SELCO CABLE TRUCK SPECS. Yes No Template -.PDF
PDF 125 KB Posted
- Attached to
- Cable Bucket truck
- Solicitation number
- BD-23-1324-SELCO-SELCO-89416
- Issued by
- Worcester County, Massachusetts
About this file
This document is a request for a government contract opportunity for Shrewsbury Electric & Cable Operations (SELCO) to purchase a 40-foot telescopic articulating aerial device, or cable bucket truck, along with associated equipment and accessories. The contract requires compliance with a detailed specification including a 400-lb platform capacity, non-continuous 370-degree rotation, hydraulic leveling system, electric-style controls, and other features. The requested quantity is 1 unit, with additional options for accessories like lighting, electrical components, and a hybrid system. The contract requires the vendor to provide two operator and maintenance/parts manuals, a structural warranty, and other documentation.
The contract also specifies the chassis requirements, including a Ford F450 with dual rear wheels, 4x2 configuration, and 60-inch cab-to-axle length. Pricing terms include a one-year parts and labor warranty, with an optional two-year extended warranty. No specific funding source or budget amount is provided. The contract opportunity is located in the state of Massachusetts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Advertisement for CATV Truck Bid-2023.doc | DOC document | |
| Proposal Sheet.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Customer SHREWSBURY
ELECTRIC & CABLE OPERATIONS
(SELCO)
Address 100 MAPLE AVE.
SHREWSBURY, MA 01545
US
This device shall be to the manufacture's standard. It shall be equipped with the manufacture's equipment and accessories which are included as standard in the advertised and published literature for the unit. No such item of equipment or accessories shall be removed or omitted for the reason that it was not specified in the bid.
If it is necessary to bid alternate equipment or to take exceptions to the specifications as set forth, this must be so stated in your bid. For each item, please place a X in the appropriate space (Yes__ No__) to signify whether or not you are in complete compliance with the specification. Failure to follow the format or answer the specification may cause your bid to be disqualified. If you need extra space to describe your product, please attach extra sheets. When doing this, be sure your description references the appropriate question number.
General Specifications
Comply Item Description Units Qty Yes No
Unit
1. Aerial Device EA 1 ____ ____
2. 40 foot telescopic articulating aerial device with an end mounted, hydraulically leveled platform. Unit installation is behind the cab chassis built in accordance with standard specifications and to include the following features:
EA 1 ____ ____
A. Ground to bottom of platform height: 35.0 feet ____ ____ B. Working height: 40.0 feet ____ ____ C. Maximum reach to edge of platform: 26.5 feet (at 12 foot platform height) ____ ____ D. Telescopic boom extension: 10 feet ____ ____ E. Noncontinuous rotation: 370 degrees ____ ____ F. Non-Insulating Aerial Device ____ ____ G. Platform Capacity: 400 lbs. ____ ____ H. Articulating Arm: Articulation is from 0 to 90 degrees. ____ ____ I. Compensation System: By raising or lowering the articulating arm only, the telescopic boom maintains its relative angle in relation to the ground.
The work position is achieved through a single function operation.
J. Telescoping upper boom: Articulation is from -25 to 78 degrees. ____ ____ K. Hydraulic Leveling: Platform automatically maintains level during boom articulation through a hydraulic leveling system that requires no major preventive maintenance. Hydraulic leveling permits storing of the platform in a horizontal position for road travel.
L. Controls: Electric style controls activate hydraulic valve for aerial device operation.
M. Hydraulic System: Open center system operating at 2.5 gpm and 2,200 psi ____ ____
Comply Item Description Units Qty Yes No
N. Unit is painted with a powder coat paint process which provides a finish-painted surface that is highly resistant to chipping, scratching, abrasion and corrosion.
O. Structural Warranty on all of the following applicable major components is to be warranted for so long as the initial purchaser owns the product:
Booms, boom articulation links, hydraulic cylinder structures, outrigger weldments, pedestals, subbases and turntables.
P. Manuals: Two (2) operator and Maintenance/Parts manuals ____ ____
3. Dual Strobe Beacons, Amber LED With Brush Guard EA 1 ____ ____
4. Poly Hydraulic Reservoir, Pedestal Mounted, 7 Gallon (Includes Sight Gauge) EA 1 ____ ____
5. Post mount pedestal EA 1 ____ ____
6. Single One (1) Man, Fiberglass Walk-In Platform; fixed position with door. 26 x 26 x 42 inches; includes safety strap and latch for door.
EA 1 ____ ____
7. Platform Cover, Soft With Elastic Retention And Lanyard Attachment, For Walk-In Platform
EA 1 ____ ____
8. 110 VAC Outlet At Platform EA 1 ____ ____
9. Two-Speed Electric controls at the platform include toggle switch controls for boom functions, an emergency stop switch, and a high/low speed selector that is integral with the master engage switch. Lower controls are on a pendent mounted box and include electric toggle switches and a 'push to operate' master engage switch. Lower controls are installed in a body compartment unless otherwise specified.
EA 1 ____ ____
10. Steel upper control cover EA 1 ____ ____
11. Manual lowering valve located at the boomtip. For use in emergency situations to allow the operator to lower the boom to the ground
EA 1 ____ ____
12. Engine Start/Stop With Secondary Stowage System EA 1 ____ ____
13. Powder coat unit white. EA 1 ____ ____
14. Additional Unit Option, 300 lb capacity lifting eye installed EA 1 ____ ____
15. ePTO, 2.5 GPM, Pedestal Mounted EA 1 ____ ____
Unit & Hydraulic Acc.
16. HVI-22 Hydraulic Oil (Standard) EA 9 ____ ____
17. Standard Pump for PTO EA 1 ____ ____
18. Hot Shift PTO (for Automatic Transmission) EA 1 ____ ____
19. Standard Altec PTO/Transmission Functionality for Non-Allison Automatic EA 1 ____ ____
Item Description Units Qty Yes No
Transmissions
20. Standard Parking Brake Machine interlock EA 1 ____ ____
Body
21. 108 Inch Universal Small Aerial Body for a 60 Inch CA Chassis with 38 Inch Long Side Access Tailshelf to Meet the Following Specifications:
EA 1 ____ ____
A. Basic body fabricated from A40 grade 100% zinc alloy coated steel ____ ____ B. All doors are full, double paneled, self-sealed with built-in drainage. ____ ____ C. Stainless steel hinge rods extend full length of door. ____ ____ D. Door hinges are zinc alloy material attached with rivets ____ ____ E. All doors contain stainless steel, flush mounted, paddle activated rotary style latches with two-stage locking, including keyed locks and adjustable strikers.
F. Heavy-gauge welded steel frame construction with smooth galvaneal floor. ____ ____ G. Possible contact edges are folded for safety. ____ ____ H. Door header drip rail at top for maximum weather protection. ____ ____ I. Neoprene or rolled fenders on wheel fender panels. ____ ____ J. Steel treated for improved primer bond and rust resistance. ____ ____ K. Automotive underseal applied to body. ____ ____ L. Automotive type non-porous door seals fastened to the door facing. ____ ____ M. 108 Inch Body Length ____ ____ N. 40 Inch Body Height (Standard) ____ ____ O. 94 Inch Body Width (Standard) ____ ____ P. 20 Inch Body Compartment Depth (Standard) ____ ____ Q. 8 Inch Body crossmembers (Standard) ____ ____ R. No Treadplate On Compartment Tops ____ ____ S. 6 Inch tall wooden tailboard installed at the rear of body cargo area ____ ____ T. Stainless Steel Rotary Paddle Latch With Lock (Standard) ____ ____ U. Master Body Locking System (Standard) ____ ____ V. One (1) Double-Capacity Chock Holder On Curbside Of Body ____ ____ W. Gas Shock Type Rigid Door Holders For Vertical Doors (Standard) ____ ____ X. Chains On Horizontal Doors ____ ____ Y. B-Line Channel Installed In Compartments ____ ____ Z. 1st Vertical Streetside (LH) - Two (2) Adjustable Shelves With
Removable Dividers On 4 Inch Centers
ZA. 1st Horizontal Streetside (LH) - One (1) Fixed Shelf With Removable Dividers On 8 Inch Centers
ZB. Rear Vertical Streetside (LH) - Six (6) Adjustable Locking Swivel Hooks ____ ____ ZC. 1st Vertical Curbside (RH) - Seven (7) Adjustable Locking Swivel Hooks, Louvered Panel Installed in Cargo Wall
ZD. 1st Vertical Curbside (RH) - One (1) Adjustable Shelf With Adjustable Dividers On 4 Inch Centers.
ZE. 1st Horizontal Curbside (RH) - One (1) Adjustable Shelf With Adjustable Dividers On 4 Inch Centers. One (1) Fixed Shelf On Bottom Of Compartment With Adjustable Dividers On 4 Inch Centers
Item Description Units Qty Yes No
ZF. Rear Vertical Curbside (RH) - Two (2) Adjustable Shelves With Removable Dividers On 4 Inch Centers
ZG. One (1) Small Bolt-On Grab Handle Installed At Rear Of Curbside Compartments
ZH. 38 Inch Tailshelf with Integrated Side Access Steps and Smooth Galvaneal Floor Installed at Rear of Body. Includes One (1) Square Grab Handle.
Body and Chassis Accessories
22. Set of Safety Chain Eye Bolts EA 1 ____ ____
23. ICC Underride Protection EA 1 ____ ____
24. Receiver Hitch, 2, Class 4, Incorporated Into Frame Extension EA 1 ____ ____
25. Rear Torsion Bar EA 1 ____ ____
26. No Counterweight Required EA 1 ____ ____
27. Rubber Belted Step, Mounted Beneath Side Access Steps (Installed to Extend Approx. 2 Outward)
EA 1 ____ ____
28. Ford OEM Aluminum Step Bars, Streetside and Curbside Installation, (Black) EA 1 ____ ____
29. Boom Rest "A" Configuration - Allows Approx. 18 inches on Streetside of Tailshelf Platform and Approx. 6 inches off the Tailshelf, Raise boom rest enough for platform to be able to stow in the underneath position without interference with retaining rail. Keep the platform as close to the SS as possible
EA 1 ____ ____
30. Steel Boom Saddle Support, Standard EA 1 ____ ____
31. Polyethylene Boom Saddle Support, Standard EA 1 ____ ____
32. Cover Plate For Cargo Area Boom Rest EA 1 ____ ____
33. Wheel Chocks Option 1, DICA wheel chocks UC1400-6 QTY 10 shipped loose Altec PN 066001021
EA 1 ____ ____
34. Mud Flaps with Altec Logo (Pair) EA 1 ____ ____
35. Rock Guards, Lexan EA 1 ____ ____
36. Lower Control Holder, Locate in the hotstick shelf at the rear door.
-Make the bracket in such a way that it has as minimal interference as possible getting the hotsticks out.
-mount bracket so that the lower control is on it's back
EA 1 ____ ____
37. Post Style Cone Holder (Holds up to four 15 x 15 large cones), Mounted on streetside of tailshelf, painted bright yellow
EA 1 ____ ____
38. PVC Canister Kit, 6 DIA Pipe 94 L with Aluminum Cap Door and Mounting U- EA 1 ____ ____
Item Description Units Qty Yes No
Bolts, mounted on the cs cargo
39. Inverter storage inside of body compartment with guard and provisions for remote GFCI receptacle, CS 1st vertical
EA 1 ____ ____
40. Battery Storage In Remote Steel Enclosure, Located Outside Of Body Compartments , Cargo Area CS and as forward as possible
EA 1 ____ ____
41. Ladder Storage Option 1, Prime design Ladder rack -installed on CS
EA 1 ____ ____
42. 5 LB Fire Extinguisher with Light Duty Bracket Installed Per DEPS 042 (In Cab Or Inside Compartment Only) (Amerex #B402T), Ship Loose with two decals
EA 1 ____ ____
43. Safety Harness and 4.5 Ft Lanyard (Fits Medium to Xlarge), Includes Pouch and Placards, Single Harness
EA 1 ____ ____
44. Triangular Reflector Kit (Contains 3 Reflectors) EA 1 ____ ____
45. Slope Indicator Assembly for Machine without Outriggers EA 1 ____ ____
46. Vinyl Manual Pouch for Storage of All Operator and Parts Manuals EA 1 ____ ____
47. Additional Body/Chassis Accessory, Remove SS horizontal shelf EA 1 ____ ____
Electrical Accessories
48. Adhesive Strip Lighting, LED, Installed Around Top And Sides Of Compartment Door Facings In Body (Installed At Final Assembly)
EA 6 ____ ____
49. Compartment Lights Wired To Dash Mounted Master Switch EA 1 ____ ____
50. Lights And Reflectors In Accordance With FMVSS 108 (Complete LED) EA 1 ____ ____
51. Strobe Light Option, ION Super LED V-series Strobe lights (IONSV1A P/N 9705-70186)
- (1) over wheel well SS
- (1) over wheel well CS
EA 1 ____ ____
52. Corner Strobe Systems Option, To be Federal Signal MPS300U-A Micro Pulse Ultra 3-LED Light head Amber
- Two (2) Surface Mounted Lights in Front Grille
- One (1) mounted rear of body curbside
- One (1) mounted rear of body streetside
- Altec Standard (2) Round Surface Mounted Lights at Rear
EA 1 ____ ____
53. Remote Spot Light, LED, Magnetic Mount, With Programmable Wireless EA 1 ____ ____
Item Description Units Qty Yes No
Remote (Go-Light #79014), Shipped loose
54. Remote Spot Light, LED, Permanent Mount, With Wireless Dash Mounted Controls And Programmable Wireless Remote (Go-Light #20074), Post mounted at the front of the body CS -Make sure to clear the ladder
EA 1 ____ ____
55. Single Tone Backup Alarm, Installed Between The Chassis Frame Rails At The Rear Of The Chassis. To Work In Conjunction With Chassis Reverse Drive System.
EA 1 ____ ____
56. Altec Backup Camera System, 7 Inch Color LCD Monitor, Heated Infrared Camera With Day/Night Sensor And Audio, Mount in place of rear view mirror
EA 1 ____ ____
A. 7 Inch Color LCD Monitor With LED Backlighting And Proximity Indicators
B. 2 Inputs With Independent Triggers ____ ____ C. Heated Infrared Camera With Day/Night Sensor And Audio ____ ____ D. Mirror/Normal View ____ ____ E. IP68 Rated ____ ____ F. Wide Viewing Angle (104 Degrees Horizontal x 78 Degrees Vertical) ____ ____ G. 20 Meter Cable Assembly ____ ____
57. Trailer Receptacle, 7-Way (Blade Type) Installed At Rear EA 1 ____ ____
58. Upfitter Switches, Ford (Supplied With Chassis) EA 1 ____ ____
59. Inverter Wired Battery Hot To Switch Mounted In Chassis Cab EA 1 ____ ____
60. Inverter/Charger, 3000 Watt, Pure Sine Wave, 120 VAC (Sensata #12NP30) EA 1 ____ ____
61. Auxiliary Batteries Option, Deep cycle aux battery in cargo area EA 1 ____ ____
62. Electrical Receptacle, 120 Volt, GFCI, Includes Weather-Resistant Enclosure , One (1) mounted on curbside rear vertical compartment above tailshelf
- Two (2) mounted behind seats in cab, wired to inverter
EA 3 ____ ____
63. Electrical Receptacle (120 Volt) Option, 240 outlet mounted inboard of the 120 on rear of curbside vertical compartment
EA 1 ____ ____
64. Power Distribution Module 10 is a Compact Self-Contained Electronic System that Provides a Standardized Interface with the Chassis Electrical System
EA 1 ____ ____
65. Install Remote Engine Start/Stop System In Final Assembly EA 1 ____ ____
66. Install Chassis (OEM) Supplied Backup Camera In Final Assembly EA 1 ____ ____
67. Install Secondary Stowage System In Final Assembly EA 1 ____ ____
68. Install ePTO in Final Assembly (JEMS DC) EA 1 ____ ____
Item Description Units Qty Yes No
69. PTO Indicator Light, Installed In Cab EA 1 ____ ____
Finishing Details
70. Front and Rear Frame Mounted and Under Body Mounted Components (With the Exception of Rust Resistant Components) Will Be Painted Black DEPS 005 DEPS 095 (Includes Non OEM Front Bumpers and Cabguards)
EA 1 ____ ____
71. Powder Coat Unit Altec White EA 1 ____ ____
72. Finish Paint Body Accessories Above Body Floor Altec White EA 1 ____ ____
73. Apply Non-Skid Coating (Black) to All Walking Surfaces DEPS 059 EA 1 ____ ____
74. Safety and Instructional Decals English EA 1 ____ ____
75. Vehicle Height Placard Installed In Cab DEPS 004 EA 1 ____ ____
76. HVI-22 Hydraulic Oil Placard EA 1 ____ ____
77. Stability Test Unit According to ANSI Requirements EA 1 ____ ____
78. Regional Build EA 1 ____ ____
79. Inbound Freight EA 1 ____ ____
80. As Built Electrical and Hydraulic Schematics to be Included In the Manual Pouch (Deps 024)
EA 1 ____ ____
81. Completed Test Forms To Be Included In The Manual Pouch:
-Stability Test Form -Dielectric Test Form (For Insulated Units)
EA 1 ____ ____
82. FA Installation EA 1 ____ ____
83. Hybrid System Installation EA 1 ____ ____
Hybrid
84. Hybrid System EA 1 ____ ____
A. 12 Volt DC Electric Motor coupled to Hydraulic Pump (ePTO). Installed on unit pedestal with steel guard to protect the electric motor.
B. Recharge Systems: A plug-in charge location is provided as standard on the streetside front of body (charging cord is provided). Batteries are recharged when plugged into a dedicated 30Amp 120VAC circuit. Drive cycle charge provides at least 50Amps of charge from the chassis alternator while driving. (NOTE: JEMS DC Drive requires a inverter/charger for plug-in charging.)
Item Description Units Qty Yes No
C. The JEMS control module (JCM) monitors and manages the JEMS DC Drive System. When the JEMS DC battery voltage drops below 10.5 Volts, the JCM attempts to automatically start the chassis to recharge the batteries. The batteries will continue to charge until the voltage reaches
13.5 Volts.
D. A cab-installed battery charge indicator provides JEMS DC Drive battery charge levels. The indicator will flash while the JCM automatically starts the chassis to recharge the batteries and continue flashing until the batteries reach 13.5 Volts.
E. On-Demand Operation: When the Master switch is turned ON, the JEMS DC Drive system is activated and the JCM manages the start/stop of the chassis engine. ePTO operation is available when the upper or lower control safety interlock has been satisfied.
F. Integral safety interlocks ensure that the following conditions must be met prior to unit operation: chassis in park, parking brake set, and a demand is created either through activation of the upper or lower control interlock.
G. Integral safety interlocks ensure that the vehicle auto-start will only be initiated when the hood is closed.
85. ePTO, 2.5 GPM, Mounted on Unit Pedestal EA 1 ____ ____
86. Hybrid System Control Module with Built-In Generator Select Mode EA 1 ____ ____
87. Two (2) Group 8D Sealed AGM Batteries EA 1 ____ ____
88. Hybrid System Battery Enclosure, Battery Storage Integrated into Tailshelf Assembly
EA 1 ____ ____
89. No Cab Comfort EA 1 ____ ____
90. Mobile / Jobsite Charging, Chassis Alternator, Ford Chassis EA 1 ____ ____
Chassis
91. Chassis EA 1 ____ ____
92. CHASSIS MODEL EA 1 ____ ____
93. 2025 Model Year EA 1 ____ ____
94. Ford F450 EA 1 ____ ____
95. Dual Rear Wheel EA 1 ____ ____
96. 4x2 EA 1 ____ ____
97. Chassis Cab EA 1 ____ ____
98. Regular Cab EA 1 ____ ____
99. Chassis Color - White EA 1 ____ ____
Item Description Units Qty Yes No
100. AM/FM Radio EA 1 ____ ____
101. Side Mirrors, Power Adjusting, Manual Folding, Manual Telescoping with Heated Glass
EA 1 ____ ____
102. Snow Plow Package EA 1 ____ ____
103. 12V DC Power Outlet EA 1 ____ ____
104. Air Conditioning EA 1 ____ ____
105. Cruise Control EA 1 ____ ____
106. Keyless Entry EA 1 ____ ____
107. Power Door Locks EA 1 ____ ____
108. Power Windows EA 1 ____ ____
109. 60 Clear CA (Round To Next Whole Number) EA 1 ____ ____
110. Chassis Wheelbase Length - 145 EA 1 ____ ____
111. GVWR 16,500 LBS EA 1 ____ ____
112. 7,000 LBS Front GAWR EA 1 ____ ____
113. 12,880 LBS Rear GAWR EA 1 ____ ____
114. Spring Suspension EA 1 ____ ____
115. Ford Gas 7.3L EA 1 ____ ____
116. Gas EA 1 ____ ____
117. Ford Torqshift 10-Speed Automatic Transmission (w/PTO Provision) EA 1 ____ ____
118. Ford 40 Gallon Fuel Tank (Rear) EA 1 ____ ____
119. Ford E/F250-550 Single Horizontal Right Side Exhaust EA 1 ____ ____
120. EPA Emissions EA 1 ____ ____
121. No Idle Engine Shut-Down Required EA 1 ____ ____
122. Hydraulic Brakes EA 1 ____ ____
123. Park Brake In Rear Wheels EA 1 ____ ____
124. Single Alternator (220 amp Minimum) EA 1 ____ ____
Item Description Units Qty Yes No
125. 63C - Aft Axle Frame Extension EA 1 ____ ____
Additional Pricing
126. Warranty: One (1) year parts warranty, one (1) year labor warranty, ninety (90) days warranty for travel charges, limited lifetime structural warranty
EA 1 ____ ____
Miscellaneous
127. Ext Warranty, TLME, 2 Year Total (1 Year Extended), Category 1 EA 1 ____ ____
USE OF OTHER NAMES AND REFERENCES:
Unless otherwise stated, the use of manufacturer's name and product numbers are for descriptive purposes and establishing general quality levels only. They are not intended to be restrictive. Bidders are required to state exactly what they intend to furnish, otherwise, it is fully understood that they shall furnish all items stated.
BROCHURES AND LITERATURE:
Your proposal must be accompanied by descriptive literature (marked), indicating the exact items to be furnished.
The term "as specified" will not be acceptable.
File details come from the government source that posted it. Updated .