This is a Statement of Work for NASA Glenn Research Center's procurement of a JEOL NMR spectrometer system. NASA GRC requires the purchase of one JEOL JNM-ECZL400S 400 MHz, 9.4 Tesla NMR Spectrometer to support ongoing research in polymer synthesis, polymer aerogels, multifunctional composites, and other advanced materials initiatives supporting NASA's aerospace and aeronautics missions. The complete system includes nine components: the main spectrometer unit, a 9.4T shielded NMR magnet with 54mm bore, a pneumatic vibration damping table, a Dell Precision workstation with Windows 11 64-bit operating system (I5-13500 processor, 16GB memory, 1+ TB disk, 4GB graphics), a 400 MHz 5mm FG/RO digital auto-tune probe, a spinner housing, an auto-tuning unit, and an APC Smart-UPS SMX3000LV 3000VA uninterruptible power supply.
The place of performance is NASA Glenn Research Center located at 21000 Brookpark Road, Cleveland, Ohio 44135, with the point of contact being Stephanie Vivod in Building 49, Room 241. The period of performance is 5 to 7 months from award.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements The NASA Glenn Research Center (GRC) requires the purchase of JEOL JNM- ECZL400S 400 MHz, 9.4 T NMR Spectrometer. The instrument is required to support ongoing research in polymer synthesis, polymer aerogels, multifunctional composites, and other advanced materials supporting NASA aerospace and aeronautics missions.
2. Characteristics, Scope, and Specs
Quantity OEM Part # Product Description
1 JNM-ECZL400S JEOL JNM-ECZL400S 400 MHz, 9.4 T NMR Spectrometer
NM-
04890SCMYWSD NMR Magnet, 9.4T, Shielded, 54mm, Year Hold
NM-04620SB-K5-
4S Vibration Damping Table for 400 MHz Magnet, Pneumatic
1 NMR-WS-PC
Dell Precision Workstation / Windows 11 64-Bit, I5-13500, 16GB mem, 1+ TB Disk, 4GB graphics
NM-03812RO5S-
4S 400MHZ 5MM FG/RO DIGITAL AUTO TUNE PROBE
NM-
04920HOU4JY SPINNER HOUSING 400JJYH
1 NM-71190AT-4S AUTO TUNING UNIT
APC-
SMX3000LV
APC Smart-UPS SMX3000LV 3000VA Rack/Tower LCD
100-127V
3. Place of Performance NASA Glenn Research Center (GRC) POC: Stephanie Vivod; Building: 49; Room: 241 21000 Brookpark Road Cleveland, OH 44135
4. Period of Performance 5 – 7 Months ARO