) 357-4393
SITE
115 South 15th Street, Suite 502
Richmond, VA 23219
(804) 277-8987
3700 Koppers Street, Suite 300
Baltimore, MD 21227
(410) 234-8444
2900 South Quincy Street, Suite 710
Arlington, VA 22206
(703) 998-0101
SMITHFIELD HIGH SCHOOL WELDING LAB RENOVATIONS
SMITHFIELD HIGH SCHOOL LOCATION MAP
SITE
Lic. No. 10748
JEFFREY A HARRIS
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
2026-09-01
/3
/2
:2
:3
P
M A u to d e s k D o c s /2
-0 I
O W
C S
S m it h fi e ld
H S
W e ld in g /2
-0 v
S m it h fi e ld
H S
W e ld in g B u ild in g
A R
C H
.r v t
G-001
-0
J A
H
M M
H
J A
H
IF
B
-0
T
IT
L E
S H
E E
T
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
SHEET INDEX
Sheet Number Sheet Title
PROJECT TITLE SHEET
G-001 TITLE SHEET
LIFE SAFETY
LS101 LIFE SAFETY FLOOR PLAN
ARCHITECTURAL DEMOLITION
AD101 DEMOLITION FLOOR PLAN
AD102 REFLECTED CEILING PLAN - DEMOLITION
ARCHITECTURAL
A-001 GENERAL INFORMATION
A-002 PARTITION TYPES & TERMINATIONS AND ACCESSIBILITY GUIDELINES
A-100 OVERALL FLOOR PLAN
A-101 FLOOR PLAN - NEW WORK
A-102 REFLECTED CEILING PLAN -NEW WORK
A-301 MISCELLANEOUS DETAILS
A-601 FINISH SCHEDULE AND LEGEND
A-602 DOOR SCHEDULE & DOOR DETAILS
PLUMBING
P-001 LEGEND, NOTES AND ABBREVIATIONS
PD101 FLOOR PLAN - DEMOLITION - DRAIN, WASTE AND VENT
PD201 FLOOR PLAN - DEMOLITION - DOMESTIC WATER
P-101 FLOOR PLAN - NEW WORK - DRAIN, WASTE AND VENT
P-201 FLOOR PLAN - NEW WORK - DOMESTIC WATER, COMPRESSED AIR, AND
WELDING GASES
MECHANICAL
M-001 GENERAL NOTES, ABBREVIATIONS, LEGEND, AND SCHEDULES
MD101 FLOOR PLANS - DEMOLITION - MECHANICAL
M-101 FLOOR PLANS - NEW WORK - MECHANICAL
M-201 MECHANICAL DETAILS AND CONTROLS
ELECTRICAL
E-001 LEGEND, ABBREVIATIONS, GENERAL NOTES AND SCHEDULE.
ED101 FLOOR PLAN - DEMOLITION - LIGHTING AND AUXILIARY SYSTEMS
ED201 FLOOR PLAN - DEMOLITION - POWER
E-101 FLOOR PLAN - NEW WORK - LIGHTING AND AUXILIARY SYSTEMS
E-201 FLOOR PLAN - NEW WORK - POWER
E-301 ELECTRICAL OVERALL FLOOR PLAN
E-401 PANELBOARD SCHEDULES AND ONE LINE DIAGRAM
IFB#:27-02
GENERAL NOTES:
1. THE STRUCTURAL DRAWINGS MUST BE USED IN CONJUNCTION WITH THE
ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL
DRAWINGS AND THE SPECIFICATIONS. THE CONTRACTOR MUST VERIFY
THE REQUIREMENTS OF OTHER TRADES FOR ITEMS TO BE PLACED OR
SET IN THE STRUCTURAL WORK.
2. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE
PROVISIONS OF THE INTERNATIONAL BUILDING CODE, 2021 EDITION, AS
ADOPTED BY THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, 2021
EDITION INCLUDING THE 2022 ASCE-7.
3. THE WORK UNDER THE FOLLOWING SPECIFICATION SECTIONS IS SUBJECT
TO SPECIAL INSPECTIONS AND TESTS AS DESCRIBED IN SECTION 1704 OF
THE INTERNATIONAL BUILDING CODE, 2021 EDITION:
A. 032000 – CONCRETE REINFORCING
B. 033000 – CAST-IN-PLACE CONCRETE
C. 042000 – UNIT MASONRY
D. 051200 – STRUCTURAL STEEL FRAMING
4. THE CONTRACTOR MUST BE RESPONSIBLE FOR TEMPORARY SHORING
AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN
PROPER ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL
BRACING ARE IN PLACE.
5. BEFORE PROCEEDING WITH WORK WITHIN OR NEAR THE EXISTING
STRUCTURE, THE CONTRACTOR MUST BECOME FAMILIAR WITH THE
EXISTING STRUCTURAL CONDITIONS. THE SHORING AND BRACING
SHOWN IS A PARTIAL AND SCHEMATIC REPRESENTATION OF THAT
REQUIRED. THE CONTRACTOR MUST BE RESPONSIBLE FOR THE DESIGN
AND ERECTION OF ALL SAFEGUARDS NECESSARY TO PROTECT THE
EXISTING STRUCTURE FROM DAMAGE.
6. THE CONTRACTOR MUST FIELD VERIFY THE DIMENSIONS, ELEVATIONS
AND OTHER REQUIREMENTS NECESSARY FOR THE PROPER
CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE
STRUCTURE TO THE EXISTING. THE CONTRACTOR MUST MAKE ALL
MEASUREMENTS NECESSARY FOR FABRICATION AND ERECTION OF
STRUCTURAL MEMBERS.
7. THE PROJECT SPECIFICATIONS ARE NOT SUPERSEDED BY THE
STRUCTURAL NOTES BUT ARE INTENDED TO BE COMPLEMENTARY TO
THEM. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS
IN EACH SECTION.
8. SPECIFIC NOTES AND DETAILS ON THE DRAWINGS MUST TAKE
PRECEDENCE OVER STRUCTURAL NOTES AND TYPICAL DETAILS.
9. CONSULTANTS’ DRAWINGS, INCLUDING STRUCTURAL DRAWINGS, ARE
CONSIDERED SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. ANY
OMISSIONS OR CONFLICTS, INCLUDING DIMENSIONS, BETWEEN VARIOUS
ELEMENTS OF THE CONSULTANTS’ DRAWINGS AND/OR SPECIFICATIONS
MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK.
10. THE DOCUMENTS DEFINING THE STRUCTURE ARE INSTRUMENTS OF
SERVICE PREPARED BY SPEIGHT, MARSHALL AND FRANCIS, P.L.L.C. FOR
ONE USE ONLY. THE STRUCTURAL DOCUMENTS MUST NOT BE
REPRODUCED, OR COPIED IN WHOLE OR IN PART BY THE CONTRACTOR
OR SUBCONTRACTORS FOR PREPARATION OF SHOP DRAWINGS OR
OTHER SUBMITTALS WITHOUT WRITTEN PERMISSION FROM THE
ARCHITECT.
11. LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS:
A. DEAD LOADS:
1. ROOF 20 PSF
B. LIVE LOADS:
1. SLAB-ON-GRADE 100 PSF
2. ROOF 20 PSF
C. SNOW DESIGN DATA:
1. GROUND SNOW LOAD 46 PSF
EXPOSURE FACTOR 1.0
2. THERMAL FACTOR 1.13
3. FLAT ROOF SNOW LOAD 36.2 PSF
4. MINIMUM SNOW LOAD 35 PSF
D. WIND DESIGN DATA:
1. BASIC DESIGN WIND SPEED 127 MPH
2. ALLOWABLE STRESS DESIGN WIND SPEED 98 MPH
3. RISK CATEGORY III
4. WIND EXPOSURE C
5. INTERNAL PRESSURE COEFFICIENT ±0.18
6. WIDTH OF COMPONENTS AND CLADDING
COEFFICIENT PRESSURE ZONE a = 9 FT
7. COMPONENTS AND CLADDING DESIGN PRESSURES
A. ZONE 1 WITH 10 SF TRIBUTARY AREA 66 PSF
B. ZONE 4 WITH 10 SF TRIBUTARY AREA 36 PSF
E. SEISMIC DESIGN DATA:
1. RISK CATEGORY III
2. SEISMIC IMPORTANCE FACTOR 1.25
3. SS 0.120g
4. S1 0.042g
5. SITE CLASS D
6. SDS 0.110g
7. SD1 0.060g
8. SEISMIC DESIGN CATEGORY A
12. NO MECHANICAL UNITS HAVE BEEN CONSIDERED IN THE STRUCTURAL
DESIGN. SUBMIT LOCATION, DIMENSIONS AND OPERATING WEIGHTS OF
ANY UNITS WEIGHING MORE THAN 100 POUNDS TO THE STRUCTURAL
ENGINEER FOR REVIEW, PRIOR TO PLACEMENT.
CONCRETE MASONRY NOTES:
1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE
MASONRY SOCIETY (TMS) “BUILDING CODE FOR MASONRY STRUCTURES”
TMS 402-16.
2. CONCRETE MASONRY CONSTRUCTION MUST CONFORM TO THE MASONRY
SOCIETY (TMS) “SPECIFICATION FOR MASONRY STRUCTURES” TMS 602-16.
3. CONCRETE MASONRY UNITS MUST CONFORM TO ASTM C90 AND BE MADE
WITH LIGHTWEIGHT AGGREGATE. THE COMPRESSIVE STRENGTH OF
MASONRY, F’m, EXPRESSED AS FORCE PER UNIT OF NET CROSS
SECTIONAL AREA, MUST BE 2,000 PSI AT 28 DAYS.
4. REINFORCING STEEL MUST COMPLY WITH ASTM A615, GRADE 60. SHOP
FABRICATE REINFORCING BARS SHOWN TO BE BENT OR HOOKED.
5. GROUT MUST COMPLY WITH ASTM C476 OR IBC SECTION 2103.3, AND
MUST BE PROPORTIONED TO OBTAIN A 28 DAY COMPRESSIVE STRENGTH
OF 2,500 PSI.
6. MORTAR MUST COMPLY WITH ASTM C270, TYPE S OR M. AGGREGATE FOR
MORTAR MUST COMPLY WITH ASTM C144. AGGREGATE FAILING TO
COMPLY WITH ASTM C144 GRADATION REQUIREMENTS MAY BE USED
PROVIDED THE MORTAR CAN BE PREPARED TO COMPLY WITH THE
AGGREGATE RATIO, WATER RETENTION AND COMPRESSIVE STRENGTH
REQUIREMENTS OF THE PROPERTY SPECIFICATIONS OF ASTM C270. USE
TYPE M BELOW GRADE AND TYPE S ABOVE GRADE (UNLESS CELLS ARE
GROUTED SOLID).
7. VERTICAL REINFORCING BARS MUST BE THE GIVEN SIZE AND SPACING
SHOWN. LAP REINFORCING AT ALL SPLICES AS FOLLOWS:
A. #3 – 19” B. #4 – 25” C. #5 – 31” D. #6 – 52” E. #7 – 67” F. #8 – 93” G. #9 – 119”
H. #10 OR LARGER – ‘MECHANICALLY SPLICED’
8. REINFORCE NEW CMU WALLS WITH #4 AT 48" ON-CENTER.
STRUCTURAL STEEL NOTES:
1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FOURTEENTH EDITION OF THE AMERICAN INSTITUTE OF STEEL
CONSTRUCTION (AISC 360-16) “STEEL CONSTRUCTION MANUAL” –
ALLOWABLE STRESS DESIGN.
2. STRUCTURAL STEEL MUST COMPLY WITH THE FOLLOWING
SPECIFICATIONS:
A. STRUCTURAL STEEL W- AND WT-SHAPES – ASTM A992, Fy=50 KSI B. RECTANGULAR AND SQUARE HSS – ASTM A500, GRADE C, Fy=50 KSI
C. ANCHOR RODS – ASTM F1554, GRADE 36 (WELDABLE)
D. HEADED STUDS - ASTM A 108, GRADES 1015 THROUGH 1020, TYPE B,
Fu=65 KSI
E. ALL OTHER STRUCTURAL STEEL SHAPES, PLATES AND BARS – ASTM
A36, Fy=36 KSI (UNLESS OTHERWISE NOTED)
3. WELDING MUST BE IN ACCORDANCE WITH AWS D1.1, “STRUCTURAL
WELDING CODE – STEEL”. WELD ELECTRODES MUST BE E70XX.
CONTINUOUS 3/16” FILLET WELDS ARE REQUIRED UNLESS OTHERWISE
NOTED.
4. SEE THE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING AND
ELECTRICAL DRAWINGS FOR ADDITIONAL STEEL (IF ANY) NOT SHOWN ON
THE STRUCTURAL DRAWINGS.
5. UNLESS OTHERWISE NOTED, THE TOP OF ALL STEEL COLUMNS MUST
HAVE A STEEL CAP PLATE. UNLESS OTHERWISE DETAILED OR NOTED,
MINIMUM CAP PLATE DIMENSIONS MUST MATCH COLUMN WIDTH AND
DEPTH AND MINIMUM THICKNESS OF CAP PLATE MUST EQUAL COLUMN
WEB THICKNESS (1/2" MINIMUM).
6. UNLESS OTHERWISE NOTED, ATTACH BLOCKING AND NAILERS TO STEEL
FRAMING USING 3/16” DIAMETER POWDER ACTUATED FASTENERS AT 24”
ON-CENTER OR 1/2” DIAMETER BOLTS AT 48” ON-CENTER. STAGGER
FASTENERS TO ALTERNATE SIDES OF BEAM WEB.
7. STRUCTURAL STEEL NOTED TO BE GALVANIZED MUST CONFORM TO ASTM
A123 OR ASTM A153. GALVANIZE STRUCTURAL STEEL AFTER FABRICATION
WHERE PRACTICAL. REPAIR DAMAGED GALVANIZED COATING USING
ASTM A780 ZINC-RICH PAINT.
POST-INSTALLED ANCHOR NOTES:
1. POST-INSTALLED ANCHORS MUST CONSIST OF THE FOLLOWING ANCHOR
TYPES (OR APPROVED EQUIVALENT) UNLESS NOTED OTHERWISE:
A. ANCHORAGE TO CRACKED AND/OR UNCRACKED CONCRETE:
1. ADHESIVE ANCHORS:
A. HILTI HIT-HY 200 V3, SAFE SET SYSTEM WITH HILTI HIT-Z
ROD OR HILTI HOLLOW DRILL BIT SYSTEM WITH HAS-E
THREADED ROD AT CONTRACTOR’S OPTION
2. MECHANICAL ANCHORS:
A. HILTI KWIK BOLT-TZ2 EXPANSION ANCHOR (SAFE SET
SYSTEM WITH HOLLOW DRILL BIT AND VACUUM AND SI-
AT-A22 TOOL WITH ADAPTIVE TORQUE FOR APPLICABLE
SIZES PER ICC ESR-4266)
B. HILTI KWIK BOLT 1 EXPANSION ANCHOR(SAFE SET
SYSTEM WITH HOLLOW DRILL BIT AND VACUUM AND SI-
AT-A22 TOOL WITH ADAPTIVE TORQUE FOR APPLICABLE
SIZES PER ICC ER-678)
B. REBAR DOWELING INTO CRACKED AND/OR UNCRACKED CONCRETE:
1. ADHESIVE ANCHORS:
A. HILTI HIT-HY 200 V3 SAFE SET SYSTEM WITH HILTI
HOLLOW DRILL BIT SYSTEM WITH CONTINUOUSLY
DEFORMED REBAR
C. ANCHORAGE TO SOLID GROUTED MASONRY:
1. ADHESIVE ANCHORS:
A. HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING
SYSTEM WITH HILTI HAS-E THREADED ROD
2. MECHANICAL ANCHORS:
A. HILTI KWIK BOLT-TZ2 EXPANSION ANCHORS
B. HILTI KWIK HUS-EZ SCREW ANCHOR
D. ANCHORAGE TO HOLLOW OR MULTI-WYTHE BRICK MASONRY:
1. ADHESIVE ANCHORS:
A. HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING
SYSTEM WITH HILTI HAS-E THREADED ROD
B. THE APPROPRIATE SIZE SCREEN TUBE MUST BE USED
PER ADHESIVE MANUFACTURER’S RECOMMENDATION
2. MECHANICAL ANCHORS:
A. HILTI KWIK-CON + SCREW ANCHORS
2. REQUESTS FOR ANCHOR SUBSTITUTIONS MUST BE APPROVED IN WRITING
BY THE STRUCTURAL ENGINEER OF RECORD. CONTRACTOR MUST SUBMIT
TECHNICAL DATA DEMONSTRATING THE PROPOSED ANCHOR
SUBSTITUTIONS MEET OR EXCEED THE STRENGTH AND PERFORMANCE
VALUES OF THE SPECIFIED ANCHORS.
3. INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS INCLUDED IN
THE ANCHOR PACKAGING.
4. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE HILTI
PROFI SYSTEM (OR EQUIVALENT). FOR PROJECTS MEETING IBC 2012 OR
LATER, ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION IS
REQUIRED FOR ALL INSTALLERS OF ADHESIVE ANCHORS IN HORIZONTAL
OR UPWARDLY INCLINED ORIENTATION. THE HILTI ADHESIVE ANCHOR
INSTALLER CERTIFICATION PROGRAM (HAAICP) IS AN APPROVED
EQUIVALENT.
5. THE CONTRACTOR MUST ARRANGE A REPRESENTATIVE OF THE ANCHOR
MANUFACTURER TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL
ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF
RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE
CONTRACTOR’S PERSONNEL INSTALLING ANCHORS ARE TRAINED PRIOR
TO THE COMMENCEMENT OF INSTALLING ANCHORS.
6. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT
ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL
ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES
INDICATED.
7. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY
CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS OTHERWISE
NOTED, EXISTING REINFORCING BARS CANNOT BE CUT. THE CONTRACTOR
MUST REVIEW THE EXISTING STRUCTURAL DRAWINGS AND MUST LOCATE
THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE
CONCRETE ANCHORS BY HILTI FERROSCAN, GPR, X-RAY, CHIPPING OR
OTHER MEANS.
SPECIAL INSPECTIONS:
1. SPECIAL INSPECTIONS MUST BE COMPLETED FOR THE FOLLOWING
ELEMENTS ACCORDING TO IBC SECTION 1704.
2. CONCRETE AND ELEMENTS EMBEDDED IN CONCRETE MUST BE SPECIAL
INSPECTED PRIOR TO AND DURING PLACEMENT OF CONCRETE. SPECIAL
INSPECTIONS MUST INCLUDE THE FOLLOWING:
A. PERIODIC INSPECTION:
1. REINFORCING STEEL SIZE AND PLACEMENT
2. VERIFY USE OF APPROVED MIX DESIGN
3. AFTER PLACEMENT TO ENSURE ADEQUATE CURING AND
WEATHER PROTECTION PROCEDURES
4. SURFACE PREPARATION AND DETAILS AT COLD JOINTS,
INCLUDING PLACEMENT OF KEYWAYS
B. CONTINUOUS INSPECTION:
1. BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING
PLACEMENT OF CONCRETE
2. DURING PLACEMENT OF CONCRETE
3. STRUCTURAL MASONRY MUST BE SPECIAL INSPECTED ACCORDING TO
THE FOLLOWING:
A. PERIODIC INSPECTION:
1. PROPORTIONS OF SITE-PREPARED MORTAR
2. CONSTRUCTION OF MORTAR JOINTS
3. SPECIFIED SIZE, LOCATION, GRADE AND TYPE OF
REINFORCEMENT
4. SIZE AND LOCATION OF STRUCTURAL ELEMENTS
5. TYPE, SIZE AND LOCATION OF ANCHORS INCLUDING DETAILS
OF ANCHORAGE OF MASONRY TO PRIMARY STRUCTURAL
SYSTEM
6. CLEANLINESS OF GROUT SPACE
7. PROTECTION OF MASONRY DURING HOT AND COLD WEATHER
PLACEMENT
B. CONTINUOUS INSPECTION:
1. PREPARATION OF ANY GROUT SPECIMENS, MORTAR
SPECIMENS AND/OR PRISMS
2. GROUT PLACEMENT MUST BE VERIFIED TO ENSURE
COMPLIANCE WITH CODE AND CONSTRUCTION DOCUMENT
PROVISIONS
4. STRUCTURAL STEEL FABRICATION AND ERECTION MUST BE SPECIAL
INSPECTED AS FOLLOWS:
A. PERIODIC INSPECTION:
1. SINGLE-PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16”
2. STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH
CONSTRUCTION DOCUMENTS INCLUDING MEMBER LOCATIONS,
CONNECTION DETAILS AND ANY OTHER BRACING AND
STIFFENING DETAILS
5. POST-INSTALLED ANCHORS INCLUDING BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS AND LOW VELOCITY FASTENERS MUST BE
SPECIAL INSPECTED ACCORDING TO THE RELEVANT ANCHOR CODE
EVALUATION REPORTS.
A. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING THE
INSTALLATION OF POST-INSTALLED ANCHORS.SPECIAL INSPECTOR
MUST VERIFY THE FOLLOWING:
1. ANCHOR SIZE AND STEEL GRADE
2. HOLE DIAMETER, LOCATION AND TYPE OF DRILL BIT
3. COMPLIANCE WITH MANUFACTURER’S INSTRUCTIONS
INCLUDING HOLE AND ANCHOR CLEANLINESS AND ADHESIVE
APPLICATION
4. ANCHOR EMBEDMENT DEPTH
6. SEE THE IBC AND OTHER CONSULTANTS’ DRAWINGS FOR NON
STRUCTURAL ITEMS REQUIRED TO BE SPECIAL INSPECTED.
CAST-IN-PLACE CONCRETE NOTES:
1. CAST-IN-PLACE CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH
THE AMERICAN CONCRETE INSTITUTE (ACI) “BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-19) AND
COMMENTARY (ACI 318R-19)”.
2. CONCRETE MUST BE NORMAL WEIGHT AND OBTAIN A 28 DAY
COMPRESSIVE STRENGTH OF 3,500 PSI.
3. REINFORCING MATERIALS MUST BE AS FOLLOWS:
A. REINFORCING BARS – ASTM A615, GRADE 60, DEFORMED
B. FIBER REINFORCING:
1. FIBRILLATED SYNTHETIC MACROFIBERS - ASTM C116, TYPE III
4. ALL REINFORCING STEEL AND EMBEDDED ITEMS MUST BE ACCURATELY
PLACED IN THE POSITIONS SHOWN AND ADEQUATELY TIED AND
SUPPORTED BEFORE CONCRETE IS PLACED TO PREVENT DISPLACEMENT
BEYOND PERMITTED TOLERANCES.
5. CONCRETE COVER MUST COMPLY WITH THE 'CONCRETE COVER
SCHEDULE' ON THIS SHEET. MINIMUM CONCRETE COVER FOR
REINFORCING STEEL AS INDICATED ON THE DRAWINGS MUST GOVERN
WHEN IN CONFLICT WITH ACI 318-19.
6. UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS:
A. LAP SPLICE LENGTHS MUST COMPLY WITH ‘CAST-IN-PLACE
CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE’ ON THIS
SHEET
B. USE TENSION BAR LAP SPLICE LENGTHS
STRUCTURAL TESTING NOTES:
1. THE FOLLOWING MATERIALS MUST BE TESTED ACCORDING TO IBC
SECTION 1705. ANY ITEMS FOUND TO BE DEFICIENT MUST BE CORRECTED
AND RE-TESTED AT NO ADDITIONAL COST TO THE OWNER.
2. CONCRETE STRENGTH VERIFICATION AND TESTING: ALL CONCRETE MUST
BE TESTED TO VERIFY STRENGTH, SLUMP, UNIT WEIGHT, AIR CONTENT
AND TEMPERATURE. SEE THE SPECIFICATIONS FOR TESTING CRITERIA,
FREQUENCY AND ACCEPTABILITY CRITERIA.
3. STRUCTURAL STEEL: WELDED CONNECTIONS MUST BE TESTED FOR
COMPLIANCE WITH THE SPECIFICATIONS, AWS D.1.1 AND THE CONTRACT
DOCUMENTS. MINIMUM TESTING MUST INCLUDE THE FOLLOWING:
A. ALL DEFICIENT WELDS MUST BE CORRECTED AND RE-TESTED AT NO
ADDITIONAL COST TO THE OWNER
4. POST-INSTALLED ANCHORS INCLUDING, BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS AND LOW VELOCITY FASTENERS, MUST
BE TESTED ACCORDING TO THE RELEVANT ANCHOR CODE EVALUATION
REPORTS.
5. SEE THE IBC AND OTHER CONSULTANTS’ DRAWINGS FOR NON
STRUCTURAL ITEMS REQUIRED TO BE TESTED.
WITH
PLUS/MINUS
DIAMETER
CENTERLINE
ON-CENTER
ANCHOR BOLT
ARCHITECT or ARCHITECTURAL
BOTTOM
BAR DIAMETER
BUILDING
BEAM
BRACING
BRIDGING
CENTER OF GRAVITY
CAST IN PLACE
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
COORDINATE
DETAIL
DIAMETER
DRAWING
EACH FACE
EACH WAY
EACH
ELEVATION
ELECTRICAL
ELEVATOR or ELEVATION
EXISTING
EXPANSION
FACE OF
FIRST RISER
FINISH or FINISHED
FLOOR
FOOTING
HOLLOW CORE
HOOK
HORIZONTAL
JOIST BEARING ELEVATION
JOINT
KIPS
KIPS PER SQUARE FOOT
KIPS PER SQUARE INCH
LONG
LONG LEG HORIZONTAL
LONG LEG OUTSTANDING
MIDDLE OF SLAB
MIDDLE OF WALL
MANUFACTURER or
MATERIAL
MECHANICAL
METAL
PRECAST
PRE-STRESSED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PLUMBING
RADIUS
REINFORCED or REINFORCING
REQUIRED
SLAB-ON-GRADE
STEPPED FOOTING
SECTION
SHEET
STANDARD
STIRRUP
STEEL
STRUCTURAL
TOP
TOP OF STEEL
TEMPERATURE
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WORKING POINT
WELDED WIRE FABRIC
CMU
ELEV.
J.B.E.
K.S.F.
K.S.I.
MANUF.
PSF
PSI
REINF.
U.O.N.
VERT.
W.P.
W.W.F.
S.O.G.
S.F.
SECT.
SHT.
STD.
STIR.
STL.
STRUCT.
T.
T.O.S.
TEMP.
TYP.
M.O.S.
M.O.W.
MATL.
MECH.
MTL.
P.C.
P.S.
PLUMB.
R.
REQD.
FLR.
FTG.
H.C.
HK.
HORIZ.
JT.
K
LG.
LLH
LLO
DET.
DIA.
DWG.
E.F.
E.W.
EA.
EL.
ELEC.
EXIST.
EXP.
F.O.
F.R.
FIN.
B.
B.D.
BLDG.
BM.
BRCG.
BRDG.
C.G.
C.I.P.
CLR.
COL.
CONC.
CONT.
COORD.
w/ Ø
CL
o/c
A.B.
ARCH.
MANUFACTURER'S
ACI
ASTM
AMERICAN CONCRETE INSTITUTE
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
CANT. CANTILEVER
Pc PIECE
SCHED. SCHEDULE
GALV.
GD.
GALVANIZED
GRADE
DWL. DOWEL
ENG. ENGINEER
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
BTWN. BETWEEN
SIM. SIMILAR
SL SLOPE
MAX.
MIN.
MAXIMUM
MINIMUM
N.T.S.
OSB
NOT TO SCALE
ORIENTED STRAND BOARD
D.
DBL.
DIAG.
DEEP or DEPTH
DOUBLE
DIAGONAL
EMB. EMBED or EMBEDMENT
W. WIDE or WIDTH
STIFF. STIFFENER
REF. REFERENCE
PROJ. PROJECTION
EQ. EQUAL
SPA. SPACE
B.E.J. BUILDING EXPANSION JOINT
G.C. GENERAL CONTRACTOR
F.L. FULL LENGTH
ga GAGE
ADJ. ADJACENT
BRG. BEARING
REVISIONREV.
C.J.P. COMPLETE JOINT PENETRATION
LSH
LSV
LONG SIDE HORIZONTAL
LONG SIDE VERTICAL
EQUIV. EQUIVALENT
LONG LEG VERTICALLLV
SHORT LEG OUTSTANDINGSLO
POWDER ACTUATED FASTENERPAF
STEEL JOIST INSTITUTES.J.I.
PRE-ENGINEERED BUILDINGPEB
S.D.I. STEEL DECK INSTITUTE
E.O. EDGE OF
CONN. CONNECT or CONNECTION
P.T. PRESSURE TREATED
MASONRYMAS.
STRUCTURAL STEEL
ARCHITECTURALLY EXPOSEDAESS
SEISMIC EXPANSION JOINTS.E.J.
A.R. ANCHOR ROD
DECK ASSEMBLY
SLOPED INTEGRAL ROOFS.I.R.D.A.
POST-TENSIONEDP/T
POUNDS PER LINEAR FOOTPLF
OPP. OPPOSITE
SQUARESQ.
STRUCTURAL ABBREVIATION LIST:
SPECIFIED CONCRETE COVER FOR CAST-IN-PLACE
NONPRESTRESSED CONCRETE MEMBERS
CONCRETE EXPOSURE MEMBER REINFORCEMENT
SPECIFIED
COVER (IN.)
CAST AGAINST AND
PERMANENTLY IN
CONTACT WITH GROUND
ALL ALL 3
EXPOSED TO WEATHER
OR IN CONTACT
WITH GROUND
ALL
#6 THROUGH #18 BARS 2
#5 BAR, W31 OR
S31 WIRE AND
SMALLER
1 1/2
#14 AND #18 BARS 1 1/2
#11 BAR AND SMALLER 3/4
BEAMS, COLUMNS,
PEDESTALS AND
TENSION TIES
PRIMARY REINFORCEMENT,
STIRRUPS, TIES, SPIRALS
AND HOOPS
1 1/2
SLABS, JOISTS
AND WALLSNOT EXPOSED TO
WEATHER OR
IN CONTACT WITH
GROUND
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE
BAR
SIZE
Fy =
60 KSI
TENSION BARS COMP. BARS
f'c = 3000 PSI f'c = 4000 PSI f'c = 5000 PSI f'c = ALL
REGULAR
CLASS
A
TOP
CLASS
B A B
REGULAR
CLASS
A B
REGULAR
CLASS
A B
TOP
CLASS
A B
TOP
CLASS
A B
17" 22" 22" 28" 15" 19" 13" 17"19" 25" 17" 22"#3 12"
22" 29" 29" 38" 19" 25" 17" 23"25" 33" 23" 29"#4 15"
28" 36" 36" 47" 24" 31" 22" 28"31" 41" 28" 36"#5 19"
33" 43" 43" 56" 29" 37" 26" 34"37" 49" 34" 44"#6 23"
48" 63" 63" 81" 42" 54" 38" 49"54" 71" 49" 63"#7 27"
55" 72" 72" 93" 48" 62" 43" 56"62" 81" 56" 72"#8 30"
62" 81" 81" 105" 54" 70" 48" 63"70" 91" 63" 81"#9 34"
70" 91" 91" 118" 61" 79" 54" 71"79" 102" 71" 92"#10 39"
78" 101" 101" 131" 67" 87" 60" 78"87" 114" 78" 102"#11 43"
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE NOTES:
1. THESE NOTES SHALL BE USED FOR ALL SPLICES, UNLESS NOTED OTHERWISE ON DRAWINGS.
2. TOP BARS ARE HORIZONTAL BARS, SPLICED SO THAT 12" OR MORE OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE
REINFORCING BAR.
3. CLASS A SPLICES MAY BE USED ONLY WHEN 50% OR LESS OF THE BARS ARE SPLICED WITHIN THE LAP SPLICE LENGTH.
4. CLASS B SPLICES SHALL BE USED FOR ALL SPLICES IN SLABS, BEAMS, JOISTS, WALLS, MOMENT RESISTING COLUMNS, AND JAMB
COLUMNS, UNLESS THEY MEET THE REQUIREMENTS OF NOTE #2 ABOVE.
5. TIES AND STIRRUPS SHALL NOT BE SPLICED.
6. FOR ALL LIGHTWEIGHT CONCRETE, LAP LENGTHS SHALL BE MULTIPLIED BY 13.
7. THE BAR LAP SPLICE LENGTHS SHALL BE MULTIPLIED BY 1.5 WHEN EITHER OF THE FOLLOWING IS TRUE:
A. CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN ONE BAR DIAMETER, CLEAR COVER IS LESS THAN ONE BAR DIAMETER AND STIRRUPS OR TIES ALONG THE LENGTH OF THE SPLICE ARE LESS THAN THE CODE MINIMUM.
B. CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN 2 BAR DIAMETERS AND CLEAR COVER IS LESS THAN ONE BAR
DIAMETER.
f'c = 3500 PSI
REGULAR
CLASS
A
TOP
CLASS
B A B
16" 21" 21" 26"
21" 27" 27" 36"
26" 34" 34" 44"
31" 40" 40" 52"
45" 59" 59" 75"
51" 67" 67" 87"
58" 75" 75" 98"
65" 85" 85" 110"
73" 94" 94" 122"
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
F*T
O N*
N
OI T CURT
S
N O
C*
RO
D
C
B
A
E
D
C
B
A
E
09/01/2026
100% SUBMITTAL
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/2
/2
:0
:1
P
M A u to d e s k D o c s /2
-0
I O
W C
S S m it h fi e ld H
S W e ld in g /2
-0 v
S m it h fi e ld H
S W e ld in g B u ild in g
S
T R
U C
.r v t
S-001
.3
-F
M L S
M S
W
D W
S
S T
R U
C T
U R
A L
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.COM
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
P: 804.464.4111
RICHMOND, VIRGINIA 23294
2821 EMERYWOOD PARKWAY SUITE 300
21.374-F
09/01/2026
IF
B
-0
(E ) H
SS8x 8x1
/4
(E ) H
SS8x 8x1
/4
(E ) H
SS8x 8x1
/4
(E ) H
SS8x 8x1
/4
(E ) H
SS8x 8x1
/4
(E) HSS8x8x1/4
(E ) H
SS8x 8x1
/4
(E ) H
SS8x8 x1
/4
(E ) H
SS8x 8x1
/4
(E ) H
SS8x 8x1
/4
(E) CF5.5
(E) CF6.5 (E) CF6.5 (E) CF6.5 (E) CF6.5
(E) CF4.0
(E) CF5.5
(E) CF5.5 (E) CF5.5
(E) CF5.5
(E) WF1.5
(E
W
F 2.
(E) WF1.5
(E) WF2.0
(E
W F
1.
(E
W F
1.
EXISTING CMU
WALL (TYP.)
EXISTING WALL
FOOTING (TYP.)
(-1 '-4
(-0 '-8
(-0 '-8
(-1 '-4
NOTE F1 (TYP.)
(-2'-0"±)
NOTES F3
AND F4
(-2'-0"±)
(-2 '-0"±)
(-1 '-4"±)
(-0 '-8"±)
(-2'-0"±)
(-1'-4"±)
(-0'-8"±)
NOTE F5
NOTE F5
B
C
1 2 3 4 5
(E) TS
NOTE F2
CJ
1' -6
/2
'-4
1'-6 1/2" ± 26'-4" ± 26'-4" ± 26'-4" ± 26'-4" ±
1'-0" ± 2'-0 3/4" ±
22'-0" ±
S-301
1.1
B2
B1
11'-11 3/16" ±
6' -1
3/
4"
3' -1
/8
(-2'-0"±) (-2
'-0
(-2 '-0
(-0'-8"±) (-0'-8"±)
(-0 '-8
NOTES F3
AND F4
NOTES F3
AND F4
NOTES F3
AND F4
NOTE F7
A
A
FOUNDATION PLAN NOTES :
F1. EXISTING FIRST FLOOR IS A 5"± THICK CONCRETE SLAB-ON-GRADE,
REINFORCED WITH W.W.F. 6x6-W2.1xW2.1 SET 1"± CLEAR FROM TOP OF
SLAB, OVER 6 MIL. VAPOR BARRIER, OVER 4"± DEPTH OF POROUS FILL.
F2. FIRST FLOOR MUST BE A 5" THICK FIBER REINFORCED CONCRETE SLAB-
ON-GRADE, OVER 15 MIL. VAPOR RETARDER MINIMUM, OVER 4" DEPTH OF
POROUS FILL. FIBERS MUST BE FIBRALLATED SYNTHETIC MACROFIBERS
AT A DOSAGE RATE OF 3 POUNDS PER CUBIC YARD.
F3. GENERAL CUTTING AND PATCHING OF THE EXISTING SLAB IS PARTIALLY
INDICATED. SEE THE ARCHITECTURAL, MECHANICAL AND PLUMBING
DRAWINGS FOR ADDITIONAL REQUIREMENTS. PATCH EXISTING SLAB AS
SHOWN IN 'TYPICAL DETAIL OF REMOVAL AND REPAIR OF EXISTING SLAB-
ON-GRADE' ON SHEET S-501.
F4. SEE THE ARCHITECTURAL DRAWINGS FOR MASONRY WALL DEMOLITION.
EXTEND WALL DEMOLITION APPROXIMATELY 8" BELOW EXISTING FLOOR
AT DOOR OPENINGS AND FILL SOLID WITH CONCRETE FROM THE TOP OF
REMAINING WALL LEVEL WITH EXISTING SLAB.
F5. OVERHEAD COILING DOOR POST. PROVIDE HSS4x4x3/8 POST. SEE THE
ARCHITECTURAL DRAWINGS FOR DETAILS, LOCATION AND ADDITIONAL
INFORMATION.
F6. FOR THE OVERHEAD DOORS, THE GENERAL CONTRACTOR MUST CONFIRM
PROVIDED STRUCTURE IS ACCEPTABLE TO SELECTED MANUFACTURER
PRIOR TO STEEL FABRICATION AND INSTALLATION.
F7. INFILL CMU – SEE ARCHITECTURAL DRAWINGS. NEW CMU SHALL MATCH
EXISTING CMU SIZE AND SHALL BE TOOTHED INTO EXISTING MASONRY.
FOUNDATION PLAN LEGEND :
(E) WFX.X = EXISTING WALL FOOTING MARK - SEE SCHEDULE
ON THIS SHEET
(E) CFX.X = EXISTING COLUMN FOOTING MARK - SEE SCHEDULE
ON THIS SHEET
(E) SF = EXISTING STEPPED FOOTING
X = COLUMN GRID MARK
± = APPROXIMATE DIMENSION OR ELEVATION
(FIELD VERIFY)
(E) = EXISTING
± = EXISTING DIMENSION OR ELEVATION
(FIELD VERIFY)
= TOP OF EXISTING FOUNDATION ELEVATION -
MEASURED FROM REFERENCE ELEVATION 0'-0"
(-X'-X"±)
= EXISTING COLUMN GRID MARKX
CJ = SLAB-ON-GRADE CONTROL JOINT - SEE
TYPICAL DETAIL ON SHEET S-501
(E) TS = EXISTING THICKENED SLAB
= CHANGE IN EXISTING SLAB ELEVATION
AREA OF
WORK
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
F*T
O N*
N
OI T CURT
S
N O
C*
RO
D
C
B
A
E
D
C
B
A
E
09/01/2026
100% SUBMITTAL
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/2
/2
:0
:1
P
M A u to d e s k D o c s /2
-0
I O
W C
S S m it h fi e ld H
S W e ld in g /2
-0 v
S m it h fi e ld H
S W e ld in g B u ild in g
S
T R
U C
.r v t
S-101
.3
-F
M L S
M S
W
D W
S
F O
U N
D A
T
IO
N P
L A
N
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
1/4" = 1'-0"
PARTIAL FOUNDATION PLAN
PLAN NORTH
THE INFORMATION REGARDING THE EXISTING CONSTRUCTION WAS OBTAINED FROM THE
RECORD DRAWINGS PREPARED BY RANCORN WILDMAN KRAUSE ARCHITECTS DATED
MARCH 16, 1979. ALL INFORMATION SPECIFYING EXISTING CONDITIONS MUST BE VERIFIED BY
THE GENERAL CONTRACTOR. THE AFOREMENTIONED DRAWINGS WILL BE MADE AVAILABLE
TO THE CONTRACTOR UPON REQUEST.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.COM
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
P: 804.464.4111
RICHMOND, VIRGINIA 23294
2821 EMERYWOOD PARKWAY SUITE 300
21.374-FNOT TO SCALE
KEY PLAN
09/01/2026
IF
B
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E
H
(E) W18x40 (E) W16x31 (E) W16x31 (E) W16x31
(E) W16x26(E) W16x26(E) W16x26(E) W16x31
B
C
1 2 3 4 5
L4
+16'-8"±
+15'-0"±
NOTE F
NOTE C (TYP.)
NOTE F
N O
T E
F
B
L-
NOTE E
NOTE E
1.1
B2
B1
N O
T E
D
L4
B
FRAMING PLAN NOTES :
A. SEE THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN..
B.. FOR THE STRUCTURAL NOTES AND ABBREVIATIONS SEE SHEET S-001.
C. MASONRY WALL OPENING. SEE THE ARCHITECTURAL DRAWINGS FOR
SIZE, LOCATION AND DETAILS. FOR REQUIRED LINTELS SEE 'TYPICAL
DETAILS ON SHEET S-501.
D. HSS8x4x3/8 (LSV) BEAM SPANNING OVER AND SUPPORTING OVERHEAD
COILING DOOR. COORDINATE STEEL BEAM AND POST LOCATIONS WITH
THE ARCHITECTURAL DRAWINGS AND EXISTING DOOR.
E. EXISTING 1 1/2" x 22 GAGE ± ROOF STEEL DECK.
F. SEE 'TYPICAL SUPPORT DETAIL FOR MASONRY WALL AT NEW DOOR
OPENINGS' ON SHEET S-501.
FRAMING PLAN LEGEND :
+XX'-XX"± = EXISTING JOIST BEARING ELEVATION (J.B.E) -
MEASURED FROM REFERENCE ELEVATION 0'-0"±
± = APPROXIMATE DIMENSION OR ELEVATION
(FIELD VERIFY)
(E) = EXISTING
± = EXISTING DIMENSION OR ELEVATION
(FIELD VERIFY)
L-X = LINTEL MARK - SEE DETAIL ON SHEET S-501
= EXISTING CANTILEVER BEAM TO COLUMN CONNECTION
= CHANGE IN EXISTING ROOF ELEVATION
= L2x2x1/4 CROSS BRACING
= EXISTING COLUMN GRID MARKX
L4 = L4x4x1/4
X = SPECIAL CONNECTION MARK - SEE DETAIL
ON SHEET S-501
AREA OF
WORK
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
F*T
O N*
N
OI T CURT
S
N O
C*
RO
D
C
B
A
E
D
C
B
A
E
09/01/2026
100% SUBMITTAL
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/2
/2
:0
:1
P
M A u to d e s k D o c s /2
-0
I O
W C
S S m it h fi e ld H
S W e ld in g /2
-0 v
S m it h fi e ld H
S W e ld in g B u ild in g
S
T R
U C
.r v t
S-141
.3
-F
M L S
M S
W
D W
S
R O
O F
F R
A M
IN
G
P L A
N
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
1/4" = 1'-0"
ROOF FRAMING PLAN
PLAN NORTH
THE INFORMATION REGARDING THE EXISTING CONSTRUCTION WAS OBTAINED FROM THE
RECORD DRAWINGS PREPARED BY RANCORN WILDMAN KRAUSE ARCHITECTS DATED
MARCH 16, 1979. ALL INFORMATION SPECIFYING EXISTING CONDITIONS MUST BE VERIFIED BY
THE GENERAL CONTRACTOR. THE AFOREMENTIONED DRAWINGS WILL BE MADE AVAILABLE
TO THE CONTRACTOR UPON REQUEST.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.COM
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
P: 804.464.4111
RICHMOND, VIRGINIA 23294
2821 EMERYWOOD PARKWAY SUITE 300
21.374-F
NOT TO SCALE
KEY PLAN
09/01/2026
IF
B
EXISTING WALL BEYOND
SLOPE EXTERIOR
PORTION OF SLAB
TO DRAIN
SEE THE ARCH. DWGS.
EXTERIOR SLAB -
SEE THE CIVIL DWGS.
EXISTING CMU (TYP.)
EXISTING FOOTING
SEE 'TYPICAL DETAIL
OF ADDED SLAB
REINFORCING AT
EXTERIOR DOORS'
ON SHEET S-501
EXISTING BRICK
VENEER
VAPOR BARRIER
POROUS FILL
EXISTING
VAPOR BARRIER
EXISTING POROUS FILL
EXISTING SLAB-ON-GRADE
SEE 'TYPICAL REPAIR AND
REMOVE OF EXISTING
SLAB-ON-GRADE DETAIL'
ON SHEET S-501CONT. GALV. L2x2x1/4
WITH 1/2"Ø x 4" LONG
HEADED STUDS SPACED
AT 24"o/c
OVERHEAD DOOR -
SEE THE ARCH. DWGS.
FOR EXACT SIZE
AND LOCATION
SEE THE ARCH.DWGS.
8"
FILL SOLID WITH
GROUT BELOW FLOOR
8"
CONT. BOND BREAKER
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
F*T
O N*
N
OI T CURT
S
N O
C*
RO
D
C
B
A
E
D
C
B
A
E
09/01/2026
100% SUBMITTAL
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/2
/2
:0
:1
P
M A u to d e s k D o c s /2
-0
I O
W C
S S m it h fi e ld H
S W e ld in g /2
-0 v
S m it h fi e ld H
S W e ld in g B u ild in g
S
T R
U C
.r v t
S-301
.3
-F
M L S
M S
W
D W
S
F O
U N
D A
T
IO
N S
E C
T
IO
N S
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
3/4" = 1'-0"S-301
SECTION1
09/01/2026
IF
B
1/
2"
1/ 2"
2" 2"
3"3"
A
1/4
1/4
1/4
1/4
B
1/4
TYP.
1'-2"± 1'-2"±
EXISTING CMU
WALL
(E) 8"± CMU (E) 8"± CMU (E) 8"± CMU (E) 10"± CMU
EXISTING VENEER
MASONRY
(E) 10"± CMUEXISTING VENEER
MASONRY
EXISTING STEEL
ROOF DECK
EXISTING JOIST (TYP.)
DOOR OPENING WIDTH -
8" MIN.
BEARING (TYP.)
3/4" MAX.
TYPICAL SUPPORT DETAIL FOR MASONRY WALL AT NEW INTERIOR DOOR OPENINGS TYPICAL DETAIL AT NEW LOUVERS IN EXISTING WALL TYPICAL L-1 LINTEL DETAIL
SPECIAL CONNECTIONS
TYPE TYPE
OPENING
NOT TO SCALE
L3-1/2x3-1/2x3/8
OPENINGS LESS THAN 4'-0"
SEE THE ARCH. DWGS.
OPENINGS 4'-0" TO 6'-8"
L5x3-1/2x3/8 (LLV)
OPENINGS 6'-9" TO 7'-5"
L6x3-1/2x3/8 (LLV)
NOT TO SCALE
VENEER MASONRY -
SEE THE ARCH. DWGS.
GALV. L3 1/2x3 1/2x3/8
GALV. L7x4x3/8 (LSH)
NOTE:
THIS DETAIL APPLIES TO
LOUVER OPENINGS LESS
THAN 2'-0" WIDE.
COORDINATE LOUVER
LOCATION WITH THE
ARCHITECTURAL AND
MECHANICAL DRAWINGS.
NOT TO SCALE
VENEER MASONRY -
SEE THE ARCH. DWGS.
SHORING BEAM - SEE
GENERAL NOTE #4 ON
SHEET S-001
GAVL. W8x28
GALV. BOTTOM PL5/15 -
LENGTH OF PLATE = WIDTH
OF MASONRY OPENING
MINUS 1 1/2" (3/4" CLEAR
EACH END)
1/2"Ø x 4" LONG HEADED STUDS AT 24"o/c - FILL
CELLS SOLID WITH GROUT
AT STUDS
NOT TO SCALE
L2 1/2x2 1/2x1/4
CROSS BRACING -
SEE PLAN; PROVIDE
1/4" GUSSET PLATE
CONNECTIONS
L4x4x1/4 - FIELD WELD
TO EXISTING JOIST
BOTTOM CHORD EACH END
CAP PL1/4
POST - SEE PLAN
BEAM - SEE PLAN
BOTTOM OF STEEL - COORDINATE
WITH EXISTING DOOR AND
MANUFACTURER REQUIREMENTS
SEE 'TYPICAL DETAIL
AT CONCENTRATED
LOADS ON EXISTING
JOISTS' ON THIS SHEET
PL3/4x11x6 w/
2 - 1/2" DIA. HAS U 55
THREADED RODS w/
HILTI HIT-HY 200 V3
ADHESIVE (EMB. = 3 1/2" MIN.)
EXISTING 5"± THICK
CONCRETE SLAB-
ON-GRADE (FIELD
VERIFY THICKNESS)
REMOVAL AND REPAIR OF EXISTING SLAB-ON-GRADE
CLEAN SURFACE OF EXISTING SLAB
AND PAINT WITH BONDING COMPOUND
PRIOR TO PLACING NEW CONCRETE
NEW 5" MINIMUM CONC. SLAB-ON-GRADE -
MATCH THICKNESS OF EXISTING SLAB
SURFACE OF EXISTING SLAB
SHALL BE SQUARE AND SOUND
SAW-CUT 1" DEEP AT
PERIMETER OF AREA
TO BE REMOVED
AND BREAK OUT
EXISTING SLAB
EXISTING SLAB NEW SLAB
#4 x 1'-4" AT 12"o/c - DOWEL INTO
EXISTING SLAB (6" EMB.) USING
HILTI HY 200 SYSTEM (OR EQUIV.)
E Q
E
Q
MIN.
0'-8"
SIZE TO SUIT
MASONRY OPENING -
EXISTING CMU WALL
BRG. PL1/4x7x7 WITH 1/2"Ø X 4"LG.
HEADED STUD SET AND LEVELED
IN A FULLY GROUTED BLOCK CELL
3/16 2
STEEL BEAM LINTEL
BOTTOM PLATE AND
MASONRY INFILL
(WHERE SHOWN)
REMOVE EXISTING MASONRY AT
JAMBS AND "TOOTH" IN WITH NEW
CMU AS SHOWN
GROUT CELLS SOLID THREE
COURSES BELOW BEAM BEARING
PARALLEL TO WALLCONTROL JOINT (CJ)
CONTRACTOR HAS THE OPTION TO FORM
CONTROL JOINTS USING PREMOLDED PLASTIC,
HARDBOARD OR FIBERBOARD STRIPS.
SLAB-ON-GRADE
CL SAW-CUT JOINT
SAW-CUT DEPTH =
ONE-QUARTER OF
SLAB THICKNESS 'T'
VAPOR RETARDER
(WHERE OCCURS) -
SEE PLAN
SAW-CUT WIDTH = 1/8"
PLAN VIEW AT ADDED SLAB REINFORCING
AT EXTERIOR DOORS
E X
T E
R
IO
R W
A
LL
S E
E O
T H
E R
D
E T
A
IL
S
SEE THE
ARCH. DWGS.
2" CLR.
#4 CONT.
MIDDLE
OF SLAB
BOND BREAKER
(TYP.)
SLAB-ON-GRADE #4 WITH STD. 180°
HK. MIDDLE OF
SLAB, EACH SIDE
OF OPENING
#4 A
T
6" o/ c T
W
IT
H S
T D
. 1
H
K
2" C
LR
(T
YP.)
"24
APPLIED
LOAD
NOTE 3
3/16
EXISTING JOIST
TOP CHORD
HANGING LOAD
(NOTE 2)
EXISTING JOIST
BOTTOM CHORD
4" MAX.
PANEL POINT
WASHER
PL3/16x2 SQ.
NOTE 1
NOTE 2
AT PANEL POINTSBETWEEN PANEL POINTS
4" MAX.
NOTE 1
WASHER
PL3/16x2 SQ.
ADDED ANGLES
(SEE NOTE 3)
NOTE 2
NOTES:
1. HANGER RODS - SEE THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.
2. POSITION HANGER RODS ON JOIST CENTERLINE BETWEEN BOTTOM CHORD ANGLES. "C" CLAMP
CONNECTIONS ARE NOT ALLOWED.
3. WHERE CONCENTRATED LOADS ARE APPLIED TO TOP CHORDS OR HUNG FROM BOTTOM CHORDS
BETWEEN PANEL POINTS REINFORCE EXISTING JOIST WITH DOUBLE L2x2x1/4.
NOTE:
THIS DETAIL IS FOR ALL LOADS
WHICH EXCEED 100 POUNDS
L2x2x1/4 - LOCATE
AT TOP CHORD
PANEL POINTS
3/16 1
TYP.
BRACE AS FOLLOWS:
L2x2x1/4 FOR MAX. LENGTH = 6'-0" L3x3x1/4 FOR MAX. LENGTH = 9'-0"
NOTE:
LOCATE SUPPORT
FRAMES AT EACH
JOIST OR SPACED
AT 6'-0"o/c MAX.
PARALLEL TO EXISTING JOISTS
PARTITIONS STOPPING BELOW EXISTING JOISTS
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
F*T
O N*
N
OI T CURT
S
N O
C*
RO
D
C
B
A
E
D
C
B
A
E
09/01/2026
100% SUBMITTAL
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/2
/2
:0
:1
P
M A u to d e s k D o c s /2
-0
I O
W C
S S m it h fi e ld H
S W e ld in g /2
-0 v
S m it h fi e ld H
S W e ld in g B u ild in g
S
T R
U C
.r v t
S-501
.3
-F
M L S
M S
W
D W
S
S E
C T
IO
N
S A
N D
T Y
P
IC
A L D
E T
A
IL
S
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
NOT TO SCALE
TYPICAL SLAB-ON-GRADE DETAILS
3/4" = 1'-0"
TYPICAL STEEL BEAM BEARING ON EXISTING MASONRY DETAIL
THE INFORMATION REGARDING THE EXISTING CONSTRUCTION WAS OBTAINED FROM THE
RECORD DRAWINGS PREPARED BY RANCORN WILDMAN KRAUSE ARCHITECTS DATED
MARCH 16, 1979 AND BY FIELD INVESTIGATION. ALL INFORMATION SPECIFYING EXISTING
CONDITIONS MUST BE VERIFIED BY THE GENERAL CONTRACTOR. THE AFOREMENTIONED
DRAWINGS WILL BE MADE AVAILABLE TO THE CONTRACTOR UPON REQUEST.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.COM
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
P: 804.464.4111
RICHMOND, VIRGINIA 23294
2821 EMERYWOOD PARKWAY SUITE 300
21.374-F
3/4" = 1'-0"
TYPICAL DETAIL AT CONCENTRATED LOADS ON EXISTING JOISTS
3/4" = 1'-0"
TYPICAL NON-BEARING MASONRY PARTITION DETAIL
09/01/2026
IF
B
WD
W D
PROJECT BASIC DESCRIPTION
THE PROJECT INCLUDES THE INTERIOR RENOVATION/EXPANSION OF A 3,574 SF SPACE WITHIN AN EXISTING BUILDING. THE SPACE IS ONE (1) STORY AND WILL CONSIST OF A WELDING LAB, A
CLASSROOM, A STORAGE SPACE, AND MENS/WOMENS LOCKER ROOMS. DESIGN OCCUPANT LOAD
IS 73. THE CODE OCCUPANT LOAD IS 80 MAX. ALL EGRESS COMPONENTS ARE BASED OFF OF THIS
MAXIMUM CODE DERIVED OCCUPANT LOAD.
A. APPLICABLE CODES
ORIGINAL 1975 VIRGINIA STATEWIDE BUILDING CODE
1. BUILDING CODES: 2021 VIRGINIA CONSTRUCTION CODE (VCC)
2021 VIRGINIA MECHANICAL CODE (VMC)
2021 VIRGINIA PLUMBING CODE (VPC)
2021 VIRGINIA EXISTING BUILDING CODE (VEBC)
2023 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)
2021 VIRGINIA STATEWIDE FIRE PREVENTION CODE
2020 NFPA 70
2. ACCESSIBILITY CODE: 2021 VCC AND 2017 ICC/ANSI 117.1
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN - SEPT 15, 2010
3. ZONING ORDINANCE FOR COUNTY OF ISLE OF WIGHT, VA
4. OTHER STANDARDS: 2021 GUIDELINES FOR SCHOOL FACILITIES IN VIRGINIA'S PUBLIC
SCHOOLS
B. GROSS BUILDING AREAS
ALTERATION AREA: 3,574 SF
C. BUILDING OCCUPANCY AND CONSTRUCTION TYPE
1. PER 2021 VCC 305.1 BUILDING USE CLASSIFICATION: OCCUPANCY GROUP E "EDUCATIONAL"
2. PER 2021 VCC 602.2.2 CONSTRUCTION TYPE: TYPE IIB UNPROTECTED (SPRINKLERED)
D. FIRE PROTECTION SYSTEMS
1. BUILDING IS NOT SPRINKLERED
2. FIRE EXTINGUISHER PER 2021 VCC 906.1
E. FIRE RESISTANCE RATING REQUIREMENTS
PER 2021 VCC TABLE 601
EXTERIOR BEARING WALLS 0 HR.
EXTERIOR NON-BEARING WALLS 0 HR.
INTERIOR BEARING WALLS 0 HR.
INTERIOR NON-BEARING WALLS 0 HR.
STRUCTURAL FRAME 0 HR.
FLOOR/CEILING CONSTRUCTION 0 HR.
ROOF/CEILING CONSTRUCTION 0 HR
EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (PER 2021 VCC TABLE 705.5):
LESS THAN 10' 1 HR
GREATER OR EQUAL TO 10' 0 HR
F. AREA ALLOWANCE PER OCCUPANT (PER 2021 VCC TABLE 1004.5)
1. EDUCATIONAL SHOP AND VOCATIONAL 50 SF NET
2. STORAGE AREAS 300 SF GROSS
3. EDUCATIONAL CLASSROOM AREAS 20 SF NET
4. LOCKER ROOMS 50 SF GROSS
G. MEANS OF EGRESS
PER 2021 VCC 1005.3.1 EGRESS WIDTH PER OCCUPANT (WITHOUT SPRINKLER SYSTEM)
STAIRWAYS: 0.3 PER OCCUPANT
OTHER EGRESS COMPONENTS 0.2 PER OCCUPANT
PER 2021 VCC TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER
STORY:
1-500 OCCUPANT LOAD / MINIMUM NUMBER OF EXITS: 2
PER 2021 VCC TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE:
OCCUPANCY GROUP E, 200’ WITHOUT SPRINKLER
THE OCCUPANT LOAD PERMITTED IN ANY BUILDING, OR PORTION THEREOF, IS PERMITTED
TO BE INCREASED FROM THAT NUMBER ESTABLISHED FOR THE OCCUPANCIES IN TABLE
1004.5, PROVIDED THAT ALL OTHER REQUIREMENTS OF THE CODE ARE MET BASED ON
SUCH MODIFIED NUMBER AND THE OCCUPANT LOAD DOES NOT EXCEED ONE OCCUPANT
PER 7 SQUARE FEET (0.65 m2) OF OCCUPIABLE FLOOR SPACE.
DESIGN OCCUPANCY 73 OCCUPANTS
CODE OCCUPANCY 80 OCCUPANTS
EGRESS CAPACITY REQUIRED 16.2"
PROVIDED 108"
H. PLUMBING FIXTURES:
EMERGENCY EYEWASH STATIONS SHALL BE INSTALLED PER 2021 VPC 411 AND CONFORM
TO ISEA Z358.1 MEETING OSHA SAFETY STANDARDS
SMITHFIELD HIGH SCHOOL BUILDING CODE DESIGN SUPPORTING DATA
384 SF
NEW
WELDING
STORAGE
B104 1/ 1
2062 SF
NEW
WELDING
LAB
B102 42/ 37
106 SF
WOMEN'S
LOCKER
RM
B106 2/ 1
582 SF
WELDING
CLASSROOM
B111 29/ 29
(71'-0")
(46'-0")
0 50
FE
FE
(39'-0")
(70'-0")
106 SF
MEN'S
LOCKER
RM
B107 2/ 1
THIS AREA NOT IN
CONTRACT
3 1
FE
215 SF
WORKROOM
B100 4/ 4
0 4
(28'-0")
FE
FE
THIS AREA NOT IN
CONTRACT
SEE PLUMBING AND
ELECTRICAL DRAWINGS FOR
WORK THIS AREA
FE
FE
LIFE SAFETY KEY NOTES
EXISTING FIRE EXTINGUISHER
EXISTING EMERGENCY EYEWASH STATION
EXISTING STAIR LEADS TO EXISTING UNOCCUPIED EQUIPMENT PLATFORM
NEW FIRE EXTINGUISHER. MOUNT SO HANDLE IS WITHIN 48" OF REACH OR LESS
NEW EMERGENCY EYEWASH STATION
(APPLIES TO THIS SHEET ONLY)
LIFE SAFETY PLAN LEGEND
APPROXIMATE MAXIMUM TRAVEL DISTANCE
FE WALL MOUNTED FIRE EXTINGUISHER- REF SPECIFICATIONS
48/26
DESIGN OCCUPANCY
CODE OCCUPANCY
EGRESS CAPACITY IN PERSONS FOR OPENING SHOWN
CALCULATED OCCUPANCY LOAD AT EXIT LOCATION
EXISTING BUILDING
Lic. No. 10748
JEFFREY A HARRIS
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
2026-09-01
/3
/2
:2
:3
P
M A u to d e s k D o c s /2
-0 I
O W
C S
S m it h fi e ld
H S
W e ld in g /2
-0 v
S m it h fi e ld
H S
W e ld in g B u ild in g
A R
C H
.r v t
LS101
-0
J A
H
M M
H
J A
H
IF
B
-0
L
IF
E S
A F
E T
Y F
L O
O R
P L A
N
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S
T
U R
N E
R D
R
IV
E
S M
IT
H
F
IE
L D
V
A
IS
L E
O F
W
IG
H T
C O
U N
T Y
S C
H O
O L S
S M
IT
H
F
IE
L D
H
IG
H S
C H
O O
L W
E L D
IN
G
L A
B R
E N
O V
A T
IO
N
S -0
-0
SCALE:LS101 1/8" = 1'-0"
A1 LIFE SAFETY FLOOR PLAN
/4
TYP
TYP
2'
8" ±
4' - 0" ±
5' - 5 3/8" ±
14' - 6 1/4" ±
7'
1'
SEE PLUMBING AND
ELECTRICAL DRAWINGS FOR
WORK THIS AREA
/2
23 23
11' - 0"
/4
9' - 1" ±
3' - 9" ±
4' - 3" ±
10' - 0" ±
12' - 6 1/8" ±
DEMOLITION KEY NOTES
1 REMOVE ISLAND AND PATCH/REPAIR/PREP CONC SLAB TO MATCH EXISTING ADJACENT
REMOVE HOLLOW METAL FRAME, DOOR AND HARDWARE COMPLETE. PREPARE OPENING FOR
INSTALLATION OF NEW CMU TO MATCH EXIST ADJACENT TO REMAIN.
REMOVE EXISTING STUD WALL INCLUDING DOOR & FRAME WITHIN PARTITION COMPLETE. PATCH, REPAIR & PREP CONC SLAB FOR NEW FINISH. PATCH INTERSECTION AT WALLS TO REMAIN.
REMOVE RUBBER BASE COMPLETE AND PREP FOR NEW BASE INSTALLATION.
SAWCUT AND REMOVE PORTION OF EXISTING EXTERIOR BRICK VENEER AND CMU WALL TO THE
APPROXIMATE EXTENT AS INDICATED AND AS REQUIRED FOR INSTALLATION OF NEW OVERHEAD
DOOR AS INDICATED IN SECTIONS & DETAILS - REMOVE WALL DOWN TO 8" BELOW FINISH FLOOR.
SAWCUT AND REMOVE PORTION OF EXISTING CMU & BRICK VENEER WALL TO ALLOW FOR NEW
WORK. SALVAGE BRICK VENEER. PREPARE OPENING FOR INSTALLATION OF NEW OVERHEAD DOOR
SYSTEM.
REMOVE AND SALVAGE EXISTING TACKBOARD, TACKSTRIP COMPLETE. TURN OVER TO OWNER FOR
REUSE PATCH/REPAIR/PREP DAMAGED WALL AREAS.
CAREFULLY REMOVE AND SALVAGE EXISTING STOREFRONT SYSTEM COMPLETE INCLUDING GLAZING
FRAME, DOOR AND HARDWARE AND TURN OVER TO OWNER FOR FUTURE USE. PATCH AND REPAIR
ANY DAMAGE TO EXISTING WALLS AND FLOOR SLAB TO REMAIN & PREPARE TO RECEIVE NEW WORK.
EXISTING STEEL STAIR TO REMAIN
(APPLIES TO THIS SHEET ONLY)
REMOVE EXISTING STUD FRAMED PARTITION COMPLETE. PATCH & REPAIR CONC SLAB. PATCH
INTERSECTION AT WALLS TO REMAIN.
REMOVE EXISTING DOOR AND HARDWARE COMPLETE. TURN OVER TO OWNER. EXISTING DOOR
FRAME TO REMAIN. REPAIR ANY DAMAGE TO FRAME & PREPARE TO RECEIVE NEW DOOR AND PAINT.
REMOVE EXISTING CUBBIES/FURNITURE AND TURN OVER TO OWNER.
SAWCUT AND REMOVE PORTION OF EXIST CMU WALL TO THE EXTENT INDICATED AND 8" BELOW SLAB.
PATCH & REPAIR CONC SLAB. PATCH INTERSECTION AT WALLS TO REMAIN.
REMOVE EXISTING CARPET, MASTIC AND TRANSITION STRIP COMPLETE. PATCH/REPAIR CONCRETE AS
NEEDED TO RECEIVE NEW FLOOR FINISH.
REMOVE EXISTING SURFACE MOUNTED PLYWOOD BLOCKING. PATCH/REPAIR/PREP WALL FOR NEW
FINISH.
SAWCUT AND REMOVE PORTION OF EXISTING WALL INCLUDING DOOR AND FRAME TO ALLOW FOR
NEW WORK. PREPARE OPENING FOR INSTALLATION OF NEW LINTEL, DOOR AND FRAME (COORDINATE
WITH DOOR SCHEDULE)
REMOVE EXIST VCT AND MASTIC COMPLETE TO EXTENT INDICATED. PATCH/ REPAIR CONCRETE AS
NEEDED TO RECEIVE NEW FLOOR FINISH.
PREPARE EXISTING EPOXY PAINTED FLOOR TO RECEIVE NEW FINISH COAT. EXTENT AS INDICATED BY
HATCHING. REFER TO DEMO HATCH LEGEND.
19 REMOVE SMALL PORTION OF WALL AS REQUIRED FOR SANITARY CONNECTION OF EYEWASH. REF
PLUMBING DWGS FOR ADDITIONAL INFORMATION.
EXISTING FLOOR FINISH TO REMAIN
REMOVE EXISTING CONCRETE SIDEWALK TO APPROXIMATE EXTENTS INDICATED. PREPARE GRADE
TO RECEIVE NEW CONCRETE PAVEMENT
REMOVE EXISTING CONCRETE CURB TO APPROXIMATE EXTENTS INDICATED. COORDINATE EXTENTS
WITH NEW CONCRETE PAVEMENT
PREPARE AREA TO RECEIVE NEW CONCRETE PAVEMENT. COORDINATE EXTENTS WITH DETAIL
SAWCUT & REMOVE EXISTING CONCRETE FLOOR SLAB AS REQUIRED FOR UNDER SLAB PLUMBING
WORK - APPROXIMATE EXTENT AS INDICATED - REF PLUMB FOR ADDITIONAL INFORMATION
REMOVE RUBBER BASE COMPLETE TO EXTENT INDICATED AND PREP FOR NEW BASE INSTALLATION
B5 / A-10123
EXISTING WALL AND/OR
DOOR TO BE DEMOLISHED
OR REMOVED
EXISTING WINDOW TO BE
REMOVED
EXISTING WALL, WINDOW,
AND/OR DOOR TO REMAIN
A. REFER TO STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION
INFORMATION
B. PLAN DIMENSIONS FOR EXISTING CONDITIONS ARE TO FACE OF MASONRY, FACE OF DEMOUNTABLE PARTITION, OR CENTERLINE OF STRUCTURAL FRAMING, UNLESS OTHERWISE NOTED. THICKNESS OF MASONRY BASED ON NOMINAL SIZES. ALL DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION ARE APPROXIMATE: FIELD VERIFY ALL DIMENSIONS.
C. ALL DEMOLITION WORK NOTED ON THESE DRAWINGS INVOLVE THE REMOVAL OF EXISTING CONSTRUCTION UNDER THE BASE CONTRACT, AND SHALL BE COORDINATED WITH CORRESPONDING NEW WORK FLOOR PLANS AND DETAILS. REMOVE EXISTING CONSTRUCTION AS INDICATED FOR FINISH CONSTRUCTION AND NEW WORK TO CONFORM TO DETAILS.
D. DETAILS OF EXISTING CONDITIONS: ACTUAL FIELD CONDITIONS WHICH ARE CONCEALED BY EXISTING CONSTRUCTION MAY VARY SOMEWHAT FROM THOSE INDICATED IN DRAWINGS. ALL WORK THAT RELATES TO, OR IS IN ANY WAY AFFECTED BY, EXISTING CONDITIONS WHICH VARY FROM THOSE INDICATED SHALL BE MODIFIED AS REQUIRED BY FIELD CONDITIONS AND MEASUREMENTS, REPORT DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH AFFECTED
ASPECTS OF CONSTRUCTION OR DEMOLITION.
E. THE DEMOLITION DRAWINGS INDICATE MAJOR ITEMS TO BE DEMOLISHED. MISCELLANEOUS ABANDONED CONDUIT, WALL PENETRATIONS (I.E. SCREWS, NAILS, & MASONRY ANCHORS), WOOD BLOCKING, AND OTHER VARIOUS ITEMS FASTENED TO EXISTING WALL MAY NOT BE INDICATED ON THE DRAWINGS, REMOVE SUCH ITEMS THAT ARE NOT USED IN, OR CONCEALED BY, NEW WORK, PATCH AND REPAIR DAMAGE TO THE WALLS WHERE SUCH ITEMS ARE REMOVED.
F. SAWCUT AND REMOVE EXISTING CONCRETE SLAB AS REQUIRED TO ACCOMMODATE NEW STRUCTURAL, PLUMBING, AND ELECTRICAL WORK. REF STRUCTURAL, PLUMBING, & ELECTRICAL DRAWINGS. MINOR LOCATIONS MAY NOT BE INDICATED.
G. PORTIONS OR ELEMENTS (I.E. DOOR FRAMES) OF WALL OR SLAB SCHEDULED TO BE REMOVED OR SAWCUT AND
REMOVED SHALL BE DONE SO TO PREVENT DAMAGE TO ADJACENT CONSTRUCTION TO REMAIN.
H. LIMITS INDICATED FOR DEMOLITION OF EXISTING BRICK AND CMU MASONRY ARE APPROXIMATE. REMOVE MASONRY UNITS TO NEAREST MORTAR JOINTS TO PERMIT "TOOTHING IN" OF NEW MASONRY TO EXISTING COURSING, UNLESS NOTED OTHERWISE. REFER TO MECHANICAL DRAWINGS FOR REMOVAL OF THRU-WALL MECHANICAL GRILLES, REGISTERS, AND DUCTWORK.
I. ITEMS IDENTIFIED TO BE SALVAGED ("REMOVE AND DELIVER TO OWNER SHALL BE CAREFULLY REMOVED AND DELIVERED TO A STORAGE AREA DESIGNATED BY THE OWNER FOR THIS PURPOSE. ITEMS OWNER CHOOSES TO RETAIN SHALL BE RELOCATED FROM THE STORAGE AREA BY OWNER (NIC). ALL OTHER ITEMS SHALL BE SUBSEQUENTLY REMOVED AND
DISPOSED OF BY CONTRACTOR WHEN AUTHORIZED BY OWNER.
J. EXISTING LOOSE FURNITURE, EQUIPMENT, SUPPLIES, AND PERSONAL BELONGINGS LOCATED IN SPACES TO BE
RENOVATED SHALL BE REMOVED AND RELOCATED BY OWNER (NIC)
K. COORDINATE DEMOLITION WORK WITH NEW WORK NOTES TO ENSURE PROPER REMOVAL OF ITEMS.
L. PREPARE FLOOR FOR NEW FINISHES SCHEDULED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION FOR
FINISH SUBSTRATE. FILL VOIDS AND CRACKS IN CONCRETE TO PROVIDE SMOOTH FINISH.
M. PREPARE WALLS FOR NEW FINISHES SCHEDULED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS FOR FINISH SUBSTRATE. FILL VOIDS AND CRACKS AS REQUIRED. WHERE WALL MOUNTED ITEMS ARE REMOVED TAKE
SPECIAL CARE TO REMOVE PAINT BUILD-UP IN ORDER TO PROVIDE A SMOOTH SURFACE.
N. REFERENCE SPECIFICATION SECTION 017419- CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL FOR DISPOSAL OF
REMOVED ITEMS.
O. REMOVE ALL EXIST ITEMS PENETRATING CONCRETE SLAB (I.E. CONDUITS, PIPING, ANCHOR BOLTS, ETC.) TO BELOW
FINISH FLOOR
P. ALL DEMOLITION WORK SHALL BE CARRIED OUT IN A MANNER TO PROTECT ALL ADJACENT SURFACES WHICH REMAIN IN PLACE, PARTICULARLY FINISH SURFACES WHICH WILL REMAIN EXPOSED IN THE COMPLETED WORK.
Q. EXISTING LOOSE FURNITURE, EQUIPMENT, SUPPLIES, AND PERSONAL BELONGINGS LOCATED IN…