This Statement of Work describes NASA GSFC Code 675's requirement to purchase a Manncorp MC385V1V Mid-Volume Pick & Place system with associated feeders and accessories to restore in-house automated printed circuit board assembly capability for prototype, engineering, and flight applications. The contractor must provide delivery, installation, setup, functional verification, and operator training. The complete system includes one MC385V1V machine, one FR32K 32-port feeder base, two cut strip holders for 8mm lanes, two 8mm tape feeders with small windows for 0201/0402 components, fifteen standard 8mm tape feeders, four 12mm tape feeders, and one universal IC/tube feeder with 10 lanes. The system shall include standard vision alignment with COGNEX on-the-fly camera, fiducial recognition, CAD conversion software, component library, feeder optimization tools, Windows-based control software, computer controller with LCD display, keyboard, mouse, and network adapter, and remote service support software.
The contractor shall perform all installation and configuration during a single site visit at Goddard Space Flight Center, including positioning, leveling, calibration, feeder installation, software configuration, and successful component placement demonstration. On-site training shall be provided to Chris Pirner covering machine operation, PCB programming/CAD import, component library creation, feeder setup, vision/fiducial setup, maintenance, troubleshooting, and normal operation. The period of performance is 15 weeks as required (ARO), with completion required by November 18, 2026. Successful functional checkout and component placement demonstration shall verify installation completion; a separate formal Site Acceptance Test is not required. NASA shall provide the required compressed-air supply prior to installation, and remote service access is not required.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements
NASA GSFC, Code 675 Electric Field Laboratory, requires the purchase of a Manncorp MC385V1V Mid-Volume Pick & Place system to reestablish lost in-house automated component-placement capability for prototype, engineering, and flight printed circuit board assemblies.
The contractor shall provide the complete system, associated feeders and accessories, delivery, installation, setup, functional verification, and operator training. This capability will improve placement accuracy and repeatability, reduce manual assembly time, increase throughput, improve assembly consistency, and restore an in-house automated PCB assembly capability for current and future Code 675 hardware.
2. Characteristics, Scope, and Specs
LINE PART NO. DESCRIPTION QTY.
1 MC385V1V MC385V1V MidVolume Pick & Place
MC385V1V
Singlehead pick and place machine with welded steel frame construction Standard optics package with COGNEX on the fly vision alignment camera mounted on head and stationary, upward looking vision alignment camera, covering component range from 01005s to 100 x 150 mm.
High precision ball screw XY Drive Closed loop AC servo motor control High resolution rotary encoded XY drive mechanism 15position tool holder Reference camera for fiducial recognition and teaching Windows based advanced pick and place control software with standard component library, universal CAD conversion, Virtual PCB Simulator, Smart Feeder Optimization and more Computer controller with flatscreen LCD display, keyboard and mouse Network adapter Remote service support software.
2 FR32K 32Port Feeder Base for MC Series 1 3 TSCST0810 Cut strip holder Ten 8 mm lanes 2 4 KFTA3D8MMSW Tape Feeder with Built In Display for 8mm Tapes w/ Small
Window for Better Performance on 0201/0402 Components
5 KFTA3D8MM Tape Feeder with Built In Display for 8 mm Tapes, max.
3.3 mm Tape Thickness
6 KFTA3D12MM Tape Feeder with Built In Display for 12 mm Tapes, max. 7 mm Tape Thickness
7 KFTB10 Universal IC/Tube Feeder 10 Lanes 1 8 Install and Training Initial Day Install Initial Day
Install and training. Depending on location floor time may be deducted due to travel time.
9 Install and Training Consecutive Day Install Consecutive Day Installation and training consecutive day
The contractor shall provide the following equipment and services:
• One (1) MC385V1V Mid-Volume Pick & Place Machine
• One (1) FR32K 32-Port Feeder Base
• Two (2) TS-CST08-10 Cut Strip Holders
• Two (2) KFTA3D-8MM SW 8 mm Tape Feeders
• Fifteen (15) KFTA3D-8MM 8 mm Tape Feeders
• Four (4) KFTA3D-12MM 12 mm Tape Feeders
• One (1) KFTB-10 Universal IC/Tube Feeder
• One (1) Initial Installation and Training Day
• One (1) Consecutive Installation and Training Day
The MC385V1V shall include its standard vision alignment, fiducial recognition, CAD conversion/programming software, component library, feeder optimization, computer controller, display, and associated operating hardware.
During a single site visit, the contractor shall position, level, calibrate, configure, and check out the machine; install and configure the feeders and software; and demonstrate successful component placement. NASA shall route the required compressed-air supply prior to installation. Remote service access is not required.
The contractor shall provide on-site training to Chris Pirner covering machine operation, PCB programming/CAD import, component library creation, feeder setup, vision/fiducial setup, maintenance, troubleshooting, and normal operation. A separate formal Site Acceptance Test is not required; successful functional checkout and demonstration of component placement shall verify installation completion.
3. Place of Performance
Goddard Space Flight Center (GSFC)
4. Period of Performance
15 weeks ARO
The contractor shall coordinate delivery, installation, functional verification, and training with NASA GSFC Code 675. Installation and training shall occur during the same site visit. The complete system shall be delivered, installed, configured, functionally verified, demonstrated, and fully operational, with operator training completed, no later than November 18, 2026.