SATPC0042440 Tab 04 4 SOW..pdf

PDF 80 KB Posted

Attached to
PureAire 2026 Federal contract opportunity
Solicitation number
80NSSC26941778Q
Issued by
National Aeronautics and Space Administration Shared Services Center

About this file

This is a Statement of Work for the acquisition of Pure Aire oxygen (O2) monitoring equipment for NASA Langley Research Center. The contractor must supply hardware that is compatible and interchangeable with equipment currently in use at the facility.

The required equipment consists of four Pure Aire product lines with specified quantities: seven TX-1100-DRA O2 Digital Monitors (Model 99117) capable of monitoring oxygen levels from 0-25% with user-selectable audio alarms, relays, 4-20mA output, and remote sensors with 30-foot remote cables including US power supply; seven Horn & Strobe units in blue (Model 42004); seven Oxygen Remote Digital Displays (Model 99091) for 0-25% O2 measurement; and three 8-Channel Controllers with Touch Screen (Model 99233). All equipment must be shipped to NASA Langley Research Center in Hampton, Virginia 23681, with a required delivery leadtime of 30 days after receipt of order.

View the file

Other files for this federal contract opportunity

Other files attached to PureAire 2026, newest first.
File Type Posted
SATPC0042440 Tab 10 RFQ Open Market Template.pdf PDF
SATPC0042440 Tab 06 BNJ..pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

This requirement is for acquisition of Pure Aire O2 monitoring equipment. All hardware and shall be compatible and interchangeable with current hardware currently in use at NASA Langley Research center. Specific requirements are listed below.

2. Characteristics, Scope, and Specs

The contractor shall provide hardware with quantification and specifications equal to the requirements provided below.

QUANTITY

PART# - DESCRIPTION

Pure Aire Model Number: 99117 - TX-1100-DRA O2 Digital Monitor 0-25% w/userSelectable Audio Alarm, Relays & 4-20mA Output w/RemoteSensor. 30' Length Remote Cable * Includes US Power Supply

Pure Aire Model Number: 42004 - Horn & Strobe, Blue

Pure Aire Model Number: 99091 - Oxygen (O2) 0-25% Remote Digital Display

Pure Aire Model Number: 99233 8 Channel Controller with Touch Screen

3. Place of Performance

Shipping address:

NASA Langley Research Center Hampton, VA 23681

Final use location:

NASA Langley Research Center Hampton, VA, US, 23681

4. Leadtime for Delivery:

30 Days ARO