SATPC0041290 Tab 04 4 SOW.pdf

PDF 117 KB Posted

Attached to
DetaClad Explosion Clad Metal made up of Ti6AL4v, Tantalum and Inconel X750
Solicitation number
80NSSC26934696Q
Issued by

About this file

This is a Statement of Work for the fabrication and delivery of explosion-clad material. The contractor must fabricate and ship one item measuring 17 feet by 14 inches of DETAClad Explosion Clad Material with a target minimum sound bond of 11 inches by 11 inches. The metal combination consists of Titanium B265 Grade 5 clad metal at 0.375 inches thickness, Tantalum B708 interlayer at 0.030 inches nominal thickness, and X-750 base metal at 0.395 inches thickness. The product must comply with clad product specifications B898 and DMC100, with certificates delivered via email PDF per DMC100 requirements.

Technical requirements include three uncut edges with one cut edge and standard surface treatment. Testing must include ultrasonic testing per ASTM B898 Class B and helium leak testing at a rate of 1 x 10(-8) scc/second. Stress relief heat treatment may be required per DMC100 Section 6.2.7. The clad metal serves for corrosion allowance only, and weld rework is permitted per DMC100 Section 11. Client review and approval of procedures, weld qualifications, non-destructive examinations, material test reports, and inspection and test plans may impact quoted price and delivery. Performance will be conducted at Noble Clad, 11800 Ridge Parkway, Suite 300, Broomfield, Colorado 80021, with processing in Mount Braddock, Pennsylvania. Final product delivery is required within 11-12 weeks.

View the file

Other files

File Type Posted
SATPC0041290 Tab 07 Capability Statement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

The Contractor shall fabricate and ship 1 item of 17’ x 14“ – DETAClad Explosion Clad Material Target minimum sound bond 11” x 11” with following

Interlayer; 708 .030” Nom

2. Characteristics, Scope, and Specs

Per DMC 100

3.Technical Requirements for All Items

- 3 Edges Uncut/ One edge Cut

- Cladding metal is for corrosion allowance only applicable.

3. Place of Performance

Noble Clad

4. Period of Performance final product in 11-

File details come from the government source that posted it. Updated .