SCO-DOT-FerryMannsHarborShipyard-Electrical+CompressedAirSystemUpgrades (11-2026).pdf
PDF 130 KB Posted
- Solicitation number
- SCO-DOT-Ferry Manns Harbor Shipyard-Electrical+Compressed Air System Upgrades (11-2026)
- Issued by
- Cumberland County, North Carolina
About this file
This is a Scope of Work document from the North Carolina Department of Transportation Ferry Division for design services related to infrastructure upgrades at Manns Harbor Shipyard. The project encompasses electrical infrastructure upgrades and compressed air system upgrades at the North Carolina Shipyard in Manns Harbor. The electrical work includes removal and installation of main service breakers, switchboards, manual transfer switches, panels, motor control centers, transformers, standby generators with fuel lines, exterior shore power receptacles, and associated conduits and connectors. The compressed air system work involves demolition of existing equipment and replacement with a modular air production system on a new concrete pad, along with identification and repair of distribution system leaks as funding permits. The Letter of Interest and three copies of the Standard Form 254 must be submitted by December 16, 2026 at 4:00 PM to the NCDOT Facilities Management Unit. Submissions should be mailed to 1525 Mail Service Center, Raleigh, NC 27699-1525, or delivered via FedEx/UPS to 1 S. Wilmington St, Room 406B, Raleigh, NC 27601.
The total project budget is $6,843,000, funded through Non-General Fund Agency Receipts. The solicitation was published on November 17, 2026 with the closing date of December 16, 2026. Proposing firms must be properly licensed to practice architecture, engineering, or landscape architecture in North Carolina. The selection committee will evaluate proposals based on specialized expertise, past performance on similar projects, adequate staffing, current workload, proposed design approach, experience with project costs and schedules, construction administration capabilities, proximity to and familiarity with the project location, and record of successfully completed projects. The Letter of Interest should not exceed ten single-sided pages or five double-sided pages, formatted as 8.5" x 11" pages stapled in the upper left corner, with no binders, tabs, or clips. Electronic and fax submissions will not be accepted.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department/Agency NC Department of Transportation – Ferry Division Project Title Manns Harbor Shipyard - Electrical Infrastructure Upgrades and Compressed Air System Upgrades Design Services Engineering
Scope of Work
Electrical Infrastructure Upgrades and Compressed Air System Upgrades at the Manns Harbor Shipyard located at the North Carolina Shipyard in Manns Harbor and operated by the NCDOT Ferry Division.
Electrical Infrastructure Upgrades to include the removal and installation of the main service breaker, switchboard, manual transfer switches, panels and motor control centers of various sizes, transformers, standby generators (including fuel lines), exterior shore power receptacles, and conduits and connectors.
Compressed Air System Upgrades to include demolition of existing air compressor, air dryer, coolant system and all associated tanks, and replacement of the system with a modular air production system which would require a concrete pad and will be connected to the existing distribution system.
Identifying and repairing leaks in the distribution system will be included as allowed by project funding.
Contact David Varel Telephone 919-707-4543 Email dvarel@ncdot.gov Total Project Budget $6,843,000 Source of Funds Non-General Fund, Agency Receipts Approved OC-25 # #20274280083 Publish Date November 17, 2026 Closing Date Wednesday – December 16, 2026 @ 4:00 PM Submit THREE (3) Copies of Letter of Interest and SF-254 (Mailing Address):
NCDOT Facilities Management Unit 1525 Mail Service Center Raleigh, NC 27699-1525
Physical Location for Fed Ex/UPS Delivery (Delivery Address):
NCDOT Facilities Management Unit 1 S. Wilmington St, Room 406B Raleigh, NC 27601
NC Licensing Statement
In order to offer architectural, engineering, or landscape architectural services in response to this solicitation, the proposing firm must be properly licensed to practice Architecture, Engineering, or Landscape Architecture in the State of North Carolina. More information on the North Carolina state boards may be found at the following websites:
NC Board of Architecture: (http://www.ncbarch.org) NC Board of Examiners for Engineers & Surveyors:
(http://www.ncbels.org) NC Board of Landscape Architects: (http://www.ncbola.org) mailto:dvarel@ncdot.gov http://www.ncbarch.org/ http://www.ncbels.org/ http://www.ncbola.org/
STATE BUILDING COMMISSION - SELECTING CRITERIA
In selecting designers, the selection committee should take into consideration qualification information including such factors as:
1. Specialized or appropriate expertise in the type of project.
2. Past performance on similar projects.
3. Adequate staff and proposed design or consultant team for the project.
4. Current workload and State projects awarded.
5. Proposed design approach for the project including design team and consultants.
6. Recent experience with project costs and schedules.
7. Construction administration capabilities.
8. Proximity to and familiarity with the area where the project is located.
9. Record of successfully completed projects without major legal or technical problems.
10. Other factors which may be appropriate for the project.
STATE BUILDING COMMISSION - SUBMITTAL CRITERIA
Proposing firms must submit THREE (3) copies of the Letter of Interest and THREE (3) copies of your current Standard Form 254 (SF 254) with the information package. The current SF 254 template is located at http://ncadmin.nc.gov/businesses/construction/forms-documents which is the State Building Commission approved form.
In the interest of cost-savings to the designers, consistency of the submittals and more efficient use of time by the pre-selection committee, the submitted information package should not include any notebooks, binders, tab, clips, etc. The format should be 8-1/2" x 11" pages stapled in the upper left-hand corner. The Letter of Interest should not exceed ten (10) single-sided pages or five (5) double-sided pages plus the SF 254.
E-mail and Fax submittals will not be accepted.
http://ncadmin.nc.gov/businesses/construction/forms-documents
| Manns Harbor Shipyard - Electrical Infrastructure Upgrades |
| Project Title |
| and Compressed Air System Upgrades |
| Design Services |
| Electrical Infrastructure Upgrades and Compressed Air System Upgrades at the Manns Harbor Shipyard located at the North Carolina Shipyard in Manns Harbor and operated by the NCDOT Ferry Division. |
| Electrical Infrastructure Upgrades to include the removal and installation of the main service breaker, switchboard, manual transfer switches, panels and motor control centers of various sizes, transformers, standby generators (including fuel lines), exterior shore power receptacles, and conduits and connectors. |
| Scope of Work |
| David Varel |
| Contact |
| 919-707-4543 |
| Telephone |
| dvarel@ncdot.gov |
| $6,843,000 |
| Total Project Budget |
| Non-General Fund, Agency Receipts |
| Source of Funds |
| Approved OC-25 # |
| Publish Date |
| Closing Date |
| Submit THREE (3) Copies of Letter of Interest and SF-254 (Mailing Address): |
| Physical Locationfor Fed Ex/UPS Delivery (Delivery Address): |
| NC Licensing Statement |
File details come from the government source that posted it. Updated .