Salient Characteristics (Temp Chamber).doc
DOC document 77 KB Posted
- Solicitation number
- W911QX23Q0183
About this file
This document outlines the requirements for one portable temperature conditioning unit. The unit must be capable of conditioning temperatures from -65C to 75C within 2C of the selected temperature. It must operate intrinsically safely for contents with autoignition temperatures over 230C. The unit must run on 120V AC power not exceeding 20 amps. Minimum internal dimensions are specified as 16" wide, 10" deep, and 10" high. It must fit through a 28" wide by 80" high doorway during operation. The related federal contract opportunity is solicitation number W911QX23Q0183 from the Department of the Army Materiel Command Army Contracting Command at Aberdeen Proving Ground to procure one temperature conditioning box for gun propellant and ammunition cartridges.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Provisions and Clauses Full-Text Attachment (for Combo Synopsis-Solicitation) (Temp Chamber).doc | DOC document | |
| Combination Synopsis-Solicitation for Commercial Purchases (Under SAT) (Temp Chamber).docx | DOCX document | |
| Evaluation Criteria (Comparative) (Stylus Pro).docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): Joseph W. Colburn Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR) The contractor shall provide one (1) Portable Temperature Conditioning Unit meeting the following specifications:
· Temperature Conditioning Range: -65°C to 75°C and +- 2°C after reaching selected conditioning temperature.
· Intrinsically Safe Operation for contents with autoignition temperature over 230 °C .
· Power shall be 120 Volts, alternating current (VAC), 60 Hertz (Hz) and not to exceed 20 amperes (Amps).
· Minimum conditioning volume dimensions: 16” wide, 10” deep, 10” high.
· Shall fit through 28” wide x 80” high doorway while in an operating orientation.
Contracting Officer:
Template last updated 07/28/2016
File details come from the government source that posted it. Updated .