SHOP STORES - T9074-BD-GIB-010-0300 Appendix B.doc
DOC document 73 KB Posted
- Attached to
- METAL PLATE
- Solicitation number
- SPMYM222Q2363
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2157-7900 - CERTIFIED MILL TEST REPORT (CMTR) CDRL DI-MISC-80678 REV 4-11-2022.doc | DOC document | |
| SPMYM222Q2363.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL ORDERING DATA
T9074-BD-GIB-010-0300
IDN: N4523A -2157-7900
ICN:
KO:
KOI:
Paragraph 6.2 (p. 61) Ordering Data T9074-BD-GIB-010/0300 Rev 2 A. NAVSEA T9074-BD-GIB-010/0300 REV 2 - BASE MATERIALS FOR CRITICAL APPLICATIONS: REQUIREMENTS FOR LOW ALLOY STEEL PLATE, FORGINGS, CASTINGS, SHAPES, BARS, AND HEADS OF HY-80/100/130 AND HSLA-80/100; dated 18 DEC 2012.
B. Grade required (see 1.2): HY-80 C. If required, the specific issue of individual documents referenced (see 2.2.1 and 2.3): N/A D. When first article testing is not required (see 3.1): REQUIRED E. If virgin material is required (see 3.2): N/A F. When a batch-type furnace working zone temperature survey shall be conducted with a typical, nominal, or simulated furnace load (see 3.5.3): YES G. Dimensions of non-standard tensile test specimens (see 4.5.2): N/A H. Any special packaging requirements (see 5.2): N/A Paragraph B.6.2 (p. 103) Ordering Data T9074-BD-GIB-010/0300 Rev 2, Appendix B A. APPENDIX B (16216) – STEEL PLATE, ALLOY, STRUCTURAL, HIGH YIELD STRENGTH (HY-80 AND HY-100); dated 18 DEC 2012.
B. Sizes and number of plates required: 1/2" X 96" X 20' Long C. Type and grade required (see B.1.2):
Type: FORMDROPDOWN Grade: FORMDROPDOWN
D. If plates are required to be composed of all virgin raw material (see B.3.1): N/A E. If minimum ultimate tensile strength is required, the minimum value must be specified (see B.3.3.1 and Table B-2): N/A F. When a simulated stress relief sample is required. If required, the number of thermal cycles, the heating and cooling rates, and the time at temperature must be specified (see B.3.5.2 and B.4.4.2.5): N/A G. When weld repair after final heat treatment is prohibited or shall be conducted in accordance with processing and inspection standards other than those specified (see B.3.6.1): N/A H. When alternate ultrasonic soundness inspection requirements apply (see B.3.6.2, B.3.7, B.3.7.1, and B.4.6.5.1): N/A I. If plates over ½-inch thick are not to be ultrasonically inspected and ultrasonically measured for decimal thickness (see B.3.7): N/A J. When Type I plates are to be ultrasonically inspected for soundness (see B.3.7):
K. The applicable fabrication document (see B.3.8): T9074-BD-GIB-010/0300 L. When ordered to thickness, weight, or gauge (see B.3.9.1): TABLE B-6 M. When tighter tolerances are desired (see B.3.9.2): N/A N. When descaling and coating are not required (see B.3.10): N/A O. Type of coating required (see B.3.10 and Appendix K): N/A P. When explosion bulge type testing is required (see B.3.12): N/A Q. When first article specimens shall be located in areas other than shown on Figure A-1 and Figure A-2 (see B.4.3): N/A R. When HY-80 and HY-100 are to be tested together (see B.4.3): N/A S. When HY-100 has passed first article testing, whether explosion testing of HY-80 bulge data is required (see B.6.4.1): N/A Additional Data requirements:
Prepared By:
Code:
File details come from the government source that posted it. Updated .