SATPC0040622 Tab 04 4 SOW_Redacted.pdf
PDF 145 KB Posted
- Attached to
- Faraday Tent Enclosure Purchase Federal contract opportunity
- Solicitation number
- 80NSSC26928001Q
About this file
Statement of Work Summary
This Statement of Work details procurement requirements for RF shielding and filtering equipment to be delivered to NASA Johnson Space Center in Houston, Texas, within 8 weeks. The primary deliverable is two Faraday Defense 48"x46"x36" RF Tent Enclosures (Part No. 60102) constructed with dual-layer high-shielding Faraday CYBER Fabric certified to MIL STD 188-125 and IEEE 299-2006 standards. These enclosures block WiFi, Bluetooth, 5G, RFID, NFC, and radio signals from low MHz to 40GHz, feature stitched construction, adjustable Velcro tension straps, and a patented magnetic door system with heavy-duty vinyl flooring and black sports nylon exterior protection.
The procurement includes 10 additional line items supporting the RF enclosures: two ventilation systems with 120mm dual honeycomb vent panels and 204CFM airflow, two wall-mounted IO plates with 250VAC/500VDC/30A facility filters, two 6-terminal DC filters, six SMA female bulkhead connectors, two dual RJ-45 Ethernet-filtered interfaces, two dual HDMI 1.4 interface filters, two dual USB 3.0 HP filters, four BNC RF bulkheads for SDI cameras, four JRE UFI-1 universal interface HP filters, and four blank wall-mounted removable plates with leg extenders. The work will be performed at NASA Johnson Space Center, 2101 E. NASA Parkway, Houston, TX 77058, with completion required 8 weeks after order release.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SATPC0040622 Tab 07 Capability Statement FBO Posting.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements
The information listed below is required to complete this purchase.
2. Characteristics, Scope, and Specs
LINE PART NO. DESCRIPTION QTY.
1 60102 Faraday Defense 48”x46”x36” RF Tent Enclosure
• Constructed with two layers of high-shielding Faraday CYBER
Fabric (Nickel, Copper, Silver) and lab tested and certified to shield effectiveness standards MIL STD 188-125 and IEEE 299-
• Blocks and isolates WiFi (2.4 & 5GHz), Bluetooth, cell signals including 5G networks, RFID, NFC, and radio signals from low
MHz to 40GHz
• Stitched construction to reduce tears (compared to non-stitch enclosures)
• Adjustable Velcro tension straps for precise tent tightness and positioning within the frame
• Patented magnetic door system with a magnetic door frame for a tight RF seal
• Heavy duty vinyl floor, extenral outer layer of Black Sports
Nylon for extra protection of Farady CYBER Fabric
• Internal Faraday Tent Dimensions: 48" x 36" x 36"
• External Frame Dimensions: 54" L x 39" W x 39" H
2 60124 Ventilation system for tabletop enclosure with (2) 120mm x 120mm dual honeycomb vent panels. Includes (1) 120mm 12VDC muffin fan with 90-240VAC/12VDC power supply with US plug (US plug clip can be changed for international operation) Air flow: 204CFM
3 60138 Wall mounted high performance IO plate. Includes
250VAC/500VDC/30A facility filter (-100 dB 100Hz to 40GHz) w/
(1) USA 120VAC/15 5 outlet power strips rated for mac 15A and a
5-15P 120V/15A line cord
4 60148 6 Terminal DC Filter 2
5 60145 SMA Female Bulkhead w/Dust Cap 6
6 60160 Dual Rj-45 Ethernet-Filtered 2
7 60168 Dual HDMI 1.4 Interface Filer 2
8 60159 Dual UBS 3.0 HP Filter 2
9 60164 (1) 75 Ohm BNC RF Bulkhead for SDI Camera and (1) 50 Ohm
BNC RD Bulkhead
10 60154 JRE UFI-1 Universal Interface HP Filter for the thermocouple and digital/analog IO test
11 60139 Blank wall-mounted removable plate with leg extenders 4
3. Place of Performance
NASA Johnson Space Center
2101 E. NASA Pkwy
Houston, TX 77058
4. Period of Performance
8 weeks ARO
File details come from the government source that posted it. Updated .