SATPC0037657 Tab 04 4 SOW.pdf

PDF 70 KB Posted

Attached to
100ohm diff 26AWG wire; qty 2, 500
Solicitation number
80NSSC25896071
Issued by

About this file

This document is a detailed specification sheet for wire procurement, outlining precise technical requirements for a specialized signal transmission wire. The specifications include critical parameters such as a signal transmission speed of ≥1GHz, a standard impedance of 100 +/- 10 ohms, and a 26AWG conductor gauge made of silver-plated copper or copper alloy. The wire must have blue/white color coding, a white FEP jacket, expanded PTFE dielectric material, and a shield with ≥90% coverage and no drain wire.

The procurement requires 2,500 feet of wire with an uninterrupted length greater than 1,000 feet, capable of operating in a temperature range from -55C to 200C, and with a diameter ≤0.1 inch. The wire must comply with ANSI/NEMA WC 27500 and SAE AS4373 standards, and can only be distributed by an authorized reseller or the original manufacturer. These stringent specifications suggest the wire is likely for a specialized, high-performance application, potentially in aerospace or advanced technological environments.

View the file

Other files

File Type Posted
SATPC0037657 Tab 07 Capability Statement SAM.gov.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifica�ons for Wire Procurement:

Signal Transmission Speed: >= 1GHz

Standard Impedance: 100 +/- 10 ohms

Conductor Gauge: 26AWG

Conductor Material: Silver-Plated Copper or Silver-Plated Copper Alloy

Conductor Color Coding: Blue / White

Capacitance: < 15 pF per foot

Dielectric Withstanding Voltage: >= 1000 Vrms

Jacket Material: FEP

Jacket Color: White

Shield: >= 90% coverage, no drain wire

Dielectric Material: Expanded PTFE / PTFE

Temperature Range (minimum span): -55C to 200C

Diameter: <= 0.1 inch nominal diameter

Qty: 2500�, uninterrupted length > 1000 � (last 500� length ok)

Standards Compliance:

ANSI/NEMA WC 27500 for Environmental Tes�ng, Jacket and Marking

SAE AS4373: Test Methods for Insulated Electric Wire

Distributer Requirements:

Must be an authorized reseller or the original manufacturer.