This document is a specification of eddy current probes and related components required for federal contract opportunities JML 61596930-39 and 61606930.

The procurement specifies 11 distinct eddy current probe models with varying specifications for conducting bobbin and array inspection on condenser tubing. All probes must feature a 36-pin Amphenol connector and be compatible with the existing Eddy Current Acquisition System. The required probes include: one CXB4-024 straight section array bobbin probe (0.490" diameter), one XP12-005 flexible model array bobbin probe (0.480" diameter), two CXB4-012 straight section probes (0.570" diameter), one XP12-012 flexible model probe (0.560" diameter), one CXB6-001 mag biased array probe (0.490" diameter), one CXB6-006 mag biased array probe (0.570" diameter), one CXB4-032 straight section probe (0.480" diameter), one CXB6-008 mag biased probe (0.480" diameter), and six CXB4RPF-001 straight section array bobbin probes (0.490" diameter). Additionally, the procurement requires 30 replaceable centering feet kits (RPFCXB-001) and 12 replaceable feet captivation screws (P/N 70002884). All probes are 50 feet in length with Poly Type 3/8T cable configuration. The manufacturer must perform quality verification checks on each probe to ensure proper operational capability.

View the file

Other files

File Type Posted
26Q0108 PROBE EDDY CURRENT.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Eddy Current Probes Salients

JML 61596930-39 and 61606930

The probes listed below will be utilized to perform eddy current bobbin and array inspection on condenser tubing. Manufacturer shall ensure a manufacturing quality check is performed on each probe to ensure proper operation. All probes will have a 36 pin Amphenol connector and be capable of being detected and identified by the existing Eddy Current Acquisition System.

1 each P/N CXB4-024 – Straight Section CXB4 Array Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.490”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Mid Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N XP12-005 – Flexible Model XP12 Array Bobbin Probe, Diameter: 0.480”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Mid Frequency Bobbin; Poly Type 3/8T, Length: 50’

2 each P/N CXB4-012 – Straight Section CXB4 Array Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.570”, used to inspect tube ID of 0.620”, Coil: 2x16 Array/Low Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N XP12-012 – Flexible Model XP12 Array Bobbin Probe, Diameter: 0.560”, used to inspect tube ID of 0.620”, Coil: 2x16 Array/Low Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N CXB6-001 - Straight Section CXB6 Mag Biased Array and Mag Biased Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.490”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Low Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N CXB6-006 - Straight Section CXB6 Mag Biased Array and Mag Biased Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.570”, used to inspect tube ID of 0.620”, Coil: 2x16 Array/Low Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N CXB4-032 – Straight Section CXB4 Array Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.480”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Mid Frequency Bobbin; Poly Type 3/8T, Length: 50’

1 each P/N CXB6-008 - Straight Section CXB6 Mag Biased Array and Mag Biased Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.480”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Mid Frequency Bobbin; Poly Type 3/8T, Length: 50’

6 each P/N CXB4RPF-001 – Straight Section CXB4/RPF Array Bobbin Probe, Titanium Sleeve and Centering Feet, Diameter: 0.490”, used to inspect tube ID of 0.527”, Coil: 2x14 Array/Low Frequency Bobbin; Poly Type 3/8T, Length: 50’

30 each P/N RPFCXB-001 – replaceable centering feet kit for CXB2/RPF, CXB4/RPF or CXB6/RPF Probes, Diameter: 0.490”, used to inspect tube ID 0.527”

12 each P/N 70002884 - Replaceable feet captivation screw for CXB4 probes used in a 0.527" ID tube

File details come from the government source that posted it. Updated .