The document is a Salient Characteristics specification for Pressure Washers, detailing requirements for five (5) commercial cold pressure washers for the Defense Logistics Agency Land and Maritime. The pressure washers must be 4 GPM at 4,000 PSI, constructed for outdoor use, with specific technical specifications including 460 Volt 3 Phase power, 14 Amps, a stainless steel frame, two-wheel upright cart design, and compact dimensions of 19 1/2" W x 28 1/2" L x 45" H.
The solicitation (SPMYM225Q2285) requires NRTL safety certification and compliance with OSHA regulations, specifically CFR Title 29, Part 1910. Key submission requirements include providing a CAGE code, manufacturer information, country of origin, lead time, and electronic submission through SAM.gov. The pressure washers must include standard features such as a galvanized frame, ceramic plunger pump, stainless steel control panel, external unloader mount, heavy-duty rotary switch, shut-off gun with wand, 15-degree nozzle, pneumatic wheels, pressure gauge, 15 ft power cord, and pump oil drain hose. Delivery destination is specified as Silverdale, WA.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM225Q2285.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics for Pressure Washers (Qty 5) May 27, 2025, 2025
Pressure Washer Specifications 4 GPM at 4,000 PSI Cold Pressure Washer – constructed for outdoor use 460 Volt 3 Phase 14 Amps Stainless Steel Frame Two Wheel Upright Cart Motor is NRTL Approved Smaller frame is needed to fit in small areas 19 1/2 W x 28 1/2" L x 45” H
Standard Features Available Options Galvanized Frame Belt Drive Ceramic Plunger Pump Stainless Steel Control Panel External Unloader Mount Heavy Duty Rotary Switch Shut Off Gun with Wand 15 Degree Nozzle Pneumatic Wheels Pressure Gauge 15 ft Power Cord Pump Oil Drain Hose
NRTL Safety Certification Requirements - Equipment will be incompliance with the applicable Code of Federal Regulations (CFR) Title 29, Part 1910. Any equipment will be deemed acceptable and approved by TRF, Bangor, if it meets specific Occupational Safety and Health Administration (OSHA) conditions outlined in CFR Title 29, Part 1910; Subparts "O" and "S". Specifically, the equipment will be "Accepted" by TRF, Bangor, if it has been inspected and found by a Nationally Recognized Testing Laboratory (NRTL) to conform to specified plans or procedures of applicable codes. The equipment (as a whole system) shall be Nationally Recognized Testing Laboratory (NRTL) inspected and certified (by an OSHA authorized third party). sticker documentation mounted on the equipment, (which acknowledges it is NRTL certified), shall be provided.