The procurement requires two deliverables: six T-Type Filter units (P/N 4558824GW-16-13TG-10DM) manufactured by Norman Filter, and three Repair Kits (P/N KIT-45-588-M) also from Norman Filter Company. The filters are 4500 Series 588 Size Grayloc units rated for 6000 PSI working pressure with a nominal 10 micron/absolute 25 micron rating. Construction specifications include 316/316L stainless steel housing per AMS QQ-S-763, PTFE O-ring material, and wire-pleated woven wire mesh 316L stainless steel elements. Each filter shipment must include a Manufacturer's Certificate of Compliance documenting part number, quantity, manufacturing location, lot/heat/batch/date code/serial numbers, and customer order number. Sellers must provide evidence of proof pressure testing (1.5X MAWP hydrostat or 1.1X MAWP pneumastat) and certification that components comply with ASME Boiler and Pressure Vessel Code Section VIII Division 1, ASME B31 or B16 series, or meet a 4:1 burst pressure safety factor. Upon receipt at Kennedy Space Center, all items must be cleaned to ISO14952 Level 300A latest revision. The delivery date must be prior to WD2.

View the file

Other files

File Type Posted
SATPC0043073 Tab 10 Open Market RFQ.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements Needed to support LSR 202606401closure and in field replacement.

2. Characteristics, Scope, and Specs

Quantity OEM Part # Product Description

4558824GW-16-

13TG-10DM

FILTER, T TYPE

P/N: 4558824GW-16-13TG-10DM

MFG: NORMAN FILTER

DESC: WORKING PRESSURE: 6000 PSI

4500 SERIES 588 SIZE GRAYLOC

MICRON RATING: NOMINAL 10 /ABSOLUTE 25

COLLAPSE PRESSURE: 4500 PSID

MATERIAL: PTFE O-RING

HOUSING MATERIAL: 316/316L STAINLESS STEEL

PER AMS QQ-S-763

ELEMENT MATERIAL: WIRE PLEATED WOVEN

WIRE MESH 316L STAINLESS STEEL

REQUIRES MANUFACTURER C OF C.

REQUIRES PROOF PRESSURE TEST (1.5 X MAWP

HYDROSTAT OR 1.1 X MAWP PNEUMASTAT).

REQUIRES A LETTER OF CERTIFICATION,

DRAWING, OR CUT SHEET STATING VALVE

COMPONENT ASME BOILER AND PRESSURE

VESSEL CODE SECTION VIII DIV1, ASME B31 SERIES

OR ASME B16 SERIES OR HAS A BURST PRESSURE

SAFETY FACTOR OF 4:1.

UPON RECEIPT AT KSC, CLEAN TO ISO14952

LATEST REV LEVEL 300A.

QC03 Manufacturer’s Certificate of Compliance The Manufacturer shall provide a certification with each shipment to attest that the parts, assemblies, subassemblies, or detail parts conform to the Order requirements. When applicable, the true manufacturers, lot, heat, batch, date code, and/or serial number must appear on the certification.

Certification must contain the following:

• Part number / Specification

• Quantity

• Name and address of manufacturing or processing location

• Manufacturer’s lot, heat, batch, date code, and/or serial number (if applicable)

• Customer’s Order number when ordering directly from the manufacturer.

• If Authorized Distributor, include Authorized Distributor

Name and Evidence from the OEM that seller is an Authorized Distributor – attached to Certificate.

QC07 Evidence of Test

The Seller shall provide results of inspections and tests (e.g., nominal operating load or pressure, maximum proof load or pressure the hardware was subjected to, electrical resistance, continuity & nondestructive testing/reports) performed by the Seller in accordance with the Order and specification requirements.

QC18 Pressure Vessel Requirements With each shipment, the Seller shall provide a letter of certification, drawing, or cut sheet stating component meets one of the following (as applicable):

• ASME Boiler and Pressure Vessel Code Section VIII Div

• ASME Boiler and Pressure Vessel Code Section XIII

• ASME B31 series or ASME B16 series or CGA

• Burst Pressure Safety Factor of 4:1

3 KIT-45-588-M

REPAIR KIT

P/N: KIT-45-588-M

MFR: NORMAN FILTER COMPANY

DESC: REPAIR KIT

3. Place of Performance Kennedy Space Center. VAB ML1

4. Period of Performance Deliverable date. Prior to WD2.