This technical specification and statement of work outline requirements for a Department of the Navy data storage area network (SAN) procurement. The Navy seeks to acquire two SAN storage controller units with Intel Xeon processors, 256GB RAM, and Windows Server 2016; one 5.5PB pool of JBOD storage enclosures with 14TB HDDs; two 42U server racks; four rack PDUs; and two KVMs. The specification also includes ten spare 14TB HDDs. Responses were requested by April 13, 2020 to Kevin O'Shaughnessy for the Naval Surface Warfare Center Philadelphia Division contract NSWCPD_DAS_SAN.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAS SAN
Detailed Specifications/Requirements
Item 0001 DAS Integrated Storage System Quantity: 02
Subject procurement is for a complete Storage Area Network minimally composed of the following sub-items. The system as a whole must include:
1. Commercial warranty
2. Commercial technical support via phone and/or email.
3. Notional design as Figure 1.
Figure 1 (Notional Design)
Continued on next page…
Item 0001.1 DAS SAN Storage Controller Unit Quantity: 02
Industrial 2U, 19 inch rack mount computer system with the following specifications:
1. Industrial 2U, 19 inch rack mount chassis.
2. 720 watt hot-swappable redundant internal power supply.
3. Chassis must only be cooled from front and back. Top and bottom may not contain cooling vents.
4. Must operate in the temperature range of 32 DEGF to 104 DEGF.
5. Must include dual Intel Xeon Silver 4210 Processor with 13.75MB cache and 2.20GHz, or equivalent.
6. Must include 256GB, DDR4 ECC RAM.
7. Must contain two Ethernet controllers of at least 10Gbps, either integrated on the motherboard or as a separate PCIe expansion card.
8. Must include two (2) 512 GB Enterprise rated SSD or NVMe mirrored (RAID 1) configured as the boot drive.
9. Must include Windows Server 2016 Datacenter Edition, 64 bit, with 20-core license
a. Servers in each unit will be configured in cluster mode
10. All hardware shall be Microsoft Windows 2016 Datacenter Edition compatible.
11. Hard drives must be installed in a slide-out chassis easily accessible from the front of the computer.
12. All required system driver software must be included on a CD/DVD containing current drivers for Microsoft Windows 2016 Datacenter Edition.
13. Must include an 8X DVD/CD ROM drive that color matches the chassis.
14. Must include one USB port accessible from the front of the chassis.
15. Video output, onboard or via installed video adaptor card, must support 1280x1024 resolution.
16. Trusted Platform Module (TPM) v. 2.0 must be installed
17. Must include all necessary slide rail hardware for mounting in a 19 inch rack 48” deep with square hole configuration.
18. Must include dual RAID controller/engine, either integrated or as an external component
a. Controllers must be redundant and support active-active configuration and high-availability
b. Must support 12GB/s
c. Must have 1Gb cache
d. Must include Zero Maintenance Flash Cache protection
e. Must include Battery Backup Unit
f. Must support RAIDs 0,1,10,3,5,6,20,50,60,single-disk,or JBOD mode
g. RAID subsystem via external RAID engine is acceptable
19. Must include power cables compatible with ITEM 0003
Item 0001.2 DAS SAN Storage JBODS Quantity: 1 raw storage pool of 5.5 PB
Industrial 4U, 19 inch rack mount JBODs with the following specifications:
1. Industrial 4U, 19 inch rack mount chassis.
2. Dual hot-swappable 1400 watt redundant power supplies.
3. Must include hot swappable cooling fans.
4. Chassis must only be cooled from front and back. Top and bottom may not contain cooling vents.
5. Must operate in the temperature range of 32 DEGF to 104 DEGF.
6. Must include swappable dual-controllers/IO modules to support high-availability
7. Must contain 4 6Gb/s SAS/mini-SAS ports per unit
8. Must support standard RAID levels (0,1,5,6,10,50,60)
9. Must include 4 mini-SAS HD ports per module
10. Must not exceed 6 JBODs and have a total raw storage capacity of not less than 5.5PB.
11. Installed drives must be Enterprise Class SAS or SATA drives with following specifications:
a. Storage: 14TB
b. Speed: 12Gb/s
c. RPM: 7200
12. Must include power cables compatible with ITEM 0003
Item 0002 Rack to contain ITEM 0001 Quantity: 02
Server Grade Standard U Equipment Mounting Rack meeting the following specifications:
1. Rack must dimensionally and color match APC NetShelter SX 42U AR3300
2. Rack outer dimensions not to exceed 80”x24”x48” (H x W x D)
3. Rack must include removable side panels on both right and left sides
4. Rack must include REMOVABLE front AND rear hinged door panels.
a. Panels must vented.
b. Front panel must be lockable
5. Rack must have a usable inside height of 42U.
6. Rack must have a usable inside depth of at least 40”.
7. Rack must have a usable inside width of 19” for rack-mount hardware.
8. Rack must be black.
9. Rack must have 2 front and 2 rear rails.
a. Rails must be adjustable, front to back.
b. Rails must be tapped with SQUARE holes for quick-connect computer rails (see Figure 2).
Figure 2 – Rail Mounting Holes
Item 0003 DAS Room Rack Power Distribution Unit (PDU) Quantity: 04
Rack PDU meeting the following specifications:
1. PDU must be rack mountable
2. Input Voltage must be 220V via a NEMA L6-30P 10ft cord
3. Maximum current draw must be 30A
4. Must provide 24 NEMA 5-20R receptacles
5. Must meet cUL Listed, CSA C22.2 No. 60950-1-03, UL 60950-1, UL Listed
Item 0004 DAS Room Rack Mount KVMs Quantity: 02
Standard 17” screen rackmount KVM meeting the following specifications:
1. Must have resolution of 1280x1024
2. Must support 8 computers
3. Must include 8 6ft USB cable kits
4. Must include power cables compatible with ITEM 0003
Item 0005 DAS SAN Spare HDDs Quantity: 10
Identical HDDs used in Item 0001.2.10 image1.emf