About this file
This document details technical specifications for various electronic components, including a Multiplexer (MUX), Precision Current Source, Adjustable Voltage Regulator, and Operational Amplifier. The components are designed for high-reliability applications, with key specifications including:
Shared technical requirements across all components include total dose hardness of 50 Krads (Si) or higher, Single Event Effect (SEE) resistance > 75 MeV cm2/mg, and an operating temperature range of -55°C to +125°C. Specific component details include: MUX features on-resistance <400 Ohms, transition time <500ns, and single/bipolar supply operation; Precision Current Source provides 100uA current with 3V to 40V operating voltage; Adjustable Voltage Regulator offers input voltage range of 4.25V to 40V and output voltage range of 1.25V to 37V; and Operational Amplifiers support dual/quad configurations with gain bandwidth >10MHz, single/dual supply range of 2.7V to 40V, and typical CMRR and PSRR > 100 dB.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MUX
• Total dose hardness 50 Krads (Si) or higher for both high (50-300rad(Si)/s) and low dose rate (0.01rad(Si)/s)
• SEE > 75 MeV cm2/mg
• On-resistance, <400 Ohms max
• Transition time, <500ns
• On-resistance match, <10 Ohms
• NO-Off leakage current, <20pA at 25°C
• 1.5pC charge injection
• Single-supply operation (4.5V to 30V)
• Bipolar-supply operation (±4.5V to ±20V)
• Rail-to-rail signal handling
• TTL/CMOS-logic compatible
Precision Current Source dose rate (0.01rad(Si)/s)
• SEE > 75 MeV cm2/mg
• Current = 100uA
• Operating voltage range: 3V to 40V
• Operating temperature range: -55°C to +125°C
• High initial accuracy < ±0.34%
Adjustable Voltage Regulator dose rate (0.01rad(Si)/s)
• SEE > 75 MeV cm2/mg
• Current = 100uA
• Input voltage range: 4.25V to 40V
• Output voltage range: 1.25V to 37V
• Output shall be adjustable
• Operating temperature range: -55°C to +125°C
• High initial accuracy < ±0.34%
Operational Amplifier dose rate (0.01rad(Si)/s)
• SEE > 75 MeV cm2/mg
• Slew rate > 10V/us
• Dual or quad operational amplifiers
• Single and dual supply range: 2.7V to 40V
• Gain bandwidth > 10Mhz
• Typical CMRR > 100 dB
• Typical PSRR > 100 dB