SATPC0033804 Tab 04 4 SOW_Redacted.pdf
PDF 204 KB Posted
- Attached to
- Repair of Cobham Equipment
- Solicitation number
- 80NSSC24856712Q
About this file
This statement of work outlines the repair requirements for two pieces of equipment. The first item is a HPA 7450 with part number 802-10-0013 and serial number P200016 that requires replacement of its packaging kit, PCB assembly, and repair of paint damage, along with cleaning. The second item is an SDU with part number 802-10-0005-004 and serial number P200001 that needs replacement of its packaging kit and PCB assembly, repair of wear on its enclosure lid, and cleaning. Repairs are to be completed within 8 weeks of order date, with delivery by February 2024. Estimates for the repair costs of each item are attached. The related federal contract opportunity is solicitation number 80NSSC24856712Q for the repair of Cobham equipment issued by the National Aeronautics and Space Administration Shared Services Center.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SATPC0033804 Tab 07 Capability Statement SAM.gov Posting Commerical.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Repair SOW
Statement of Work Statement of Work and Description for
Repair of 1 HPA 7450 and 1 SDU
1. Objective/Requirements
Repair of 1 HPA 7450 and 1 SDU
2. Characteristics, Scope, and Specs
HPA 7450 PN 802-10-0013 SN: P200016:
PACKAGING KIT INCDB BOX LID & TRAY INT,
PACKAGING FOAM ARINC MCU TOP & PACKAGING
FOAM ARINC MCU
BOTTOM HAVE MATERIAL DAMAGES; TO BE
REPLACED. PCB ASSY SBB RFB HAS ELECTRICAL
FAILURE; TO BE
REPLACED. HIGH POWER AMPLIFIER HAS PAINT
DAMAGE; TO BE REPAIRED. UNIT TO BE CLEANED.
SDU P/N: 802-10-0005-004 S/N: P200001:
ARINC GENERIC ENCLOSURE LID HAS FAIR WEAR
& TEAR; TO BE REPAIRED. PACKAGING KIT IN CDB
BOX LID
&TRAY INT, ACKAGING FOAM ARINC MCU TOP &
ACKAGING FOAM ARINC MCU BOTTOM CANNOT
BE REUSE; TO BE REPLACED. PCB ASSY SWIFTBB
SDU ACM HAS ELECTRICAL FAILURE; TO BE
REPLACED. UNIT TO BE CLEANED.
3. Place of Performance
4. Period of Performance
ARO from the order effective date of 8 weeks. Delivery is requested no later than February 2024.
Market Research
PSC Code J016 and NAICS Code 334290
IGCE Please see attached estimate for P/N: 802-10-0005-004 S/N: P200001