This file contains a statement of work for a thermal air system. The statement of work specifies requirements for a forced air thermal system capable of temperature performance between 80C to 225C at 50/60Hz power supply of 185-250VAC and 30A typical. The system must be able to transition temperatures between 55C to 125C and 125C to 55C at a rate of 55C.

The related federal contract opportunity is solicitation number 80NSSC23833862Q from the National Aeronautics and Space Administration Shared Services Center for a thermal air system.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specification for Forced Air Thermal System

Temperature Performance & Airflow Capacity

Temperature Range ‐80°C to +225°C (50/60Hz same system)

Power Supply 185‐250 VAC, 30 A

Typical Temperature Transition Rate

‐55°C to +125°C / +125°C to ‐55°C <10 sec

Temperature Accuracy ± 1.0°C (calibrated system)

Temperature Resolution ± 0.1°C

Temperature Air Output System

30 SCFM@85‐110 PSI (for 24 SCFM output)

Temperature Control Methods Environmental Internal Air TC and Remote External Type T, K, RTD (TC Sensors)

Facility Requirements / Dimensions & Weights / Compressed Air

Dimension Not to exceed: W=60 cm, H=140 cm, D=95 cm

Weight (Unpacked) Not to exceed 270 kg

Misc Portable on swivel rollers