This file contains a statement of work for a thermal air system. The statement of work specifies requirements for a forced air thermal system capable of temperature performance between 80C to 225C at 50/60Hz power supply of 185-250VAC and 30A typical. The system must be able to transition temperatures between 55C to 125C and 125C to 55C at a rate of 55C.
The related federal contract opportunity is solicitation number 80NSSC23833862Q from the National Aeronautics and Space Administration Shared Services Center for a thermal air system.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification for Forced Air Thermal System
Temperature Performance & Airflow Capacity
Temperature Range ‐80°C to +225°C (50/60Hz same system)
Power Supply 185‐250 VAC, 30 A
Typical Temperature Transition Rate
‐55°C to +125°C / +125°C to ‐55°C <10 sec
Temperature Accuracy ± 1.0°C (calibrated system)
Temperature Resolution ± 0.1°C
Temperature Air Output System
30 SCFM@85‐110 PSI (for 24 SCFM output)
Temperature Control Methods Environmental Internal Air TC and Remote External Type T, K, RTD (TC Sensors)
Facility Requirements / Dimensions & Weights / Compressed Air
Dimension Not to exceed: W=60 cm, H=140 cm, D=95 cm
Weight (Unpacked) Not to exceed 270 kg
Misc Portable on swivel rollers