This document is a memorandum from the 823rd Red Horse Squadron of the U.S. Air Force that provides the specifications for an external spot vibrator and clamps required for concrete applications. The key performance specifications include an integrated converter, small and compact design, asynchronous motor with stable speed, and suitability for cast-in-place jobsite or light precast concrete applications. The electrical output details cover the nominal current, voltage, frequency, and power. The mechanical output details cover the centrifugal force, vibrations, and dimensions. The document also specifies the environmental protection class, degree of protection, and electrical system features such as a breaker switch, operating indicator, and integrated transformer. This requirement is associated with a solicitation (FA441724Q0273) issued by the Department of the Air Force Special Operations Command for an "External Concrete Vibrator."
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CLSExport_FA441724Q0273 solicitation.pdf | ||
| RFQ - External Concrete Vibrators.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
823RD RED HORSE SQUADRON
25 July 2024
MEMORANDUM FOR RECORD
FROM: 823 RHS
USAF
633 Independence Rd.
Hurlburt Field FL, 32544
SUBJECT: External spot vibrator and clamps
References: (a) N/A
1. Below are the specifications for the requirement of external spot vibrator and clamps that must be met or exceeded in terms of performance and capability:
2. Performance Specs:
a. Integrated Converter
b. Small, Compact and light
c. Asynchronous motor with stable speed
d. Designed for cast in place jobsite applications or light precast concrete applications.
e. Clamp must offer superior fastening for steel formwork.
3. Electrical – Output Details:
a. Nominal Current: 3.00 A
b. Nominal Voltage: 110.0 – 130.0V
c. Nominal Frequency: 50.0-60.0 Hz
d. Nominal Power [P]: .28KW
4. Mechanical – Output Details
a. Centrifugal Force 517 ibf
b. Vibrations 6,0000.0 1/min
c. Vibrations (Hz): 100.0 Hz
d. Centrifugal force max. 780.09 ibf
5. Mechanical Details:
a. Length: 8.8”
b. Width: 7.5”
c. Height 4.0”
d. Weight: 25.66 lb.
e. Unbalanced mass/side pos1 6.0
f. Unbalanced mass/side pos2 2.0
6. Environment Data:
a. Protection class I/Protective earthing
b. Degree of protection IP66
7. Electrical System:
a. Breaker Switch On/Off: Yes
b. Operating indicator: Yes
c. Adjusting Frequency: No
d. Integrated Transformer: Yes
e. Length Cable: 49.2 Foot
f. King of plug: NEMA 5-15P-14W47
8. For any questions or concerns regarding these requirements, please contact the undersigned at brandon.bridges@us.af.mil or at 850-881-2153.
Digitally signed by
BRIDGES.BRANDON.LEE.129023
N.LEE.1290234014 4014
Date: 2024.07.25 12:28:34 -05'00'
BRANDON L. BRIDGES, MSGT, USAF