Section_J_-_RTP_NC_CUP_05FEB2024.pdf
PDF 4 MB Posted
- Attached to
- Central Utility Plant (CUP) O&M services Federal contract opportunity
- Solicitation number
- 75N99023R00052
About this file
This document provides an overview of the Central Utility Plant (CUP) Operation and Maintenance services contract opportunity. The contractor will be responsible for the 24-hour operation and maintenance of all utility production equipment located in the CUP building, and distribution of utilities to various agency buildings on the National Institutes of Health RTP Campus. The utilities include high temperature hot water generators, water chillers, air compressors, electrical distribution equipment, diesel emergency generators, and associated pumps and equipment. The contractor will also maintain incinerators, cooling towers, air handling units, and distribution piping and ductwork. The solicitation is issued by the Department of Health and Human Services National Institutes of Health Construction.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_75N99023R00052.pdf | ||
| J14_-_NIEHS_Wastewater_Permit_2021.pdf | ||
| J15_-_NIEHS-EPA_Air_Permit_04226R37.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NIEHS CAMPUS SOLICITATION 75N99023R00052
RTP, NC Central Utility Plant (CUP) RFP
SECTION J –ATTACHMENTS
LIST OF ATTACHMENTS
Attachment Title J-1 Description of Existing CUP Facilities
J-2 Electrical Distribution Model
J-3 HTHW & CHW Routing Plan
J-4 Natural Gas Routing Plan
J-5 Sanitary Sewer Model
J-6 Storm Sewer Model
J-7 Domestic Cold-Water Model
J-8 Valve Pits and Manholes (NIEHS Facilities Only)
J-9 Valve Pits and Manholes (EPA Facilities Only)
J-10 NIEHS Campus Emergency Generators and Associated Equipment
J-11 Vivarium Environmental Parameters
J-12 NIEHS Health and Safety Branch – Procedures for Preforming Maintenance on Laboratory Hoods
J-13 Outgoing Contractor’s Phase Out Plan
J-14 Durham County Wastewater Permit No. DCL-007
J-15 NCDENR Air Permit No. 04226R37
ATTACHMENT J-1 – DESCRIPTION OF CUP EXISTING FACILITIES
This Appendix provides the Contractor with an overview of the existing facilities at the NIEHS Campus site in which the Contractor shall have responsibilities under this contract. The overview provides only a general description of the functions, major systems in the buildings, and major and special equipment.
1. CENTRAL UTILITY PLANT
BUILDING 105
SQUARE FOOTAGE: 36,800
NO. FLOORS: 2
Description of Functions in Facility Building 105 is the Central Utility Plant (CUP), the central heating and cooling plant for NIEHS Campus and EPA Campus. The building contains the high temperature hot water generating plants, a small laboratory, chilled water plants, electrical switchgear rooms, control rooms, offices, training/conference room, and shower/restroom facilities.
The high temperature hot water generating plant contains four (4) 40 MBTUH high temperature hot water (HTHW) generators, generating HTHW at 400 degrees F at 350 psig; primary and secondary HTHW system variable speed pumping equipment; expansion and storage tanks for HTHW and chilled water systems; and compressed air systems for atomization air for oil firing of generators, soot blowing and control air for instrumentation and chiller control equipment in the chilled water plant.
The chilled water plant contains five (5) 3,500 ton water chillers, condenser water pumps, primary and secondary variable speed chilled water pumps. Cooling towers are located adjacent to the CUP building.
Building 105 contains the various user interface hardware and software applications that provide the means of manipulating utility and facility control systems.
The control room P120 contains the central control and monitoring equipment to operate and monitor all CUP equipment. The current control system is ABB infi90.
Critical Environmental Conditions: None Mechanical Systems As stated above, the HTHW generators each have a generating capacity of 40 MBTUH of HTHW at 400 degrees F and 350 psig.
The generators can fire natural gas (primary fuel), No 2 fuel oil secondary. There are two 120,000 gallon aboveground fuel oil storage tanks located adjacent to the CUP. The oil is transferred from the aboveground tanks to pumps within the CUP which increase the pressure and pumps the oil to the burners on the HTHW generators. Boiler controls are electronic.
The HTHW System was designed as a primary-secondary-tertiary system with the secondary system being the underground circulation loop distributing HTHW to the NIEHS Campus and the EPA Campus. The plant has the capability for multiple configurations including split-plant operation with two generators providing HTHW for the NIEHS Campus and two generators providing HTHW for the EPA.
The HTHW system is pressurized with a nitrogen cushion. Nitrogen is introduced into the HTHW expansion tanks and the make-up storage tanks from individual sources.
The central chilled water producing equipment consists of 3,500 ton electric motor driven centrifugal water chillers, cooling towers, primary and secondary chilled water pumps, condenser water pumps, expansion tanks, pump down units and controls.
The chilled water system also was designed as a primary-secondary-tertiary system and is pressurized with nitrogen in the make-up CHW expansion tanks. Like the HTHW plant the chilled water plant is capable of multiple configurations.
HVAC Systems The HTHW generating plant is heated with ceiling-hung unit heaters supplied with HTHW and AHU's supplied with low pressure steam. Ventilation is drawn into the plant through wall and ceiling louvers and motorized dampers. Air is exhausted through roof-mounted exhaust fans.
The chilled water plant is also heated by HTHW unit heaters AND steam unit heaters, supplied with fresh air through wall louvers and air exhausted through roof-mounted exhaust fans.
The electrical switchgear room is heated with HTHW unit heaters and electric unit heaters. The room is ventilated through supply air ducts with duct-mounted registers, in line supply air fans and a roof-mounted air intake penthouse and wall louvers. Air is exhausted through roof-mounted exhaust fans.
An air handling unit with a HTHW heating coil and chilled water coil provides heating and cooling to the office and conference areas, control room, shops and storage; and shower and locker areas. A wall-mounted air conditioner supplies supplemental cooling in the Central Automated Monitoring System control room.
Plumbing A domestic hot water heater provides hot water to fixtures. Re-circulating hot water pumps and piping keeps water at desired temperatures in the system In addition to the toilets and shower facilities, there are counter top-mounted sinks in several areas, drinking fountains, and miscellaneous.
Fire Protection The entire building is protected with a wet pipe sprinkler system. A dry pipe sprinkler system is located under the covered loading dock between Building 105 and 106.
Electrical Systems The plant's electrical distribution system is supplied by four 13.2 KV feeders. The 13.2 KV is reduced in voltage by transformers located in the building to a 4160 volt system which provides power to the chiller motors and a 480 volt system which serves the remaining loads in the building. Transformers further reduce the 480 volts down to 208 and 120 volts as needed.
Emergency Power Systems A diesel emergency generator, rated 1100 KW, located outside the electrical switchgear room, provides emergency power to operate one HTHW generator and its associated equipment, primary and secondary pumps, control systems, emergency lighting, and other miscellaneous equipment.
Fire Alarm System For Buildings 105, 106, and 107, the office areas, electrical switchgear room, and chilled water plant have smoke detectors and manual pull stations with both horns and visual signals, all tied into a fire alarm control panel. There are manual pull stations with horns and visual signals in the HTHW plant. The fire alarm system is monitored by the Simplex Fire Alarm System located in the Building 101 Security Office.
Major Equipment:
• High temperature hot water generators & related equipment
• Water chillers and related equipment
• Air compressors and related equipment
• Main electrical distribution switchgear, panel boards, and motor control centers
• Diesel emergency generators
Special equipment: None Special maintenance attention:
• HTHW generators
• Water chillers
• Cooling towers
• Primary and Secondary pumps
• Air compressors
• Emergency generators
Critical Systems:
• HTHW generators
• Water chillers
• Cooling towers
• Primary and Secondary pumps
• Air compressors
• Emergency generators
2. INCINERATOR PLANT
BUILDING 106
SQUARE FOOTAGE: 13,510 feet
NO. FLOORS: 2
Description of Functions in Facility The Incineration Plant, NIEHS Building 106, is used for the incineration of soiled animal bedding, animal carcasses, non-hazardous laboratory waste (paper and plastic), chemical waste, biohazard/medical waste (e.g., waste from health units) and radioactive waste. Other activities performed at the Incineration Plant include waste receiving, handling, and short term storage incidental to incineration. The Incineration Plant is equipped with all the required safety and environmental features for this type of facility, including emergency showers, eye washes, spill containment dikes, exhaust fans, and refrigerated storage areas. The Incineration Plant has been modified to accommodate joint NIEHS and EPA needs for incineration and waste management.
These modifications included upgrading pollution control devices thereby allowing the NIEHS/EPA to meet more stringent air emission regulations.
The NIEHS Incineration Plant operations, air emission source(s) and air cleaning devices(s) for the discharge of the associated air contaminants into the atmosphere are permitted by the North Carolina Department of Environment and Natural Resources, Division of Air Quality (AIR PERMIT NO. 4226R36) in accordance with the provisions of Article 21B of Chapter 143, General statutes of North Carolina (NCGS) as amended, and other applicable Laws, Rules and Regulations. The NIEHS is considered to be in fee class: Synthetic Minor, at Site Number:
05/32/00158 on the permit. The air permit lists the following equipment in the Incineration Plant:
• One natural gas-fired incinerator (1,000 pounds per hour (maximum), type 0, 1, 2, 3, 4, and 5 wastes, with four 1.00 million Btu per hour (maximum) primary burners and a 5.0 million Btu per hour (maximum) secondary burner [ID No. ES-106-6] with one spray tower (204 gallons per minute injection rate, ID No. CD-106-1) and one wet scrubber (17 gallon per minute minimum injection rate, ID No. CD Page 2 106-2)
• Two natural gas-fired incinerator, 350 pounds per hour (maximum), type 0, 1, 2, 3, 4, and 5 wastes, with four 0.35 million Btu per hour (maximum) primary burners and a 1.5 million Btu per hour (maximum) secondary burner [ID No. ES-106-3 and ES-106-6].
Critical Environmental Conditions:
• Walk-in Environmental rooms
• Incinerators and emissions equipment Systems Monitored by Central Control:
• Fire protection system and security Mechanical Systems There is a pathological waste incinerator. The incinerator is fired with natural gas, rated 1,000 pounds per hour of type IV waste. The incinerator has electric/electronic controls, a hydraulic ram loader, and a wet quench ash removal system. There is a wet scrubber emission system with a cooling tower to cool emissions before entering the scrubber.
A monorail system installed above the incinerator is used to transfer the animal waste feed and bedding containers to a door on the hydraulic ram loader for feeding this waste into the incinerator. The monorail is also used to lift and transport the ash containers to a waste container for hauling to disposal site.
There are pathological incinerators, gas fired, rated 350 pounds per hour each when burning type IV waste. These incinerators have a hydraulic box loading system. One of the incinerators is equipped to burn liquid waste chemicals and solvents generated in the laboratories. A storage tank and transfer pump is utilized to mix the liquid waste chemicals and fuel oil and for pumping the mixture to the burner on the incinerator.
There is a cart wash to clean the pathological waste transport carts. Steam is provided by a high temperature hot water to steam generator. Steam is also supplied to a heating coil in the domestic hot water heater. Condensation is returned to the generator by a boiler feed unit.
HVAC Systems A hot water heating system consisting of a high temperature hot water to heating hot water convertor, pumps, unit heaters, and door heaters supply heat for the building except the office.
Ventilation air for the building is provided by heating and ventilating units also supplied from the hot water heating system. The rooms are exhausted by roof-mounted exhaust fans. The toilet and shower rooms are exhausted by separate exhaust fans.
The offices are heated and air conditioned by a through the wall air conditioner with electric heat.
Plumbing There is a toilet, locker & shower room. Hot water is provided by a natural gas tankless hot water heater. Domestic and soft water is supplied from Building 105.
Fire Protection The general purpose pathological incinerator area is protected with sprinklers. There are fire hose racks in the other areas of the building.
Electrical Systems Electrical service for Building 106 is supplied from Building 105 to a 480/277 volt, 3 phase, 4-wire, motor control center with 400 amp mains. The motor control center provides power to the mechanical equipment and also serves a sub-motor control center and a 120/208 volt lighting panel.
Fire Alarm System Water flow switches sense water flow and heat. Detectors in the ceiling sense temperature for the fire protection system and actuate sound and visual alarm systems. The system is tied into a fire alarm panel which is monitored by the Simplex Fire Alarm System.
Major Equipment:
• One General-purpose pathological incinerator, 1000 pounds per hour, with controls, emission equipment, and monitoring equipment
• Two Pathological and radioactive waste incinerators, 350 pounds per hour each, with controls and monitoring equipment
• Monorail crane system with remote control
• Hot water heaters and steam boiler with accessory equipment
• Cart washer/sterilizer.
• Ash containers and vacuum cleaning systems.
• Refuse containers.
• Two Trucks, dual wheel, with hydraulic operated lift gate for hauling bagged refuse.
• Special hoppers for collection of soiled animal feed and bedding
• Skid steer loader for handling refuse.
• Electrical power distribution, outdoor lighting, alarm and control systems.
Special equipment: None Special maintenance attention:
• Incinerators and emissions and monitoring equipment Critical Systems: None Radioactive Waste Radioactive waste is defined as laboratory waste product that contains Nuclear Regulatory Commission (NRC) licensed material as defined by 10 CFR 20.1003 or contains accelerator-produced radioactive material. The NIEHS and the EPA are required to abide by their respective NRC material licenses regarding the radioisotope and activity limits for incineration. Any radioactive waste that contains RCRA regulated material is classified as a "mixed waste".
Incineration of mixed waste is prohibited at the Building 106 facilities.
Medical Waste Medical waste is defined as any waste generated in the diagnosis, treatment, or immunization of human beings or animals, in research pertaining thereto, or in the production or testing of biologicals that is listed below [40 CFR 60.51c]:
• Cultures and stocks of infectious agents and associated biologicals
• Human pathological waste
• Human blood and blood products
• Used sharps
• Animal waste
• Isolation wastes
• Unused sharps
3. ELECTRICAL SUBSTATION
BUILDING 107
SQUARE FOOTAGE: 5,560
NO. FLOORS: 2
Description of Functions in Facility Building 107, the Electrical Substation Building, contains main site electrical switchgear and is supplied from the connecting substation served by Duke Power Company with two 110,000-volt incoming services.
Systems Monitored by Central Control:
• Fire protection system and security Critical Environmental Condition: None HVAC Systems
• Ceiling-hung electric heat units
• Ceiling hung DX HVAC unit
• Roof exhaust fans
Plumbing Sump Pumps located in the basement serving both building 107 sumps and the electrical manholes immediately outside of the building.
Electrical Systems Electrical service for Building 107 is supplied from a 13,800-volt transformer to a 120/208 volt, 3 phase, 4 wire, motor control center with 400 amp main. The motor control center provides power to the mechanical equipment and also serves a step up transformer 120/208 volt to 480 volt for manhole sump pumps.
Government electric distribution is accomplished through switchgear to 13,800-volt feeders to the NIEHS Campus and the EPA Campus.
Emergency Power:
Battery backup for substation control power (electrical safeties) Fire Alarm System Manual pull stations and smoke detectors in the ceiling sense and actuate sound and visual alarm systems. The system is tied into a fire alarm panel which is monitored by the Simplex Fire Alarm System.
Major equipment: Electrical Switchgear Special Equipment: None Special Maintenance Attention: Electrical Switchgear Critical Systems: Electrical Switchgear
ATTACHMENT J-2 – ELECTRICAL DISTRIBUTION MODEL
ATTACHMENT J-3 – HTHW & CHW ROUTING PLAN
ATTACHMENT J-4 – NATURAL GAS ROUTING PLAN
ATTACHMENT J-5 – SANITARY SEWER MODEL
ATTACHMENT J-6 – STORM SEWER MODEL
ATTACHMENT J-7 – DOMESTIC COLD WATER MODEL
ATTACHMENT J-8 – NIEHS VALVE PITS AND MANHOLE LOCATIONS
ATTACHMENT J-9 – CUP EQUIPMENT LIST
CUP EQUIPMENT LIST
Fac# Building Asset Room Comments
N5316 101-NC 101-NC – B00\BKFLOW-136606 - N5316 B005 (136606) 3" WATTS 909 RPZ
N5317 101-NC 101-NC - B00\BKFLOW-136612 - N5317 B005 (136612) 3" WATTS 909 RPZ
N5318 101-NC 101-NC - B00\BKFLOW-172007 - N5318 B005 (172007) 4" WATTS 909 RPZ
N5319 101-NC 101-NC - B00\BKFLOW-172062 - N5319 B005 (172062) 4" WATTS 909 RPZ
N5321 101-NC 101-NC - B00\BKFLOW-1915397 - N5321 B005 BY-PASS FOR 6" WILKINS (1915397) 3/4" WILKINS 950XL
DCVA
N5322 101-NC 101-NC - B00\BKFLOW-1934687 - N5322 B005 BY-PASS FOR 6" WILKINS (1934687) 3/4" WILKINS 950XL
DCVA
N5312 101-NC 101-NC - B00\BKFLOW-245207 - N5312 B005 FIRE PROTECTION, (245207) 6" WATTS 909 RPZ N5313 101-NC 101-NC - B00\BKFLOW-245208 - N5313 B005 FIRE PROTECTION, (245208) 6" WATTS 909 RPZ
N5314 101-NC 101-NC - B00\BKFLOW-246065 - N5314 B005 (246065) 6" WATTS 709 DCVA
N5315 101-NC 101-NC - B00\BKFLOW-246082 - N5315 B005 (246082) 6" WATTS 709 DCVA
N5320 101-NC 101-NC - B00\BKFLOW-269653 - N5320 B005 HTHW COOLING, (269653) 1" WATTS 909 RPZ N5327 101-NC 101-NC - B00\BKFLOW-334357 - N5327 B005 OVER 60# STEAM GEN (334357) 1" WATTS 909 RPZ N5328 101-NC 101-NC - B00\BKFLOW-399939 - N5328 B005 OVER 60# STEAM GEN (399939) 1" WATTS 909 RPZ N5325 101-NC 101-NC - B00\BKFLOW-V00551 - N5325 B005 FIRE PROTECTION (V0551) 6" WILKINS 350DA DCDA N5326 101-NC 101-NC - B00\BKFLOW-V00560 - N5326 B005 FIRE PROTECTION (V00560) 6" WILKINS 350DA DCDA
N5332 101-NC 101-NC - BKFLOW-3354572 - N5332 GROUND FIRE PROTECTION, 3/4" WILKINS 975XLD RPZ S#3354572
N5331 101-NC 101-NC - BKFLOW-R03297 - N5331 GROUND FIRE PROTECTION, 8" WILKINS 475DA RPDA S#R03297
N5323 101-NC 101-NC - E00\BKFLOW-1966063 - N5323 E011 BY-PASS FOR 6" WILKINS (1966063) 3/4" WILKINS 950XL
DCVA
N5324 101-NC 101-NC - E00\BKFLOW-N18602 - N5324 E011 FIRE PROTECTION (N18602) 6" WILKINS 350DA DCVA N2746 101-NC 101-NC - F00\BKFLOW-03104 - N2746 F051 DOMESTIC COLD WATER, (03104) 3"WATTS 009 RPZ N2747 101-NC 101-NC - F00\BKFLOW-03115 - N2747 F051 DOMESTIC COLD WATER, (03115) 3" WATTS 009 RPZ N2748 101-NC 101-NC - F00\BKFLOW-03524 - N2748 F051 LAB COLD WATER, (03524) 3" WATTS 009 RPZ N5308 101-NC 101-NC - F00\BKFLOW-1676431 - N5308 F051 8" BYPASS WILKINS, (1676431) 3/4" WILKINS 975XL RPZ N5309 101-NC 101-NC - F00\BKFLOW-1712346 - N5309 F051 8" BYPASS WILKINS, (1712346) 3/4" WILKINS 975XL RPZ N2745 101-NC 101-NC - F00\BKFLOW-3019 - N2745 F051 LAB COLD WATER, (03091) 3" WATTS 009 RPZ
N5365 101-NC 101-NC - F00\BKFLOW-401999 - N5365 F051 REHEAT HOT WATER MAKE UP (401999) 3/4" WATTS
909 RPZ
Fac# Building Asset Room Comments
N5366 101-NC 101-NC - F00\BKFLOW-402000 - N5366 F051 PREHEAT HOT WATER MAKE UP (402000) 3/4" WATTS
909 RPZ
N5367 101-NC 101-NC - F00\BKFLOW-426636 - N5367 F051 REHEAT HOT WATER MAKE UP (426636) 3/4" WATTS 909
RPZ
N5368 101-NC 101-NC - F00\BKFLOW-427043 - N5368 F051 PREHEAT HOT WATER MAKE UP (427043) 3/4" WATTS
909 RPZ
N5310 101-NC 101-NC - F00\BKFLOW-M01889 - N5310 F051 FIRE PROTECTION, (M01889) 8" WILKINS 375DA RPDA N5311 101-NC 101-NC - F00\BKFLOW-M02388 - N5311 F051 FIRE PROTECTION, (M02388) 8" WILKINS 375DA RPDA
N5329 101-NC 101-NC - VAULT#6-BKFLOW-W32171 - N5329 VAULT #6 VAULT #6, FIRE PROTECTION (W32171) 4" WILKINS 550
DCVA
N5330 101-NC 101-NC - VAULT#6-BKFLOW-W32230 - N5330 VAULT #6 VAULT #6, FIRE PROTECTION (W32230) 4" WILKINS 550
DCVA
N5334 102-NC 102-NC - 102\BKFLOW-628163 - N5334 S115X CHILL WATER MAKE-UP (628163) 3/4" WATTS 909QT RPZ N5337 102-NC 102-NC - 102\BKFLOW-J06186 - N5337 VP8 FIRE PROTECTION (J06186) 4" WILKINS 350 DCVA N5338 102-NC 102-NC - 102\BKFLOW-J06194 - N5338 VP 8 FIRE PROTECTION (J06194) 4" WILKINS 350 DCVA N5335 102-NC 102-NC - 102\BKFLOW-W24498 - N5335 VP 7 VALVE PIT 7 (W24498) 6" WILKINS 550 DCVA N5336 102-NC 102-NC - 102BKFLOW-W24498 - N5336 VP 7 VALVE PIT 7 (W32238) 6" WILKINS 550 DCVA
N5339 105-NC 105-NC - CUP\BKFLOW-0005110945 - N5339 P118 PROCESS WATER, MAKE-UP-BY-PASS (005110945) 6"
FEBCO 860 RPZ
N5340 105-NC 105-NC - CUP\BKFLOW-0006161239 - N5340 P118 PROCESS WATER, MAKE-UP (0006161239) 6" FEBCO
860 RPZ
N5341 105-NC 105-NC - CUP\BKFLOW-270704 - N5341 P112 MAKE-UP REFRIG RECOVERY TANK (270704) 3/4
WATTS 909 RPZ
N5342 105-NC 105-NC - CUP\BKFLOW-334511 - N5342 P118 MAKE-UP TO HTHW (334511) 2" WATTS 909 RPZ
N5345 105-NC 105-NC - CUP\BKFLOW-48327 - N5345 RISER FIRE PROT BY-PASSFOR 6"DCVA (48327) 3/4 WATTS
007M1 DCVA
N5346 105-NC 105-NC - CUP\BKFLOW-I-11749 - N5346 RISER FIRE PROTECTION (I-11749) 6" AMES 3000SS DCVA N5343 105-NC 105-NC - CUP\BKFLOW-W32169 - N5343 VP 1 (W32169) 4" WILKINS 550 DCVA N5344 105-NC 105-NC - CUP\BKFLOW-W32229 - N5344 VP 1 (W32229) 4" WILKINS 550 DCVA N5347 106-NC 106-NC - 106\BKFLOW-Y2678 - N5347 I106 AHU IN RM I-106 (Y2678) 1" FEBCO 825YA RPZ N5348 108-NC 108-NC - HAZ-MAT\BKFLOW-2DM1249 - N5348 VP FIRE PROTECTION (2DM1249) 8" AMES 2000 DCVA
N5349 108-NC 108-NC - HAZ-MAT\BKFLOW-432716 - N5349 108 DOMESTIC CONTAINMENT(432716) 1" WILKINS 975XL
RPZ
N5350 108-NC 108-NC - HAZ-MAT\BKFLOW-460488 - N5350 108 DOMESTIC CONTAINMENT (460488) 2" WILKINS 975XL
RPZ
N5351 108-NC 108-NC - HAZ-MAT\BKFLOW-477904 - N5351 108 DOMESTIC CONTAINMENT (477904) 2" WILKINS 975XL
RPZ
N5352 109-NC 109-NC - CRU\BKFLOW-2749081 - N5352 FIRE PROTECTION BY-PASS (2749081) 3/4 WILKINS
975XL RPZ
N5353 109-NC 109-NC - CRU\BKFLOW-2787701 - N5353 FIRE PROTECTION BY-PASS (2787701) 3/4 WILKINS
975XL RPZ
N5354 109-NC 109-NC - CRU\BKFLOW-A04662 - N5354 166 MAKE UP HUMIDIFIER (A04662) 3/4" WATTS 009M3 RPZ
N5355 109-NC 109-NC - CRU\BKFLOW-A32833 - N5355 189 MAKE UP COLD WATER LAB (A32833) 1" WATTS 009M2
RPZ
N5356 109-NC 109-NC - CRU\BKFLOW-A36325 - N5356 131 MAKE UP HEAT BOILER (A36325) 1" WATTS 009M2 RPZ
N5357 109-NC 109-NC - CRU\BKFLOW-A40773 - N5357 189 MAKE UP HOT WATER LAB (A40773) 1" WATTS 009M2
RPZ
N5358 109-NC 109-NC - CRU\BKFLOW-A65109 - N5358 129 MAKE UP CHILLED WATER (A65109) 3/4" WATTS 009M3
RPZ
N5359 109-NC 109-NC - CRU\BKFLOW-A67580 - N5359 181 MAKE UP HUMIDIFIER (A67580) 3/4" WATTS 009M3 RPZ N5360 109-NC 109-NC - CRU\BKFLOW-A82703 - N5360 152 MAKE UP HUMIDIFIER (A82703) 3/4" WATTS 009M3 RPZ
N5361 109-NC 109-NC - CRU\BKFLOW-M04751 - N5361 DOMESTIC CONTAINMENT, INSULATED ENCLOSURE
(M04751) 3" WILKINS 375 RPZ
N5362 109-NC 109-NC - CRU\BKFLOW-M04752 - N5362 DOMESTIC CONTAINMENT, INSULATED ENCLOSURE
(M04752) 3" WILKINS 375 RPZ
N5363 109-NC 109-NC - CRU\BKFLOW-R01934 - N5363 FIRE PROTECTION (R01934) 6" WILKINS 475 RPDA N5364 109-NC 109-NC - CRU\BKFLOW-R01967 - N5364 FIRE PROTECTION (R01967) 6" WILKINS 475 RPDA N7591 101-NC 101-NC - ROOF-INSPECTION - N7591 ROOF ROOF INSPECTION OF ALL BUILDINGS
N7674 105-NC 105-NC - CUP\STRUCTURE - N7674 BLDG 105 BUILDING STURCTURE
N7949 106-NC 106-NC - 106\STRUCTURE - N7949 BLDG 106 BUILDING STURCTURE
N7992 107-NC 107-NC - 107\STRUCTURE - N7992 BLDG 107 BUILDING STURCTURE
N3603 101-NC 101-NC - E01\ACT-VLV01 - N3603 EI001 ACTUATOR, VALVE
N0749 105-NC 105-NC - CUP\5000477 - N0749 P117 ACTUATOR, VALVE
N0750 105-NC 105-NC - CUP\5000606 - N0750 P117 ACTUATOR, VALVE
N0752 105-NC 105-NC - CUP\5000615 - N0752 P117 ACTUATOR, VALVE
N0754 105-NC 105-NC - CUP\5000752 - N0754 P117 ACTUATOR, VALVE
N0306 105-NC 105-NC - CUP\ACT-DPR01 - N0306 P117 ACTUATOR, DAMPER
N0307 105-NC 105-NC - CUP\ACT-DPR02 - N0307 P117 ACTUATOR, DAMPER
N0304 105-NC 105-NC - CUP\ACT-DPR03 - N0304 P117 ACTUATOR, DAMPER
N0305 105-NC 105-NC - CUP\ACT-DPR04 - N0305 P117 ACTUATOR, DAMPER
N0308 105-NC 105-NC - CUP\ACT-VLV/5-477 - N0308 P117 ACTUATOR, FUEL OIL CONTROL VALVE
N0309 105-NC 105-NC - CUP\ACT-VLV/5-606 - N0309 P117 ACTUATOR, GAS CONTROL VALVE
N0310 105-NC 105-NC - CUP\ACT-VLV/5-615 - N0310 P117 ACTUATOR, NATURAL GAS INLET VALVE N0311 105-NC 105-NC - CUP\ACT-VLV/5-752 - N0311 P117 ACTUATOR, MAIN OIL (FUEL VALVE)
N1231 105-NC 105-NC - CUP\NP_AHU-1 - N1231 P116 NORTH PLANT AIR HANDLING UNIT, SEVEN (7) ZONE, 6510 CFM
N7821 105-NC 105-NC - CUP\NP_AHU-2 - N7821 P111 NORTH PLANT AIR HANDLING UNIT 2, 52 GPM CHW, 7500 CFM
N7822 105-NC 105-NC - CUP\NP_AHU-3 - N7822 P111 NORTH PLANT AIR HANDLING UNIT 3, 52 GPM CHW, 7500 CFM
N7845 105-NC 105-NC - CUP\SF-1 - N7845 P123 SUPPLY VENT FAN 1, 5HP, 20K CFM, 005003694 N7846 105-NC 105-NC - CUP\SF-2 - N7846 P123 SUPPLY VENT FAN 2, 5HP, 20K CFM, 005003695
N7848 105-NC 105-NC - CUP\SP_AHU-1 - N7848 P121 SOUTH PLANT AIR HANDLING UNIT #1, 12K CFM, SERVES BOILER PLANT, HEATING
N7849 105-NC 105-NC - CUP\SP_AHU-2 - N7849 P121 SOUTH PLANT AIR HANDLING UNIT #2, 12K CFM, SERVES BOILER PLANT, HEATING
N7850 105-NC 105-NC - CUP\SP_AHU-3 - N7850 P121 SOUTH PLANT AIR HANDLING UNIT #3, 12K CFM, SERVES BOILER PLANT, HEATING
N7851 105-NC 105-NC - CUP\SP_AHU-4 - N7851 P121 SOUTH PLANT AIR HANDLING UNIT #4, 12K CFM, SERVES BOILER PLANT, HEATING
N7852 105-NC 105-NC - CUP\SP_AHU-5 - N7852 P121 SOUTH PLANT AIR HANDLING UNIT #5, 2K CFM, SERVES
CHWL PUMP VFD, COOLING
N7853 105-NC 105-NC - CUP\SP_AHU-6 - N7853 P121 SOUTH PLANT AIR HANDLING UNIT #6, 2K CFM, SERVES
HTHWL PUMP VFD, COOLING
N7854 105-NC 105-NC - CUP\SP_AHU-7 - N7854 P119-MEZ SOUTH PLANT AIR HANDLING UNIT #7, 600 CFM, SERVES CONTROL ROOM, COOLING
N1229 106-NC 106-NC - H&V-1 - N1229 I106 HEATING &VENTALATION UNIT 1, 10000 CFM, 10HP, 480V
N1230 106-NC 106-NC - H&V-2 - N1230 I106 HEATING &VENTALATION UNIT 2, 15000 CFM, 15HP, 480V
N1233 106-NC 106-NC - H&V-3 - N1233 I101 HEATING &VENTALATION UNIT 3, 3000 CFM, 3HP, 480V
N1234 107-NC 107-NC - 701AHU-SZ-001 - N1234 107 AIR HANDLING UNIT
N0322 105-NC 105-NC - AIR_CPR-3 - N0322 P118-MEZ QUINCY AIR COMPRESSOR, DUEL COMPRESSOR, 5001012
N6238 105-NC 105-NC - AIR_CPR-4 - N6238 P121 COMBUSTION AIR COMPRESSOR #4, ATLAS COPCO
PACKAGE UNIT, 10 HP
N6239 105-NC 105-NC - AIR_CPR-5 - N6239 P121 COMBUSTION AIR COMPRESSOR #5, ATLAS COPCO
PACKAGE UNIT, 10 HP
N0321 105-NC 105-NC - AIR_CPR-6 - N0321 P117 COMPRESSOR ,B-2 & B-3 COMBUSTION AIR
N6241 105-NC 105-NC - CUP\AIR_CPR-1 - N6241 P121 AIR COMPRESSOR #1, INGERSOL-RAND PACKAGE
UNIT, 125 PSI, 40 HP
N6242 105-NC 105-NC - CUP\AIR_CPR-2 - N6242 P121 AIR COMPRESSOR #2, INGERSOL-RAND PACKAGE
UNIT, 125 PSI, 40 HP
N7616 105-NC 105-NC - CUP\AIR_REC-4 - N7616 P121 AIR RECIEVER #4, 200 PSI, SILVAN INDUSTRIAL INC, PART #: D24G120
N1375 104-NC 104-NC - WH\AHU-1-DX - N1375
AHU-1 AIR HANDLING UNIT, DX HEAT PUMP, SERVES
COMPUTER RM, TRANE M#TWE180B400EL S#6433- WF-
4HD
N8436 104-NC 104-NC - WH\AHU-LEIBERT1-DX - N8436 LEIBERT-1 AIR HANDLING UNIT, DX HEAT PUMP, SERVES COMPUTER RM, LEIBERT M#DH380AUAAEI S#
N8437 104-NC 104-NC - WH\AHU-LEIBERT2-DX - N8437 LEIBERT-2 AIR HANDLING UNIT, DX HEAT PUMP, SERVES COMPUTER RM, LEIBERT M#DH380AUAAEI S#
N8438 104-NC 104-NC - WH\AHU-LEIBERT3-DX - N8438 LEIBERT-3 AIR HANDLING UNIT, DX HEAT PUMP, SERVES COMPUTER RM, LEIBERT M#DH380AUAAEI S#
N8439 104-NC 104-NC - WH\AHU-LEIBERT4-DX - N8439 LEIBERT-4 AIR HANDLING UNIT, DX HEAT PUMP, SERVES COMPUTER RM, LEIBERT M#DH380AUAAEI S#
N0815 106-NC 106-NC - AC-1 - N0815 I105 AIR CONDITIONING UNIT, 450 CFM, 18K BTU/HR
COOLING, 17.05K BTU/HR HEATING
N0816 107-NC 107-NC - AIR_COND-1 - N0816 107 HEAT PUMP
N7610 105-NC 105-NC - AIR_DR-1 - N7610 P116 INGERSOLL RAND DRYSTAR AIR DRYER
N7611 105-NC 105-NC - AIR_DR-2 - N7611 P121 MEZ INGERSOLL RAND AIR DRYER, MODEL: DXR200RTE5, 80
PSI, 5 HP
N7612 105-NC 105-NC - AIR_DR-3 - N7612 P121 MEZ INGERSOLL RAND AIR DRYER, MODEL: DXR200RTE5, 80
PSI, 5 HP
N0323 106-NC 106-NC - AIR_DR-1 - N0323 I102 INGERSOLL RAND DRYSTAR AIR DRYER
N7618 105-NC 105-NC - ATS-2 - N7618 P111 AUTOMATIC TRANSFER SWITCH #2, 05001525
N7619 105-NC 105-NC - ATS-3 - N7619 P111 AUTOMATIC TRANSFER SWITCH #3, 05001524
N7621 105-NC 105-NC - ATS-5 - N7621 P111 AUTOMATIC TRANSFER SWITCH #5, 05001520
N7869 105-NC 105-NC - SSCP1_2A - N7869 P124 AUTOMATIC TRANSFER SWITCH #2 (ATS-2), 05003667 N7873 105-NC 105-NC - SSCP1_4A - N7873 P124 AUTOMATIC TRANSFER SWITCH #3 (ATS-3), 05003668 N7874 105-NC 105-NC - SSCP1_5A - N7874 P124 AUTOMATIC TRANSFER SWITCH #4 (ATS-4), 05003669
N0293 101-NC 101-NC - C00\BAT-CRG01 - N0293 C055 BATTERY CHARGER
N0292 101-NC 101-NC - C00\BAT-CRG02 - N0292 C055 BATTERY CHARGER
N0294 101-NC 101-NC - F01\BAT-CRG01 - N0294 FL:F1 BATTERY CHARGER
N0299 105-NC 105-NC - BATT_CHGR-1 - N0299 P111 BATTERY CHARGER 1, SERVES 13.8 KV SWITCHGEAR
CONTROL POWER, 05001987
N7622 105-NC 105-NC - BATT_CHGR-2 - N7622 P111 BATTERY CHARGER 2, SERVES EMERGENCY DIESEL
GENERATOR 1
N3704 105-NC 105-NC - BATT_CHGR-3 - N3704 P124 BATTERY CHARGER 3 WITH DC CTRL PANEL, 05003614 N7924 106-NC 106-NC - BATT_CHGR-1 - N7924 I101 FORK TRUCK BATT CHARGER, MAC 24V, 02001426
N0302 107-NC 107-NC - BATT_CHGR-1 - N0302 107 BATTERY CHARGER 1
N0303 108-NC 108-NC - HAZ-MAT\BAT-CRG01 - N0303 103 BATTERY CHARGER
N0297 105-NC 105-NC - BPU-P1 - N0297 P112 BATTERY POWER UNIT FOR LP-P1, 1200W, 277V, 05001487
N0295 105-NC 105-NC - BPU-P3 - N0295 P112 BATTERY POWER UNIT FOR LP-P2, 1200W, 277V, 05000640
N3708 105-NC 105-NC - BATT_STN-1 - N3708 P111 BATTERY STATION 1, SERVES 13.8 KV SWITCHGEAR
CONTROL POWER,
N3709 105-NC 105-NC - BATT_STN-2 - N3709 P111 BATTERY STATION 2, SERVES EMERGENCY DIESEL
GENERATOR 1
N3706 105-NC 105-NC - BATT_STN-3 - N3706 P124 BATTERY STATION 3, 10 BATTERIES, TYPE 3CC-7, 150
AMP/HR
N0359 108-NC 108-NC - HAZ-MAT\BOILER01-STM - N0359 MR BOILER, FIRE TUBE, STEAM
N3621 105-NC 105-NC - CP-RECT-1 - N3621 P111 CATHODIC PROTECTION RECTIFIER 1, 05002349 N7634 105-NC 105-NC - CP-RECT-3 - N7634 P121 CATHODIC PROTECTION RECTIFIER 3, FUEL OIL TANKS N0379 105-NC 105-NC - CHILLER-3 - N0379 P112 CHILLER #3, CARRIER 3500TON, R134A, 05003490
N0382 105-NC 105-NC - CHILLER-4 - N0382 P123 CHILLER #4, YORK OM3500 TITAN CHILLER, R134A, 05003568
N0383 105-NC 105-NC - CHILLER-5 - N0383 P123 CHILLER #5, YORK OM3500 TITAN CHILLER, R134A, 05003569
N0384 105-NC 105-NC - CHILLER-6 - N0384 P123 CHILLER #6, YORK OM3500 TITAN CHILLER, R134A, 05003570
N7633 105-NC 105-NC - CP-1 - N7633 P124 CSI CONTROL PANEL 1, WALL LOUVER CONTROL
PANEL FOR SOUTH PLANT
N7841 105-NC 105-NC - SCU-1 - N7841 P117 NORTH PLANT CONTROL PANEL #1, LANDIS & GYR, 05003179
N7842 105-NC 105-NC - SCU-2 - N7842 P117 NORTH PLANT CTRL PANEL #2, VFD HTHWL-1 AND
HTHWL-2, 05003178
N7843 105-NC 105-NC - SCU-3 - N7843 P117 NORTH PLANT CTRL PANEL #3, VFD CHWL-1 AND
CHWL-2, 05003177
N7844 105-NC 105-NC - SCU-4 - N7844 P117 NORTH PLANT CONTROL PANEL #4, LANDIS & GYR, 05003180
N7862 105-NC 105-NC - SP_FOS_CTRL_PNL - N7862 P121 SOUTH PLANT FUEL OIL SYSTEM CONTROL PANEL N3721 106-NC 106-NC - H&V_CTRL_PNL-1 - N3721 I106 H&V UNITS 1 AND 2 CONTROL PANEL N7951 106-NC 106-NC - H&V_CTRL_PNL-2 - N7951 I107 DAC UNITS 2 AND 3 HVAC CONTROL PANEL N7952 106-NC 106-NC - H&V_CTRL_PNL-3 - N7952 I101 H&V UNIT 3 CONTROL PANEL, 06000572 N7637 105-NC 105-NC - CRITICAL_GAUGES - N7637 BLDG 105 GAUGE CALIBRATION, CRITICAL N7808 105-NC 105-NC - NONCRITICAL_GAUGES - N7808 BLDG 105 GAUGE CALIBRATION, NONCRITICAL N7835 105-NC 105-NC - REFRIG_MNTR-2 - N7835 P112 SQN-8X GAS MONITOR FOR CHILLER #1 AND #2
N7836 105-NC 105-NC - REFRIG_MNTR-3 - N7836 P112 CHILLGUARD RT REFRIDGERANT MONITOR FOR
CHILLER #3
N7926 106-NC 106-NC - CRITICAL_GAUGES - N7926 BLDG 106 GAUGE CALIBRATION, CRITICAL N7973 106-NC 106-NC - NONCRITICAL_GAUGES - N7973 BLDG 106 GAUGE CALIBRATION, NONCRITICAL N7991 107-NC 107-NC - CRITICAL_GAUGES - N7991 BLDG 107 GAUGE CALIBRATION, CRITICAL N7993 107-NC 107-NC - NONCRITICAL_GAUGES - N7993 BLDG 107 GAUGE CALIBRATION, NONCRITICAL
N1171 105-NC 105-NC - CT1_SLI-N - N1171 CT1 LEVEL INDICATOR, CT1, NORTH, 5003354
N1172 105-NC 105-NC - CT1_SLI-S - N1172 CT1 LEVEL INDICATOR, CT1, SOUTH, 5003353
N1173 105-NC 105-NC - CT2_SLI-N - N1173 CT2 LEVEL INDICATOR, CT2, NORTH
N1174 105-NC 105-NC - CT2_SLI-S - N1174 CT2 LEVEL INDICATOR, CT2, SOUTH
N7638 105-NC 105-NC - CT1 - N7638 CT1 NORTH COOLING TOWER (NIEHS), 5003445
N6307 105-NC 105-NC - CT2 - N6307 CT2 SOUTH COOLING TOWER (EPA), 5003513
N7927 106-NC 106-NC - CT-3 - N7927 CT3 COOLING TOWER 3
N7855 105-NC 105-NC - SP_BRIDGECRANE - N7855 P123 SOUTH CHILLER PLANT MAINTENANCE BRIDGE
CRANE
N0277 101-NC 101-NC - 101\LIGH-EM01 - N0277 LIGHTS, EMERGENCY, BUILDING
N0280 102-NC 102-NC - 102\LIGH-EM02 - N0280 LIGHTS, EMERGENCY, BUILDING
N0282 103-NC 103-NC - CHEM-STG\LIGH-EM03 - N0282 LIGHTS, EMERGENCY, BUILDING
N0278 104-NC 104-NC - WH\LIGH-EM04 - N0278 LIGHTS, EMERGENCY, BUILDING
N0279 105-NC 105-NC - CUP\LIGH-EM05 - N0279 LIGHTS, EMERGENCY, BUILDING
N0281 106-NC 106-NC - 106\LIGH-EM06 - N0281 LIGHTS, EMERGENCY, BUILDING
N1170 108-NC 108-NC - HAZ-MAT\LIGH-EM01 - N1170 103 LIGHTS, EMERGENCY, BUILDING
N7650 105-NC 105-NC - CUP\EF-1 - N7650 ROOF P121 EHAUST FAN 1, 1.5 HP, 7K CFM
N7651 105-NC 105-NC - CUP\EF-10 - N7651 ROOF P124 EHAUST FAN 10, 5HP, 30000 CFM
N7652 105-NC 105-NC - CUP\EF-11 - N7652 ROOF P124 EHAUST FAN 11, 5HP, 30000 CFM
N7653 105-NC 105-NC - CUP\EF-12 - N7653 ROOF P124 EHAUST FAN 12, 5HP, 30000 CFM
N7654 105-NC 105-NC - CUP\EF-13 - N7654 ROOF P124 EHAUST FAN 13, 5HP, 30000 CFM
N7655 105-NC 105-NC - CUP\EF-14 - N7655 ROOF P124 EHAUST FAN 14, 5HP, 30000 CFM
N0314 105-NC 105-NC - CUP\EF-1A - N0314 ROOF P112 EHAUST FAN 1A, 2HP, 005002176
N0315 105-NC 105-NC - CUP\EF-1B - N0315 ROOF P112 EHAUST FAN 1B, 2HP, 005000638
N0316 105-NC 105-NC - CUP\EF-1C - N0316 ROOF P112 EHAUST FAN 1C, 2HP, 005002174
N0317 105-NC 105-NC - CUP\EF-1D - N0317 ROOF P112 EHAUST FAN 1D, 2HP, 005001104
N7656 105-NC 105-NC - CUP\EF-2 - N7656 ROOF P121 EHAUST FAN 2, 1.5 HP, 7K CFM
N7657 105-NC 105-NC - CUP\EF-2A - N7657 P117 EHAUST FAN 2A, 16.83 KCFM, 1.5HP, 05002179
N7658 105-NC 105-NC - CUP\EF-2B - N7658 P117 EHAUST FAN 2B, 16.83 KCFM, 1.5HP
N7659 105-NC 105-NC - CUP\EF-2C - N7659 P117 EHAUST FAN 2C, 16.83 KCFM, 1.5HP
N7660 105-NC 105-NC - CUP\EF-2D - N7660 P117 EHAUST FAN 2D, 16.83 KCFM, 1.5HP
N7661 105-NC 105-NC - CUP\EF-3 - N7661 ROOF P121 EHAUST FAN 3, 1.5 HP, 7K CFM
N3711 105-NC 105-NC - CUP\EF-4 - N3711 ROOF P111 EHAUST FAN 4, 2HP, 05001996
N7662 105-NC 105-NC - CUP\EF-4 - N7662 ROOF P121 EHAUST FAN 4, 1.5 HP, 7K CFM
N3712 105-NC 105-NC - CUP\EF-5 - N3712 ROOF P111 EHAUST FAN 5, 2HP, 05001997
N7663 105-NC 105-NC - CUP\EF-5 - N7663 ROOF P123 EHAUST FAN 5, 5HP, 30K CFM
N7664 105-NC 105-NC - CUP\EF-6 - N7664 ROOF P123 EHAUST FAN 6, 5HP, 30K CFM
N7665 105-NC 105-NC - CUP\EF-7 - N7665 ROOF P123 EHAUST FAN 7, 5HP, 30K CFM
N7666 105-NC 105-NC - CUP\EF-8 - N7666 ROOF P123 EHAUST FAN 8, 5HP, 30K CFM
N7667 105-NC 105-NC - CUP\EF-9 - N7667 ROOF P123 EHAUST FAN 9, 5HP, 30K CFM
N0775 106-NC 106-NC - EF-1 - N0775 I107 EHAUST FAN 1, 9150 CFM, 480 V, 1.5 HP
N0776 106-NC 106-NC - EF-2 - N0776 I107 EHAUST FAN 2, 15000 CFM, 480 V, 3HP
N7939 106-NC 106-NC - EF-3 - N7939 I101 EHAUST FAN 3, 3000 CFM, 480 V, 1 HP
N7940 106-NC 106-NC - EF-3A - N7940 I101 EHAUST FAN 3A, 4800 CFM, 480 V, 2HP
N7941 106-NC 106-NC - EF-4 - N7941 I102 EHAUST FAN 4, 1750 CFM, 120 V, 1/4 HP
N7942 106-NC 106-NC - EF-4A - N7942 I103 EHAUST FAN 4A, 80 CFM, 120 V, 1/40 HP
N7943 106-NC 106-NC - EF-4B - N7943 I103 EHAUST FAN 4A, 80 CFM, 120 V, 1/40 HP
N7944 106-NC 106-NC - EF-4C - N7944 I104 EHAUST FAN 4B, 680 CFM, 120 V, 1/8 HP
N7945 106-NC 106-NC - EF-5 - N7945 I106 EHAUST FAN 5
N7946 106-NC 106-NC - EF-5A - N7946 I106 EHAUST FAN 5A
N0800 107-NC 107-NC - EF-1 - N0800 ROOF FAN, EXHAUST
N0801 107-NC 107-NC - EF-2 - N0801 ROOF FAN, EXHAUST
N0802 107-NC 107-NC - EF-3 - N0802 ROOF FAN, EXHAUST
N0803 107-NC 107-NC - EF-4 - N0803 ROOF FAN, EXHAUST
N0804 107-NC 107-NC - EF-5 - N0804 ROOF FAN, EXHAUST
N6224 107-NC 107-NC - EF-6 - N6224 107 EXHAUST FAN
N6225 107-NC 107-NC - EF-7 - N6225 107 EXHAUST FAN
N3596 108-NC 108-NC - HAZ-MAT\EF-1 - N3596 ROOF EXHAUST FAN
N3597 108-NC 108-NC - HAZ-MAT\EF-2 - N3597 ROOF EXHAUST FAN
N3598 108-NC 108-NC - HAZ-MAT\EF-3 - N3598 ROOF EXHAUST FAN
N3599 108-NC 108-NC - HAZ-MAT\EF-4 - N3599 ROOF EXHAUST FAN
N3600 108-NC 108-NC - HAZ-MAT\EF-5 - N3600 ROOF EXHAUST FAN
N3601 108-NC 108-NC - HAZ-MAT\EF-6 - N3601 ROOF EXHAUST FAN
N3602 108-NC 108-NC - HAZ-MAT\EF-9 - N3602 ROOF EXHAUST FAN
N0744 105-NC 105-NC - CUP\EYE-WSH01 - N0744 P117 EYEWASH / SHOWER #3, 05000682
N7671 105-NC 105-NC - CUP\EYE-WSH02 - N7671 P112 EYEWASH #5, 05001110
N7672 105-NC 105-NC - CUP\EYE-WSH03 - N7672 P123 EYEWASH / SHOWER
N7673 105-NC 105-NC - CUP\EYE-WSH-RO04 - N7673 P112 EYEWASH/SHOWER AT RO UNIT
N0742 106-NC 106-NC - 106\EYE-WSH01 - N0742 I101 EYEWASH/SHOWER IN ROOM I-101
N0743 106-NC 106-NC - 106\EYE-WSH02 - N0743 I106 EYEWASH/SHOWER IN ROOM I-106
N7947 106-NC 106-NC - 106\EYE-WSH03 - N7947 I107 EYEWASH IN ROOM I-107
N7948 106-NC 106-NC - 106\EYE-WSH04 - N7948 I107 EYEWASH/SHOWER IN ROOM I-107-2
N0735 108-NC 108-NC - HAZ-MAT\EYE-WSH02 - N0735 115 EYEWASH
N7706 105-NC 105-NC - CUP\LOUVER-P117-1 - N7706 P117 VENT LOUVER BANK P117-1
N7707 105-NC 105-NC - CUP\LOUVER-P117-2 - N7707 P117 VENT LOUVER BANK P117-2
N7708 105-NC 105-NC - CUP\LOUVER-P117-3 - N7708 P117 VENT LOUVER BANK P117-3
N7709 105-NC 105-NC - CUP\LOUVER-P124-1 - N7709 P124 FILTERED LOUVER BANK P124-1
N7710 105-NC 105-NC - CUP\LOUVER-P124-2 - N7710 P124 FILTERED LOUVER BANK P124-2
N7711 105-NC 105-NC - CUP\LOUVER-P124-3 - N7711 P124 FILTERED LOUVER BANK P124-3
N7712 105-NC 105-NC - CUP\LOUVER-P124-4 - N7712 P124 FILTERED LOUVER BANK P124-4
N7713 105-NC 105-NC - CUP\LOUVER-P124-5 - N7713 P124 FILTERED LOUVER BANK P124-5
N7930 106-NC 106-NC - D-A - N7930 I102 MOTORIZED DAMPER W/ FILTERS, D-A, 54"x18"X20", 1300CFM
N7934 106-NC 106-NC - D-B - N7934 I101 MOTORIZED DAMPER W/ FILTERS, D-C, 72"x24"X20", 2400CFM
N7935 106-NC 106-NC - D-C - N7935 I101 MOTORIZED DAMPER W/ FILTERS, D-A, 72"x24"X20", 2400CFM, 0600646
N7936 106-NC 106-NC - D-D - N7936 I106 MOTORIZED DAMPER W/ FILTERS,
N7953 106-NC 106-NC - INCEN_DAMPER - N7953 I106 MOTORIZED DAMPER FOR LARGE INCINERATOR
N1370 105-NC 105-NC - CT1_FAN-A - N1370 CT1 FAN, CT1, CELL A, 5003351
N1369 105-NC 105-NC - CT1_FAN-B - N1369 CT1 FAN, CT1, CELL B, 5003350
N1368 105-NC 105-NC - CT1_FAN-C - N1368 CT1 FAN, CT1, CELL C, 5003349
N0642 105-NC 105-NC - CT2_FAN-A - N0642 CT2 FAN, CT2, CELL A, 5003514
N0643 105-NC 105-NC - CT2_FAN-B - N0643 CT2 FAN, CT2, CELL B, 5003515
N0644 105-NC 105-NC - CT2_FAN-C - N0644 CT2 FAN, CT2, CELL C, 5003516
N0645 105-NC 105-NC - CT2_FAN-D - N0645 CT2 FAN, CT2, CELL D, 5003517
N7931 106-NC 106-NC - DAC-1 - N7931 I101 DOOR AIR CURTAIN, 9000 CFM, 2.2 HP, 06000648
N7932 106-NC 106-NC - DAC-2 - N7932 I107 DOOR AIR CURTAIN, MODEL AH-56, 56,250 CFM, 30 HP, 480 V, 06001458
N7933 106-NC 106-NC - DAC-3 - N7933 I107 DOOR AIR CURTAIN, MODEL AH-56, 56,250 CFM, 30 HP, 480 V, 06000472
N7675 105-NC 105-NC - CUP\FCU-1 - N7675 P102 FAN COIL UNIT 1
N7698 105-NC 105-NC - CUP\ILF-1 - N7698 P116 IN-LINE FAN 1, RETURN FOR SP_AHU-1, 5010 CFM, 3
HP, 05001457
N0778 108-NC 108-NC - HAZ-MAT\FILTER01 - N0778 ROOF FILTER, BAG IN/BAG OUT
N0779 108-NC 108-NC - HAZ-MAT\FILTER02 - N0779 ROOF FILTER, BAG IN/BAG OUT
N0780 108-NC 108-NC - HAZ-MAT\FILTER03 - N0780 ROOF FILTER, BAG IN/BAG OUT
N0781 108-NC 108-NC - HAZ-MAT\FILTER04 - N0781 ROOF FILTER, BAG IN/BAG OUT
N0782 108-NC 108-NC - HAZ-MAT\FILTER05 - N0782 ROOF FILTER, BAG IN/BAG OUT
N0783 108-NC 108-NC - HAZ-MAT\FILTER06 - N0783 ROOF FILTER, BAG IN/BAG OUT
N0784 108-NC 108-NC - HAZ-MAT\FILTER07 - N0784 ROOF FILTER, BAG IN/BAG OUT
N0785 108-NC 108-NC - HAZ-MAT\FILTER08 - N0785 ROOF FILTER, BAG IN/BAG OUT
N0786 108-NC 108-NC - HAZ-MAT\FILTER09 - N0786 ROOF FILTER, BAG IN/BAG OUT
N0787 108-NC 108-NC - HAZ-MAT\FILTER10 - N0787 ROOF FILTER, BAG IN/BAG OUT
N0788 108-NC 108-NC - HAZ-MAT\FILTER11 - N0788 ROOF FILTER, BAG IN/BAG OUT
N0789 108-NC 108-NC - HAZ-MAT\FILTER12 - N0789 ROOF FILTER, BAG IN/BAG OUT
N0790 108-NC 108-NC - HAZ-MAT\FILTER13 - N0790 ROOF FILTER, BAG IN/BAG OUT
N0792 108-NC 108-NC - HAZ-MAT\FILTER14 - N0792 ROOF FILTER, BAG IN/BAG OUT
N0793 108-NC 108-NC - HAZ-MAT\FILTER15 - N0793 ROOF FILTER, BAG IN/BAG OUT
N0791 108-NC 108-NC - HAZ-MAT\FILTER16 - N0791 ROOF FILTER, BAG IN/BAG OUT
N0849 NC- General NC-General - R&G\5003698 - N0849 GROUND HYDRANT, FIRE N0850 NC- General NC-General - R&G\5003699 - N0850 GROUND HYDRANT, FIRE
N0851 NC- General NC-General - R&G\5003700 - N0851 GROUND HYDRANT, FIRE N0852 NC- General NC-General - R&G\5003701 - N0852 GROUND HYDRANT, FIRE N0853 NC- General NC-General - R&G\5003702 - N0853 GROUND HYDRANT, FIRE N0854 NC- General NC-General - R&G\5003703 - N0854 GROUND HYDRANT, FIRE N0855 NC- General NC-General - R&G\5003704 - N0855 GROUND HYDRANT, FIRE N0856 NC- General NC-General - R&G\5003705 - N0856 GROUND HYDRANT, FIRE N0857 NC- General NC-General - R&G\5003706 - N0857 GROUND HYDRANT, FIRE N0858 NC- General NC-General - R&G\5003707 - N0858 GROUND HYDRANT, FIRE N0859 NC- General NC-General - R&G\5003708 - N0859 GROUND HYDRANT, FIRE N0860 NC- General NC-General - R&G\5003709 - N0860 GROUND HYDRANT, FIRE N0861 NC- General NC-General - R&G\5003710 - N0861 GROUND HYDRANT, FIRE N0862 NC- General NC-General - R&G\5003711 - N0862 GROUND HYDRANT, FIRE N0863 NC- General NC-General - R&G\5003712 - N0863 GROUND HYDRANT, FIRE N0864 NC- General NC-General - R&G\5003713 - N0864 GROUND HYDRANT, FIRE N0865 NC- General NC-General - R&G\5003714 - N0865 GROUND HYDRANT, FIRE N0866 NC- General NC-General - R&G\5003715 - N0866 GROUND HYDRANT, FIRE N0867 NC- General NC-General - R&G\5003716 - N0867 GROUND HYDRANT, FIRE N0868 NC- General NC-General - R&G\5003717 - N0868 GROUND HYDRANT, FIRE N0869 NC- General NC-General - R&G\5003718 - N0869 GROUND HYDRANT, FIRE N0387 NC- General NC-General - R&G\FIR-HYD01 - N0387 GROUND HYDRANT, FIRE N0388 NC- General NC-General - R&G\FIR-HYD02 - N0388 GROUND HYDRANT, FIRE N0393 NC- General NC-General - R&G\FIR-HYD03 - N0393 GROUND HYDRANT, FIRE N0385 NC- General NC-General - R&G\FIR-HYD11 - N0385 GROUND HYDRANT, FIRE N0399 NC- General NC-General - R&G\FIR-HYD12 - N0399 GROUND HYDRANT, FIRE N0400 NC- General NC-General - R&G\FIR-HYD13 - N0400 GROUND HYDRANT, FIRE N0395 NC- General NC-General - R&G\FIR-HYD19 - N0395 GROUND HYDRANT, FIRE N0396 NC- General NC-General - R&G\FIR-HYD20 - N0396 GROUND HYDRANT, FIRE N0397 NC- General NC-General - R&G\FIR-HYD21 - N0397 GROUND HYDRANT, FIRE N0398 NC- General NC-General - R&G\FIR-HYD22 - N0398 GROUND HYDRANT, FIRE
N0389 NC- General NC-General - R&G\FIR-HYD24 - N0389 GROUND HYDRANT, FIRE N0390 NC- General NC-General - R&G\FIR-HYD25 - N0390 GROUND HYDRANT, FIRE N0392 NC- General NC-General - R&G\FIR-HYD26 - N0392 GROUND HYDRANT, FIRE N0394 NC- General NC-General - R&G\FIR-HYD27 - N0394 GROUND HYDRANT, FIRE N0401 NC- General NC-General - R&G\FIR-HYD28 - N0401 GROUND HYDRANT, FIRE N0402 NC- General NC-General - R&G\FIR-HYD29 - N0402 GROUND HYDRANT, FIRE
N7823 105-NC 105-NC - NP_FUEL_OIL_SYS - N7823 P117 NORTH PLANT FUEL OIL SYSTEM
N7831 105-NC 105-NC - PETROTAPE_UNIT - N7831 P121 PETROTAPE UNIT FOR FO STORAGE TANKS #1 AND #2
N7863 105-NC 105-NC - SP_FUEL_OIL_SYS - N7863 P124 SOUTH PLANT FUEL OIL SYSTEM
N0530 101-NC 101-NC - C00\EMR-GEN01 - N0530 C055 GENERATOR, EMERGENCY
N0690 101-NC 101-NC - C00\EMR-GEN02 - N0690 C055 ENGINE, DIESEL, EMERGENCY
N0691 101-NC 101-NC - C00\EMR-GEN03 - N0691 C055 ENGINE, DIESEL, EMERGENCY
N0531 101-NC 101-NC - C00\EMR-GEN04 - N0531 C055 GENERATOR, EMERGENCY
N0689 101-NC 101-NC - F01\EMR-GEN01 - N0689 GROUND ENGINE, DIESEL, EMERGENCY
N0284 101-NC 101-NC - F01\EMR-GEN02 - N0284 101 GENERATOR, EMERGENCY
N0283 105-NC 105-NC - EDG-1 - N0283 P110 EMERG. GENERATOR #1
N0687 105-NC 105-NC - EDG-2 - N0687 P110 EMERG. GENERATOR #2
N0290 108-NC 108-NC - HAZ-MAT\EMR-GEN01 - N0290 108 ENGINE, EMER. GENERATOR
N1547 105-NC 105-NC - HTHW_GEN-2 - N1547 P117 HTHW GENERATOR #2, INDECK IBW MODEL TJW-C-40
N1543 105-NC 105-NC - HTHW_GEN-3 - N1543 P117 HTHW GENERATOR #3, VOLCANO MODEL TJW-C-40, 5003245
N1544 105-NC 105-NC - HTHW_GEN-4 - N1544 P121 HTHW GENERATOR #4, VOLCANO MODEL TJW-C-40, 5003603
N1545 105-NC 105-NC - HTHW_GEN-5 - N1545 P121 HTHW GENERATOR #5, VOLCANO MODEL TJW-C-40, 5003604
N7847 105-NC 105-NC - SG-1 - N7847 P117 STEAM GENERATOR, DEAERATOR #1, SG-1
N6259 105-NC 105-NC - SG-2 - N6259 P121 STEAM GENERATOR, DEAERATOR #2, SG-2
N7929 106-NC 106-NC - CV-A - N7929 I106 HOT WATER CONVERTER, 9070MBH, 175 GPM HTHW, 630 GPM HHW
N7984 106-NC 106-NC - WTR_HTR-1 - N7984 I102 INSTANTANEOUS WATER HEATER, 199000 BTU/HR N7985 106-NC 106-NC - WTR_HTR-2 - N7985 I102 INSTANTANEOUS WATER HEATER, 199000 BTU/HR
N0353 106-NC 106-NC - HOIST_SYS - N0353 I107 BLDG 106 HOIST AND MONORAIL SYSTEM, 06000508
N7629 105-NC 105-NC - CH4-CAP - N7629 P124 750KVA CAPACITOR SERVING CHILLER #4
N7630 105-NC 105-NC - CH5-CAP - N7630 P124 750KVA CAPACITOR SERVING CHILLER #5
N7631 105-NC 105-NC - CH6-CAP - N7631 P124 750KVA CAPACITOR SERVING CHILLER #6
N7632 105-NC 105-NC - CHILLER3_MTR_STR - N7632 P112 CHILLER #3 MOTOR STARTER, GE, 4160V, 3000HP
N2715 105-NC 105-NC - USCP2A_1A - N2715 P124 USCP2A SUBSTATION MAIN BREAKER, 2000A, 4.16 KV, 05003629
N2723 105-NC 105-NC - USCP2A_1B - N2723 P124 USCP2B SUBSTATION MAIN BREAKER, 2000A, 4.16 KV, 05003630
N2716 105-NC 105-NC - USCP2A_1C - N2716 P124 USCP2A & USCP2B TIE BREAKER, 2000A, 4.16 KV, 05003628
N2717 105-NC 105-NC - USCP2A_2A - N2717 P124 CHILLER-4 MOTOR STARTER, 390 A, 4.16 KV N2724 105-NC 105-NC - USCP2A_2B - N2724 P124 CWP-5 MOTOR STARTER, 130 A, 4.16 KV, 05003623 N2718 105-NC 105-NC - USCP2A_3A - N2718 P124 CWP-4 MOTOR STARTER, 130 A, 4.16 KV, 05003626 N2725 105-NC 105-NC - USCP2A_3B - N2725 P124 CHILLER-5 MOTOR STARTER, 390 A, 4.16 KV, 05003620
N2719 105-NC 105-NC - USCP2A_4A - N2719 P124 CHILLER-4 CAPACITOR BANK BREAKER, 600 A, 4.16 KV, 05003627
N7898 105-NC 105-NC - USCP2A_4B - N7898 P124 CHILLER-5 CAPACITOR BANK BREAKER, 600 A, 4.16 KV, 05003625
N2720 105-NC 105-NC - USCP2A_5A - N2720 P124 CHILLER-6 MOTOR STARTER, 390 A, 4.16 KV, 05003621 N2721 105-NC 105-NC - USCP2A_6A - N2721 P124 CWP-6 MOTOR STARTER, 130 A, 4.16 KV, 05003622
N2722 105-NC 105-NC - USCP2A_7A - N2722 P124 CHILLER-6 CAPACITOR BANK BREAKER, 600 A, 4.16 KV, 05003624
N0325 106-NC 106-NC - INCEN-1 - N0325 I106 MAIN WASTE INCENERATOR #1
N0726 106-NC 106-NC - RAD_PATH_INCEN-1 - N0726 I101 RADIOLOGICAL & PATHALOGICAL WASTE
INCENERATOR #1
N0725 106-NC 106-NC - RAD_PATH_INCEN-2 - N0725 I101 RADIOLOGICAL & PATHALOGICAL WASTE
INCENERATOR #2
N1176 NC- General NC-General - R&G\CONT-LV001 - N1176 GROUND LEVEL CONTROL & ALARM N1175 NC- General NC-General - R&G\CONT-LV002 - N1175 GROUND LEVEL CONTROL & ALARM N1177 NC- General NC-General - R&G\CONT-LV003 - N1177 GROUND LEVEL CONTROL & ALARM N1178 NC- General NC-General - R&G\CONT-LV004 - N1178 GROUND LEVEL CONTROL & ALARM N1179 NC- General NC-General - R&G\CONT-LV005 - N1179 GROUND LEVEL CONTROL & ALARM
N1180 NC- General NC-General - R&G\CONT-LV006 - N1180 GROUND LEVEL CONTROL & ALARM WITH PUMP CONTROLLER N1181 NC- General NC-General - R&G\CONT-LV007 - N1181 GROUND LEVEL CONTROL & ALARM N7717 105-NC 105-NC - MCCNC1_1A - N7717 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003683 N7718 105-NC 105-NC - MCCNC1_1B - N7718 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003683 N7719 105-NC 105-NC - MCCNC1_1C - N7719 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003688 N7720 105-NC 105-NC - MCCNC1_1D - N7720 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003689 N7721 105-NC 105-NC - MCCNC1_1E - N7721 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003690 N7722 105-NC 105-NC - MCCNC1_2A - N7722 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003691 N7723 105-NC 105-NC - MCCNC1_2B - N7723 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT, 05003692
N7724 105-NC 105-NC - MCCNC1_2C - N7724 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7725 105-NC 105-NC - MCCNC1_2D - N7725 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7726 105-NC 105-NC - MCCNC1_2E - N7726 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7727 105-NC 105-NC - MCCNC1_2F - N7727 P123 MOTOR STARTER, FVNR, NEMA 2, 25AT
N7728 105-NC 105-NC - MCCNC1_3A - N7728 P123 MOTOR STARTER, FVNR, NEMA 2, 40AT
N7729 105-NC 105-NC - MCCNC1_3B - N7729 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7736 105-NC 105-NC - MCCNC1_4C - N7736 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7737 105-NC 105-NC - MCCNC1_4D - N7737 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7738 105-NC 105-NC - MCCNC1_4E - N7738 P123 MOTOR STARTER, FVNR, NEMA 1, 5AT
N7740 105-NC 105-NC - MCCNC1_5A - N7740 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7741 105-NC 105-NC - MCCNC1_5B - N7741 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7742 105-NC 105-NC - MCCNC2 - N7742 P123 MCC-NC2, 480V, 3-PH, 1000A MLO
N7743 105-NC 105-NC - MCCNC2_1A - N7743 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7744 105-NC 105-NC - MCCNC2_1B - N7744 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7745 105-NC 105-NC - MCCNC2_1C - N7745 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7746 105-NC 105-NC - MCCNC2_1D - N7746 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7747 105-NC 105-NC - MCCNC2_2A - N7747 P123 MOTOR STARTER, FVNR, NEMA 1, 5AT
N7748 105-NC 105-NC - MCCNC2_2B - N7748 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7749 105-NC 105-NC - MCCNC2_2C - N7749 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7750 105-NC 105-NC - MCCNC2_2D - N7750 P123 MOTOR STARTER, FVNR, NEMA 1, 10AT
N7751 105-NC 105-NC - MCCNC2_2E - N7751 P123 MOTOR STARTER, FVNR, NEMA 1, 5AT
N7752 105-NC 105-NC - MCCNC2_2F - N7752 P123 MOTOR STARTER, FVNR, NEMA 2, 40AT
N7753 105-NC 105-NC - MCCNC2_3A - N7753 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7754 105-NC 105-NC - MCCNC2_3B - N7754 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7755 105-NC 105-NC - MCCNC2_4A - N7755 P123 MOTOR STARTER, FVNR, NEMA 5, 400AT
N7756 105-NC 105-NC - MCCNC2_4B - N7756 P123 MOTOR STARTER, FVNR, NEMA 2, 40AT
N7764 105-NC 105-NC - MCCNC2_5D - N7764 P123 MOTOR STARTER, FVNR, NEMA 2, 25AT
N7779 105-NC 105-NC - MCCP6_4A - N7779 P111 MOTOR STARTER, CWS-1B, 05003458
N7780 105-NC 105-NC - MCCP6_6A - N7780 P111 MOTOR STARTER, CWS-1A, 05003460
N0535 105-NC 105-NC - MCCP6_8A - N0535 P111 VFD, CT-1A FAN, 05003461
N7783 105-NC 105-NC - MCCP7_3A - N7783 P111 MOTOR STARTER, CWS-1C, 05003426
N7785 105-NC 105-NC - MCCSC1_1A - N7785 P123 MOTOR STARTER, FVNR, NEMA 2, 10AT, 05003683 N7786 105-NC 105-NC - MCCSC1_1B - N7786 P123 MOTOR STARTER, FVNR, NEMA 2, 10AT, 05003684 N7787 105-NC 105-NC - MCCSC1_1C - N7787 P123 MOTOR STARTER, FVNR, NEMA 2, 10AT, 05003685 N7788 105-NC 105-NC -…
This is the start of the file's text. The full file is on GovTribe.