SALIENT REQUIREMENTS.pdf
PDF 260 KB Posted
- Attached to
- CONEX BOX
- Solicitation number
- SPMYM226Q7738
About this file
This document is a Salient Requirements specification for a Custom 20ft Mobile Workshop Container. The container must be a 20-foot new standard one-trip ISO container with standard dimensions of 20' L x 8' W x 8'6" H in beige exterior color, equipped with forklift pockets and an ISO lockbox to maintain structural integrity for frequent mobile deployment and transit. Access includes standard double cargo doors on one end and one 3-foot by 6-foot 8-inch steel personnel man-door with left-hand outswing, double bore, locking lever, and deadbolt.
The interior must feature closed-cell spray foam insulation on walls and ceiling with 2-inch by 3-inch steel stud framing and 1/2-inch HDPE paneling. The electrical package includes a 125-amp, 4-space, 8-circuit breaker panel, an exterior weatherproof shore-power hookup with twist-lock receptacle, two 4-foot LED shop light fixtures, and a minimum of three C1D1-rated wall receptacles, with provisions for future circuit expansion. Climate control requires a minimum 12,000 BTU mini-split air conditioner with inverter heat pump and heavy-duty security cage or steel bars protecting all external HVAC components. Workspace includes one 72-inch by 30-inch modular workbench with integrated cabinets, butcher block work top, and 5,000-pound capacity. Delivery must be via tilt-bed ground delivery with all penetrations sealed and watertight.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - SPMYM226Q77380002.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHIPPING CONTAINER SALIENT REQUIREMENTS
Custom 20ft Mobile Workshop Container
1) Base Container & Structural Integrity
a) Description: 20ft New Standard One-Trip ISO Container.
b) Dimensions: 20’ L x 8’ W x 8’6” H (Standard ISO height).
c) Exterior Color: Biege
d) Condition: "One-Trip" / New Build with Forklift Pockets and an ISO Lockbox. Must maintain structural integrity for frequent mobile deployment and transit.
e) Access Points: Standard double cargo doors on one end.
f) Side Door: (1) 3ft x 6ft 8in Steel Personnel Man-Door (Left Hand Outswing, Double Bore with Locking Lever & Deadbolt).
2) Insulation & Interior Paneling
a) Insulation: Closed-cell spray foam insulation on walls and ceiling.
b) Framing: 2 in. x 3 in. Steel Studs.
c) Paneling: Interior walls finished with durable 1/2 in. HDPE (High-Density Polyethylene)
Sheets
3) Electrical Package
a) Load Center: 125 Amp, 4 Space, 8 Circuit electrical breaker panel.
b) Input Hookup: Exterior weatherproof shore-power hookup (twist-lock receptacle).
c) Lighting: Two (2) 4ft LED shop light fixtures.
d) Receptacles: A minimum of three (3) C1D1-rated wall receptacles.
e) Note: The electrical package must be expandable to accommodate additional circuits if required
4) Climate Control (HVAC)
a) System: Minimum of 12,000 BTU Mini-Split Air Conditioner with Inverter Heat Pump.
b) Capacity: Minimum of 12,000 BTU cooling and heating capability.
c) Protection: Must include a heavy-duty security cage or steel bars installed over all external HVAC components to prevent damage during transit.
5) Workspace & Storage (Deployable Standard)
a) Workbench & Storage: One (1) 72 in. x 30 in. Modular Workbench with integrated cabinets.
b) Work Surface: Butcher Block Work Top
c) Capacity: 5,000 lb. capacity.
6) DELIVERY REQUIREMENTS
a) Method: Tilt-Bed Ground Delivery.
b) All Penetrations to be sealed and watertight
File details come from the government source that posted it. Updated .