Salient Characteristics - VM Pilot Unit UTC Mobile Workshop.pdf
PDF 103 KB Posted
- Attached to
- VM Pilot Unit Mobile Workshop
- Solicitation number
- FA480324QB054
About this file
This document describes the salient characteristics for an expandable deployment workshop that is being procured by the Department of the Air Force Air Combat Command. The workshop must be configured to fit within the military's 463L cargo management system, allowing it to be secured into a military cargo aircraft roller and rail system. It must also have tie-down and sling points to permit transport by truck and helicopter.
The workshop must expand by 300%, with panels that fold down to create a workspace over 240 inches wide. It must have a divider to create two separate workspaces, as well as electrical, compressed air, and lighting capabilities. All access points must be securable with a durable, military-grade locking system. The opportunity is a pre-solicitation for a VM Pilot Unit Mobile Workshop, with the solicitation number FA480324QB054.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Source Sought Statement_24QB054 VM Pilot Unit UTC Mobile Workshop.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
FOR
EXPANDABLE DEPLOYMENT WORKSHOP
Airlift Worthiness
Expandable workshop must be configured to fit within the military’s 463L cargo management system.
Specifically, it must have the size and fixtures that allow it to be secured into a military cargo aircraft roller and rail system. It must also be equipped with tie-down and sling points that will permit transport by truck and by helicopter sling movement.
Accessibility
The expandable workshop must be configured with panels, hinged and the bottom, that when opened expand the working area of the workshop an additional 300%. Specifically, each of the two 88” (463L system) sides must fold down, allowing a workspace that more than 240 inches. Unit must be configured with one divider (approx. 108”) to create two separate workspaces and provide mounting points for electrical fixtures, compressed air plumbing and fittings, as well as lighting. Unit must be configured with a cover over each side, covering all sides, when the shelter is expanded.
Security
All access openings and drop panels must be securable with a durable, military-grade latch and locking system.
Electrical Power
The expandable workshop must be configured with suitable electrical connections and power management equipment to permit 110/220-volt single phase power. Unit must have suitable connections for external power supply from surrounding military bare base or commercial power grid as well as internal connections for an internal generator with sufficient cable length to operate the generator a safe distance from the workshop. Unit must have a suitable load/circuit breaker panel in addition to conduit and receptacles to connect to tool and equipment.
Compressed Air Capability
The expandable workshop must be configured with compact, scroll type air compressor capable of approximately 8 cubic feet per minute at 100 PSI. System must include a separate air receiver/storage tank, 20 gallons minimum. System must provide plumbing and fittings to both side of the shelter.
Lighting
The expandable workshop must be configured with LED lighting in each side of the workshop sufficient to safely light the work area.