This is a Scope of Work for the purchase, delivery, setup, and utility connection of a prefabricated concrete restroom building at the Bear Creek Recreation area on Lake Greeson in Pike County, Arkansas, with a desired completion date of May 1, 2027. The contracting office point of contact is Matthew Flemens (matthew.d.flemens@USACE.ARMY.MIL).

The prefabricated building shall be concrete-constructed with two fully accessible restrooms featuring showers, complete plumbing and electrical systems, a 30-gallon water heater, interior and exterior LED fixtures, and anti-graffiti coating. Each restroom must include vitreous china toilets and lavatories, sanitary napkin disposal receptacles, stainless steel grab bars, electric hand dryers, and skylights. Exterior walls shall have board and batt texture on top with river rock texture on bottom; the roof shall have cedar shake texture. The building must withstand a 250 PSF roof snow load, 400 PSF floor load, 150 MPH winds (3-second gusts), and seismic group 1 design category E earthquakes. Concrete construction specifications include minimum 4-inch walls, 4.5-inch roof, and 5-inch floor thickness with centered steel reinforcement and 1.25-inch cover on the floor's under surface. Interior surfaces require 1-inch radius coving with high-strength grout, chemical-resistant urethane flooring, and modified acrylic water-repellent stain with clear acrylic anti-graffiti sealer on walls and ceilings. Hardware requirements include 18-gauge type 304 stainless steel grab bars capable of withstanding 300-pound top loading, quarter-inch thick stainless steel toilet paper dispensers holding three rolls, 1.75-inch thick flush panel doors of minimum 16-gauge galvanized steel with DTM alkyd paint, three hinges per door with dull chrome plating and automatic closing mechanisms, and adjustable brush-type door sweeps. Additional specifications include crank-operated wall vents with removable cranks, 14-gauge 304 stainless steel vent covers with insect screens and anti-rust fasteners, ADA-compliant signage with raised pictograms and braille, and window frames with vandal-resistant fasteners.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scope of Work for purchase and installation of Prefab Restroom

Purchase, delivery, set up and connection to utilities of a prefabricated building in the Bear Creek Recreation area on Lake Greeson in Pike County AR. The desired completion date is 1 May 2027. POC for this contract will be Matthew Flemens (matthew.d.flemens@USACE.ARMY.MIL)

The building shall be constructed with concrete and include two (2) fully accessible restrooms with showers, be completely plumbed and wired with a 30-gallon water heater, interior and exterior LED light fixtures, and be treated with an anti-graffiti coating. Each restroom shall include vitreous china toilet and lavatories, sanitary napkin disposal receptacle, stainless steel grab bars, electric hand dryer and skylight. The exterior wall shall have the texture of board and batt on top with a river rock Texture on bottom. The roof shall Have the texture of cedar shakes.

The building shall be designed to withstand a roof snow load of 250PSF, a floor load to withstand 400PSF, wind up to 150 MPH for 3 second gusts, the effects of a seismic group 1 design category E earthquake. The building shall be constructed out of concrete with a minimum 4” wall, 4½” roof, and 5” floor thickness. All wall to floor interior surface seams shall have a minimum 1” radius coving made of high strength grout. Steel reinforcement shall be centered in the cross-sectional area of the walls and will have at least 1¼” of cover on the under surface of the floor. Interior and exterior joints shall be caulked with a paintable polyurethane sealant. Grout shall be a non-shrink type and be painted to match the color of surrounding concrete as nearly as possible. Interior floors shall be a chemical resistant urethane. Interior walls and ceilings shall be a modified acrylic, water repellent penetrating stain followed by a clear acrylic anti-graffiti sealer. Exterior walls and roof shall be a water repellent penetrating stain in the same color as the walls or roof followed by a clear acrylic anti-graffiti sealer.

Grab bars shall be 18-gauge, type 304 stainless steel with 1½” clearance. Grab bars shall each be able to withstand 300-pound top loading. Toilet Paper Dispenser shall be constructed of ¼” thick, type 304 stainless steel. Dispenser will be capable of holding three (3) standard rolls of toilet paper. Toilet paper holder fastening system will be able to withstand 300-pound top loading. Doors shall be flush panel type 1¾” thick, minimum 16-gauge galvanized steel, top painted with DTM ALKYD. Door frames shall be knockdown or welded type, single rabbet, minimum 16-gauge prime coated steel top painted with DTM ALKYD, width to suit wall thickness. There shall be three (3) hinges per door with dull chrome plating 4½” x 4½”, adjustable tension, and automatic closing for each door. Door sweep shall be provided at the bottom of door and should be an adjustable brush type.

mailto:matthew.d.flemens@USACE.ARMY.MIL

Wall vent shall be crank operated allowing the unit to be opened or closed. Crank shall be removable. Vent cover shall be 14-gauge 304 stainless steel and anchored into the concrete wall with high strength anti-rust tap con fasteners. Vent should come with insect screen. Wall vent shall not protrude from the wall. Signs should have raised pictograms, letters, and braille to meet ADA. Window frames shall have vandal resistant fasteners.