Oxford Instruments
Plasma Technology PlasmaPro®100 Cobra
Issue: 01 / December 2017
Facilities Interface Specification www.oxford-instruments.com
©2012. Oxford Instruments Plasma Technology. All rights reserved.
Facilities Interface Specification
PlasmaPro®100 Cobra This page is intentionally blank.
Page ii Template Issue: 01
1.Facilities Interface Specification
1.1 Introduction
This Facilities Interface Specification (FIS) provides the data required to forward plan the facilitisation of the PlasmaPro®100 Cobra tool. It contains SEMI E6-0914 compliant Facilities Data Sheets covering PlasmaPro®100 Cobra system installation and has been written to ensure compliance with all relevant SEMI standards, including but not limited to E6, E76, S10 & S13.
Note The information contained within this manual is accurate at time of placement of order.
1.2 Customer Support
Oxford Instruments Plasma Technology has global customer support that provide a coordinated response to customer’s queries. All queries are recorded on our support database and are dealt with as quickly as possible. If we are not able to answer the query immediately, we will contact you promptly.
Please direct all queries through your nearest support facility (see below), and have the following details available::
You can contact us on the following telephone number:
Tool type PlasmaPro®100 Cobra
Works order number 94-220288
Contact information Your name, the name of your company, and how we can contact you.
Details of your query The nature of your problem, part numbers of spares required, etc.
Oxford Instruments Plasma Technology
US, Canada and Latin America Concord, MA
TOLLFREE: +1 800 447 4717
Template Issue: 01 Page 1
1.3 Preparing the site
The site where the tool is to be located must be surveyed and prepared before the tool is delivered. In particular, ensure that the following issues are resolved before commencing the installation:
• Ensure that the positions and fixing arrangements of all tool components are defined. Make sure that all parts of the tool are considered, including components that are mounted remotely.
• Ensure that the location of the tool allows easy access to the customer supplied isolation devices for all services (the electrical isolator; and the isolation valves for the cooling water, CDA, nitrogen, and process gas supplies).
• Assess loadings on the floor, and on any walls or support structures, to sure they are sufficient to support the weight of the various tool components.
• Make sure that all required safety features, such as gas detection equipment are installed and operational when the tool arrives.
• Make sure that the routing of interconnecting cables and pipework between the various tool components has been properly considered. Pipework or cables must not be routed where personnel are liable to walk or require regular access. Pipework and cabling must not impede access to tool safety features, such as emergency off buttons, circuit breakers or gas shut-off valves.
• Separate AC power cables from low voltage signal cables.
• Make sure the site allows sufficient clearance around all the main tool components (See Data Sheet 300).
• Make sure that the site is well ventilated and allows the free movement of air around the tool. The volume of the room must be at least 9 m3. The room must be ventilated with at least 4 air changes per hour, to keep the oxygen concentration high.
• Make sure that all the services required for tool operation are available and meet the required specifications (see Data Sheets 400-1000).
• Ensure that the procedures, personnel and equipment required for safely connecting the tool services have been planned. It may be necessary to shut down other equipment in the facility in order to connect exhausts, gas lines, water or electrical power to the tool.
• Check that the route, equipment and personnel required for safely transporting the equipment from the loading dock to the installation site are satisfactory.
Care must be taken to consider floor loadings and access along the entire route.
• If the tool is to be installed in a clean room, consider the impact on other equipment and processes in the facility before commencing installation.
1.4 Installation
This section explains how to move the PlasmaPro®100 Cobra tool into position and connect to the customer supplied services.
Template Issue: 01 Page 2
1.4.1 Storage information
The PlasmaPro®100 Cobra is shipped in sealed, evacuated plastic bags within a wooden packing case. The bags contain silica gel to protect the tool from moisture. Store the tool in a facility that meets the following requirements.
• Temperature controlled between 0°C and 50°C (32°F to 122°F).
• A dry area that protects the crates from the weather (rain and dust).
1.4.2 Moving the tool into position
When transporting or moving the tool, ensure that it remains vertical at all times. The base unit can topple if tilted, causing severe injury. The main frame is fitted with wheels for use on flat surfaces.
1.4.3 Removing the tool’s wheels
• Using a suitable spanner, lower the four feet until they support the weight of the frame.
• Remove the four screws that secure each of the two rear wheel assemblies to the frame. Remove the two wheel assemblies (see Figure A-1).
Fig 1 Tool wheels
• Remove the four screws that secure each of the two front wheel assemblies to the frame. Remove the two wheel assemblies.
• Place a spirit level or inclinometer on a horizontal part of the frame and adjust the four feet until the base unit is level.
Template Issue: 01 Page 3
Note The tool is shipped with the process chamber under vacuum, so the chamber lid cannot be opened. During the commissioning process, an OIPT engineer will re-level the tool using the upper surface of the substrate table as the datum point.
• Lock the adjustable feet in place. Recheck that the frame is level.
• Attach the bolt-down brackets to the tool.
• Bolt the tool to the floor with six M10 x 40 mm hexagonal headed screws through the bolt-down brackets.
Note The process module must be bolted to the floor to avoid a safety hazard caused by failure of the turbo pump and if located in a seismic region.
Template Issue: 01 Page 4
Fig 2 Typical System Fixing Positions Template Issue: 01 Page 5
1.5 Data Sheet 100 - Equipment Identification
Data Sheet 100 - Equipment Identification
Data Type Units
A Install Data ID text System Facilities Data
B Install Data Rev. text 01
C Data Rev. date text December 2017
D SEMI Std. text SEMI E6-0914
E Equip. Name text PlasmaPro®100 Cobra
F Equip Model No. text
G Process Type text Plasma Etch
H Wafer Size mm 200
I No. of Equip.
Components
# 6
J Equip.
Comments text
K Supplier Name text Oxford Instruments Plasma Technology
L Supplier Address text North End, Yatton, Bristol, UK.
M Supplier Mail Code text BS49 4AP
N Supplier Phone text +44 (0) 1934 837000
O Admin. Interface Ref.
text N/A
P Customer Name text NIST(USA)
Q Customer PO No. text
R Cust. Equip. ID. text 94-220288
S Cust. Equip. ID.
Serial No.
text N/A Template Issue: 01 Page 6
1.6 Data Sheet 200 - Environmental Conditions
Note It should be noted that the environmental data in the following tables is based on installations carried out at altitudes between sea level and 3000 metres. For installations above 3000 metres specific approval should be sought from OIPT.
Data Sheet 200 - Environmental Conditions (Sheet 1 of 2)
Data Type Units Environmental Conditions
A Element ID. text Cobra Control Rack Loadlock Pump
Chamber Pump
B Max. Distance metre 5 5 5 5
C Min. Cleanroom Spec.
text 1000 1000 1000 1000
D Cleanroom Classification
Standard text Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
E Target Room Temp.
ºC 20 20 20 20
F Min. Room Temp ºC 15 15 5 5
G Max. Room Temp. ºC 25 25 25 25
H Room Temp.
Fluctuation
º/hr 5 5 5 5
I Heat Loading Idle watts 1500
J Heat Loading Process watts 3500
K Target Room Humidity
% 45 45 45 45
L Min. Room Humidity
% 10 10 10 10
M Max. Room Humidity
% 80 80 80 80
N Humidity Fluctuation
%/hr 10 10 10 10
O Vibration Sensitivity text
P Vibration Generation text
Q Other Vib. Req. text
R Other Conditions text Min. Light Level 300 Lux
Min. Light Level 300 Lux
Min. Light Level 300 Lux
Min. Light Level 300 Lux
S Env. Cond.
Comments text Template Issue: 01 Page 7
A Element ID. text Chiller Gas Pod LN2 ACU Pump Purge
B Max. Distance metre 10 10 10 10
C Min. Cleanroom Spec.
text 1000 1000 1000 1000
D Cleanroom Classification
Standard text Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
Fed Std 209E or ISO 14644
E Target Room Temp.
ºC 20 20 20 20
F Min. Room Temp ºC 5 5 5 5
G Max. Room Temp. ºC 25 25 25 25
H Room Temp.
Fluctuation
º/hr 5 5 5 5
I Heat Loading Idle watts
J Heat Loading Process watts
K Target Humidity % 45 45 45 45
L Min. Humidity % 10 10 10 10
M Max. Humidity % 80 80 80 80
N Humidity Fluctuation
%/hr 10 10 10 10
O Vibration Sensitivity text
P Vibration Generation text
Q Other Vibration Requirement text
R Other Conditions text Min. Light Level 300 Lux
Min. Light Level 300 Lux
Min. Light Level 300 Lux
Min. Light Level 300 Lux
S Env. Cond.
Comments text
Data Sheet 200 - Environmental Conditions (Sheet 2 of 2)
Data Type Units Environmental Conditions Template Issue: 01 Page 8
Fig 3 System Footprint Template Issue: 01 Page 9
1.Data Sheet 300 - Physical Characteristics
Data Sheet 300 - Physical Characteristics (Sheet 1 of 2)
Data Type Units Physical Characteristics
A Element ID. text Cobra Tool Control Rack
Loadlock Pump
Chamber Pump
B Shipping Data Ref. text
C No. of Containers #
D Installation Instructions Ref.
text
E No. of Cleanroom Items
# 1 1 1 1
F Max Move-in Length mm 1749 639 430 742
G Max Move-in Width mm 653 612 281 300
H Max Move-in Height mm 1630 1091 302 395
I Max Move-in Weight kg 636 75 25 120
J ESH Information Ref. text See the Operator Manual
See the Operator Manual
See the
OEM
Manual
See the
OEM
Manual
K Assembled Length mm 1749 639 430 742
L Assembled Width mm 653 612 281 300
M Min. Assembled Height mm 1590 1091 302 395
N Max. Assembled Height mm 1600 1102 302 395
O Assembled Weight kg 616 75 25 120
P Clearance Front mm 1000 1000 1000
Q Clearance Right mm 1000 0 1000 1000
R Clearance Left mm 1000 0 1000 1000
S Clearance Back mm 1000 1000 1000 1000
T Clearance Top mm 1000 1000 1000 1000
U Clearance Bottom mm N/A N/A N/A N/A
V Floor Loading Ref. text Refer to section 1.7.1
Refer to section 1.7.2
Refer to section 1.7.3
Refer to section 1.7.3
W Drawing Refs. text
X Comments text Template Issue: 01 Page 10
A Element ID. text Chiller Gas Pod LN2 ACU Pump Purge
B Shipping Data Ref. text
C No. of Containers #
D Inst. Instructions Ref. text
E No of Cleanroom Items.
# 1 1 1 1
F Max Move-in Length mm 550 650 470 201
G Max Move-in Width mm 465 264 236 185
H Max Move-in Height mm 881 1428 642 70
I Max Move-in Weight kg 90 70
J ESH Info. Ref. text See the
OEM
Manual
See the Operator Manual
See the Operator Manual
See the Operator Manual
K Assembled Length mm 550 650 470 201
L Assembled Width mm 465 264 236 185
M Min. Assembled Height mm 881 1428 642 70
N Max. Assembled Height mm 881 1428 642 70
O Assembled Weight kg 90 70
P Clearance Front mm 1000 1000 1000 500
Q Clearance Right mm 1000 1000 500 0
R Clearance Left mm 1000 0 500 0
S Clearance Back mm 1000 0 0 500
T Clearance Top mm 1000 0 500 500
U Clearance Bottom mm N/A 300 500 N/A
V Floor Loading Ref. text Refer to section 1.7.4
Refer to section 1.7.5
Refer to section 1.7.6
Refer to section 1.7.6
W Drawing Refs. text
X Comments
Data Sheet 300 - Physical Characteristics (Sheet 2 of 2)
Data Type Units Physical Characteristics Template Issue: 01 Page 11
1.6.1 PlasmaPro®100 Cobra Tool Positioning Data
PlasmaPro®100 Tool Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum) 0 0 124.8 70
B 1025 -82 163.6 70
C 0 -600 124.8 70
D 1025 -518 163.6 70 Template Issue: 01 Page 12
Fig 4 PlasmaPro®100 Cobra Tool Dimensions Template Issue: 01 Page 13
1.6.2 Control Rack Positioning Data.
Control Rack Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum) 0 0 32
B 535 0 32
C 0 -535 32
D 535 -535 32 Template Issue: 01 Page 14
Fig 5 Control Rack Dimensions Template Issue: 01 Page 15
1.7 Pump Positioning Data
Process Module Pump Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum) 0 0 37
B 510 0 37
C 0 -334 37
D 510 -334 37
Loadlock Pump Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum) 0 0 12
B 224 0 12
C 0 -150 12
D 224 -150 12 Template Issue: 01 Page 16
Fig 6 Pump Dimensions Template Issue: 01 Page 17
1.7.1 Chiller Positioning Data
Chiller Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
No feet for this component. Overall weight 90 kgs.
Template Issue: 01 Page 18
Fig 7 Chiller Dimensions Template Issue: 01 Page 19
1.7.2 Gas Pod Positioning Data.
Gas Pod Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
No feet for this component. Overall maximum weight 70 kgs.
Template Issue: 01 Page 20
Fig 8 Gas Pod Dimensions Template Issue: 01 Page 21
1.7.3 LN2 ACU Positioning Data
LN2 ACU Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum)
No feet for this component. Overall weight 35 kgs.B
C
D
Template Issue: 01 Page 22
Fig 9 LN2 ACU Dimensions Template Issue: 01 Page 23
1.7.4 Pump Purge Positioning Data
Pump Purge Box Floor Loading Information
Foot Ref. X (mm)
Y (mm)
Weight (Kg)
Foot Diameter (mm)
A (Datum) 0 0 9
B 115 0 9
C 0 -130 9
D 115 -130 9 Template Issue: 01 Page 24
Fig 10 Pump Purge Box Dimensions Template Issue: 01 Page 25
1.8 Data Sheet 400 - Electrical Power
Note A suitably rated circuit breaker must be installed as part of the electrical supply to the tool before the main circuit breaker on the OIPT supplied electrical rack.
Note The electrical supply cable must be rated to carry more than the tools incoming circuit breaker value in accordance with local electrical rules and regulations. It is the responsibility of the customer to make sure it is suitably rated prior to installation of the tool.
Note The control rack is supplied with five metres of interconnecting cables as standard, which allowing for cable drops, leaves three metres between the rack and other system parts. However, the effective distance between parts may be further reduced to avoid obstructions or if cables are routed via cable trays.
Note An input from a fire alarm system can be linked in to the OIPT EMO circuit if required.
Template Issue: 01 Page 26
Data Sheet 400 - Electrical Power
Data Type Units Electrical Power
A Element ID. text Control Rack
B Connection Number text 401
C Connection Label text XEP100
D Utility Type text Normal Power
E Line Source text Facilities
F Voltage/Phase/ Wire volts 208V 3 Phase, Neutral + Ground (5 wire)
G Frequency Hz 60
H Equipment Component
Connection Type text Isolator
I Interrupting Capacity kA
J MCCB amp 50
J Electrical Connection
Positioning Data text Refer to Fig 11 Template Issue: 01 Page 27
Fig 11 Electrical Connection Point Template Issue: 01 Page 28
1.9 Data Sheet 500 - Water
Data Sheet 500 - Water
Data Type Units Water
A Element ID. text Cobra Tool Chamber Pump
B Connection Number text 501/502 503/504
C Connection Label text WATER IN/
OUT
IN/OUT
D Utility Type text Chilled Water
Chilled Water
E Line Source text Facilities Facilities
F Purity text 100 microns microns
G Contaminants text 30 ppm ph 6- 8
30 ppm ph 6 - 8
H Minimum Pressure kPa 200 200
I Maximum Pressure kPa 300 300
J Max. Pressure Fluctuation kPa 30 30
K Min. Pressure Differential kPa 172
L Avg. Flow Idle lpm 23 1
M Avg Flow Proc. lpm 23 1
N Max. Flow. lpm 23 1
O Max Temperature
ºC 25 25
P Min.
Temperature
ºC 15 15
Q Equip. Comp.
Fitting Size inches 3/4 3/8
R Equip. Comp.
Fitting Matl.
text Stainless Steel
Stainless Steel
S Equip. Comp.
Fitting Type text Barbed NPT
T Drawing Reference text
U Comments text Template Issue: 01 Page 29
Fig 12 Water Connection Points Template Issue: 01 Page 30
1.10 Data Sheet 600 - Bulk Chemicals
Data Sheet 600 - Bulk Chemicals
Data Type Units Chemical Data
A Element ID. text LN2 ACU Cobra Tool
B Connection Number text 601/602 605/606
C Connection Label text LN2
SUPPLY/
EXHAUST
COOLANT
IN/OUT
D Utility Type text LN2 LN2
E Line Source text Facilities 603/604
F Purity text
G Contaminants text
H Min. Pressure KPa 200
I Max. Pressure KPa 300
J Max.Pressure Fluctuation
KPa
K Min. Pressure Differential
KPa
L Idle Avg. Flow lpm
M Process Avg.
Flow lpm
N Max. Flow lpm
O Max. Temp °C
P Equip. Comp.
Fitting Size text 3/8" 3/8"
Q Equip. Comp.
Fitting Matl.
text Stainless Steel
Stainless Steel
R Equip. Comp.
Fitting Type text Double Ferrule
Double Ferrule
S Double Containment
Y/N N N
T Equip. Comp.
Double. Cont.
Size mm N/A N/A
U Equip. Comp.
Double. Cont.
Matl.
text N/A N/A
V Equip. Comp.
Double. Cont.
Type.
text N/A N/A Template Issue: 01 Page 31
W Drawing Refs. text
X Comments text
Data Sheet 600 - Bulk Chemicals
Data Type Units Chemical Data Template Issue: 01 Page 32
Fig 13 Bulk chemicals connection points Template Issue: 01 Page 33
Fig 14 ACU Positioning Details Template Issue: 01 Page 34
1.11 Data Sheet 700 - Drains
No drains are used on the Cobra System; therefore, Data Sheet 700 is not applicable.
Template Issue: 01 Page 35
1.12 Data Sheet 800 - Gases
1.12.1 General Gases
Data Sheet 800 - General Gases
Data Type Units Gas Data
A Element ID. text Cobra Tool
Cobra Tool
Cobra Tool
Cobra Tool
Pump Purge
LN2
ACU
B Connection Number text 801 802 803 804 805 806
C Connection Label text AIR IN PSM AIR
IN
N2 HELIUM IN DRY N2
SUPPLY
D Utility Type text CDA CDA N2 He N2 N2
E Line Source text Facilities Facilities Facilities Facilities Facilities Facilities
F Gas State text Pure Gas
Pure Gas
Pure Gas
Pure Gas
Pure Gas
Pure as
G Purity text CDA CDA 99.99% 99.99% 99.99% 99.99%
H Contaminants text
I Filtration microns 0.3 0.3 2.0 2.0 2.0 2.0
J Min. Pressure KPa 600 600 200 200 200 200
K Max. Pressure KPa 600 600 300 300 300 300
L External Regulator text Not Required
Not Required
Required Required Required Required
M Idle Avg. Flow lpm
N Process Avg.
Flow lpm
O Max. Flow lpm 135 60 10 0.05 4.0
P Equip. Comp.
Fitting Size mm/ inch
10mm 10mm 1/4" 1/4" 10mm 10mm
Q Equip. Comp.
Fitting Matl.
text Plastic Plastic Stainless Steel
Stainless Steel
Plastic Plastic
R Equip. Comp.
Fitting Type text Push Fit Push Fit Double Ferrule
Double Ferrule
Push Fit Push Fit
S Double Containment
Y/N N N N N N N
T Equip. Comp.
Double
Containment Size mm/ inch
N/A N/A N/A N/A N/A N/A Template Issue: 01 Page 36
U Equip. Comp.
Double
Containment Matl.
text N/A N/A N/A N/A N/A N/A
V Equip. Comp.
Double
Containment Type text N/A N/A N/A N/A N/A N/A
W Drawing Refs text
X Comments text
Data Sheet 800 - General Gases
Data Type Units Gas Data Template Issue: 01 Page 37
Fig 15 General Gas Connection Points Template Issue: 01 Page 38
1.12.2 Process Gas Data Sheet
Note OIPT only recommend the use of orbitally welded VCR fittings for all gas line installations from source to gas pod. Only fit correctly rated regulators. It is also recommended a wall-mounted isolation valve, high-flow valve and non-return valve to be fitted in each gas line. Failure to provide this equipment may result in unnecessary delays in the commissioning of the system Gas Data Sheet.
Data Sheet 800 - Process Gas Data Sheet (Sheet 1 of 2)
Data Type Units Process Gas Data
A Element ID. text Gas Pod Gas Pod Gas Pod Gas Pod Gas Pod
B Connection Number text 806 807 808 809 810
C Connection Label text B C l 3 S i C l 4 H B r C l 2 C H 4
D Utility Type text
E Line Source text Facilities Facilities Facilities Facilities Facilities
F Gas State text Pure Gas Pure Gas Pure Gas Pure Gas Pure Gas
G Purity text 99.999% 99.999% 99.999% 99.999% 99.999%
H Contaminants text
I Filtration microns 2.0 2.0 2.0 2.0 2.0
J Min. Pressure KPa 200 200 200 200 200
K Max. Pressure KPa 300 300 300 300 300
L External Regulator text Required Required Required Required Required
M Idle Avg. Flow lpm 0 0 0 0 0
N Process Avg.
Flow lpm Process Dependant
Process Dependant
Process Dependant
Process Dependant
Process Dependant
O Max. Flow lpm 0 . 0 5
P Equip. Comp.
Fitting Size inch 1/4 1/4 1/4 1/4 1/4
Q Equip. Comp.
Fitting Matl.
text 316 Stainless
Steel
Stainless
Steel
Stainless
Steel
Stainless
Steel
Stainless
Steel
R Equip. Comp.
Fitting Type text VCR VCR VCR VCR VCR
S Double Containment
Y/N Y Y Y Y Y
B C l 3 S i C l 4 H B r C l 2 C H 4
0 . 0 5 0 . 0 5 0 . 0 50 . 0 5 Template Issue: 01 Page 39
T Equip. Comp.
Double Cont.
Size inch 1/2
U Equip. Comp.
Double Cont.
Matl.
text Stainless
V Equip. Comp.
Double Cont.
Type text VCR VCR VCR VCR VCR
W Drawing Refs. text
X Comments text
Data Sheet 800 - Process Gas Data Sheet (Sheet 2 of 2)
Data Type Units Process Gas Data
1/2 1/2 1/2 1/2
StainlessStainlessStainlessStainless Template Issue: 01 Page 40
Data Sheet 800 - Process Gas Data Sheet (Sheet 1 of 2)
Data Type Units Process Gas Data
A Element ID. text Gas Pod Gas Pod Gas Pod Gas Pod Gas Pod
B Connection Number text 811 812 813 814 815
C Connection Label text H2 He Ar
D Utility Type text H2 He Ar
E Line Source text Facilities Facilities Facilities
F Gas State text Pure Gas Pure Gas Pure Gas
G Purity text 99.999% 99.999% 99.999%
H Contaminants text
I Filtration microns 2.0 2.0 2.0
J Min. Pressure KPa 200 200 200
K Max. Pressure KPa 300 300 300
L External Regulator text Required Required Required
M Idle Avg. Flow lpm 0 0 0
N Process Avg.
Flow lpm Process Dependant
Process Dependant
Process Dependant
O Max. Flow lpm 0.05 0.2 0.1
P Equip. Comp.
Fitting Size inch 1/4 1/4 1/4
Q Equip. Comp.
Fitting Matl.
text 316 Stainless
Steel
Stainless
Steel
Stainless
Steel
R Equip. Comp.
Fitting Type text VCR VCR VCR
S Double Containment
Y/N N N N
T Equip. Comp.
Double Cont.
Size inch N/A N/A N/A
U Equip. Comp.
Double Cont.
Matl.
text N/A N/A N/A
V Equip. Comp.
Double Cont.
Type text N/A N/A N/A
W Drawing Refs. text
O2
O2
Pure Gas
99.999%
2.0
Required
Process
0.1
1/4
Steel
VCR
N
Stainless
N/A
N/A
N/A
N/A
N/A
N/A
1/4
Stainless
Steel
VCR
N
Required
Process
0.5
2.0
CF4
CF4
Pure Gas
99.999% Template Issue: 01 Page 41
X Comments text
Data Sheet 800 - Process Gas Data Sheet (Sheet 2 of 2)
Data Type Units Process Gas Data Template Issue: 01 Page 42
Data Sheet 800 - Process Gas Data Sheet
Data Type Units Process Gas Data
A Element ID. text Gas Pod Gas Pod Gas Pod Gas Pod Gas Pod
B Connection Number text 816 817
C Connection Label text
D Utility Type text
E Line Source text
F Gas State text
G Purity text
H Contaminants text
I Filtration microns
J Min. Pressure KPa
K Max. Pressure KPa
L External Regulator text
M Idle Avg. Flow lpm
N Process Avg.
Flow lpm
O Max. Flow lpm
P Equip. Comp.
Fitting Size inch
Q Equip. Comp.
Fitting Matl.
text
R Equip. Comp.
Fitting Type text
S Double Containment
Y/N
T Equip. Comp.
Double Cont.
Size inch
U Equip. Comp.
Double Cont.
Matl.
text
V Equip. Comp.
Double Cont.
Type text
W Drawing Refs. text
X Comments text
SF6 N2
SF6 N2
Facilities Facilities
Pure Gas Pure Gas
99.999% 99.999%
2.0 2.0
200 200
300 300
Required Required
0 0
Process Dependant
Process Dependant
0.05 0.1
1/4 1/4
Stainless
Steel
Stainless
Steel
VCR VCR
N N
N/A N/A
N/A N/A
N/A N/A Template Issue: 01 Page 43
Fig 16 Gas connection Points Template Issue: 01 Page 44
1.13 Data Sheet 900 - Vacuum
Data Sheet 900 - Vacuum
Data Type Units Vacuum Connection Data
A Element ID. text Cobra Tool Cobra Tool
B Connection Number text 901 902
C Connection Label text Loadlock Pump
Chamber Pump
D Utility Type text Loadlock Vacuum
Process Vacuum
E Line Source text Loadlock Pump
Chamber Pump
F Vacuum Conveyed
Process Wastes text N/A N/A
G Min. Vacuum Pa
H Max. Vacuum Pa
I Max. Vacuum Fluctuation
Pa
J Max. Flow cmh
K Heating/ Insulating text No No
L Equip. Comp.
Fitting Size mm 25 40
M Equip. Comp.
Fitting Matl.
text Stainless Steel Stainless Steel
N Equip. Comp.
Fitting Type text NW NW
O Drawing Refs. text
P Comments text Template Issue: 01 Page 45
Fig 17 Vacuum Connection Points Template Issue: 01 Page 46
Data Sheet 1000 - Exhaust Data Sheet 1000 - Exhaust
Data Type Units Exhaust Connection Data
A Element ID. text Loadlock Pump
Chamber Pump
Gas Pod
B Connection Number text 1001 1002 1003
C Connection Label text
D Utility Type text Loadlock Pump Exhaust
Process Pump Exhaust
Gas Pod Extraction
E Line Source text Facilities Facilities Facilities
F Process Wastes text N/A Process Dependant
N/A
G Min. Static Pressure
Pa
H Max Static Pressure
Pa Refer to OEM manual
Refer to OEM manual
-375
I Max. Pressure Fluctuation
Pa LEV Dependant
LEV
Dependant
LEV
Dependant
J Avg. Idle Flow cmh
K Avg. Process Flow cmh Refer to OEM manual
Refer to OEM manual
L Max. Temperature ºC Ambient Ambient Ambient
M Equip. Comp.
Fitting Size mm 25 40 100
N Equip. Comp.
Fitting Size Dimension
ID/
OD
O Equip. Comp.
Fitting Matl.
text Stainless Steel Stainless Steel Customer Dependant
P Equip. Comp.
Fitting Type text KF NW Pipe Clamp
Q Flow Loss Coefficient
R External Damper Required
Y/N
S Drawing Refs. text
T Comments text Template Issue: 01 Page 47
Fig 18 Exhaust Connection Points Template Issue: 01 Page 48
1.14 Document History
Issue Draft 27/11/17
Draft issue.
Issue 01 19/12/17 First issue.
Template Issue: 01 Page 49
This page intentionally blank Template Issue: 01 Page 50
GLOSSARY
This glossary explains the acronyms and abbreviations used in this Facilities Interface Specification The entries are presented in alphanumeric order.
Acronyms and abbreviations ACU Automatic Changeover Unit Admin Administrative Avg Average C Centigrade CDA Clean Dry Air (compressed air) cmh cubic metre per hour Comp Component Cond Condition Env Environment Equip Equipment E-Off Emergency off Equip Equipment ESH Environment, Safety and Health Fed Federal FIS Facilities Interface Specification He Helium hr Hour Hz Hertz ID Identification ISO International Organisation for Standardisation kg Kilograms kPa Kilopascal LEV Local Exhaust Ventilation lpm litres per minute Matl Material Max Maximum MCCB Moulded Case Circuit Breaker Min Minimum mm Millimetre MTP Material Transfer Plane N/A Not applicable N No No Number OEM Other equipment manufacturer OIPT Oxford Instruments Plasma Technology Pa Pascal PCW Process Cooling Water ph power of hydrogen PO Purchase Order Proc Process Page 51Template Issue: 01
Ref Reference Rev Revision sccm Standard Cubic Centimetres per Minute SEMI Semiconductors Equipment and Materials International Spec Specification Std Standard TBD To be determined Temp Temperature V Volt VCR A trademark of the Swagelok company. In this manual, the term VCR refers to a vacuum connection system using a metal gasket as the seal Y Yes Page 52 Template Issue: 01
| This page is intentionally blank. |
| 1. Facilities Interface Specification |
| 1.1 Introduction |
| 1.2 Customer Support |
| 1.3 Preparing the site |
| 1.4 Installation |
| 1.4.1 Storage information |
| 1.4.2 Moving the tool into position |
| 1.4.3 Removing the tool’s wheels |
| 1.5 Data Sheet 100 - Equipment Identification |
| 1.6 Data Sheet 200 - Environmental Conditions |
| 1. Data Sheet 300 - Physical Characteristics |
| 1.6.1 PlasmaPro®100 Cobra Tool Positioning Data |
| 1.6.2 Control Rack Positioning Data. |
| 1.7 Pump Positioning Data |
| 1.7.1 Chiller Positioning Data |
| 1.7.2 Gas Pod Positioning Data. |
| 1.7.3 LN2 ACU Positioning Data |
| 1.7.4 Pump Purge Positioning Data |
| 1.8 Data Sheet 400 - Electrical Power |
| 1.9 Data Sheet 500 - Water |
| 1.10 Data Sheet 600 - Bulk Chemicals |
| 1.11 Data Sheet 700 - Drains |
| 1.12 Data Sheet 800 - Gases |
| 1.12.1 General Gases |
| 1.12.2 Process Gas Data Sheet |
| 1.13 Data Sheet 900 - Vacuum |
| 1.14 Document History |
| Glossary |
| Acronyms and abbreviations |
File details come from the government source that posted it.