The document is a Salient Characteristics Sheet for a Plasma Corrosion Mitigation System, detailing technical specifications for a specialized surface treatment technology. The system utilizes atmospheric pressure, non-thermal plasma to modify surface properties, capable of removing organic contaminants and activating surfaces for improved adhesion across various materials including metals, polymers, and composites. Key features include a dry, chemical-free process that is environmentally friendly, portable design (maximum dimensions 12" x 14" x 22" and weight of 41 lbs), and compliance with safety standards.
The related federal contract opportunity is solicitation FA462625Q0054 issued by the Department of the Air Force Global Strike Command, seeking a Plasma Corrosion Mitigation System that meets the specified salient characteristics. The system must be a brand-name or equal product, with specific requirements including a hand-held plasma pen with 20-foot cable, operating at sound levels no higher than 90 dBa, temperatures under 115 degrees, and input power of 208-240 VAC single-phase. The technology is designed for industrial environments, with applications in tight spaces and remote locations like shipyards, depots, and flightlines, offering precise surface treatment with minimal consumables and low operating costs.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation - FA462625Q0054.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics: Plasma Corrosion Mitigation System
1. Surface Treatment Mechanism
· Utilizes atmospheric pressure, non-thermal plasma to modify surface properties.
· Capable of removing organic contaminants (e.g., oils, greases, paints) and activating surfaces for improved adhesion.
2. Non-Thermal / Low-Heat Input
· Employs non-thermal or low-temperature plasma processes to avoid thermal damage to underlying substrates.
3. Material Compatibility
· Suitable for use on a broad range of materials including metals (steel, aluminum, titanium), polymers, and composites.
· Does not degrade substrates or leave residues.
4. Coating and Oxide Removal
· Capable of removing light oxides, coatings (e.g., primers, sealants, light paints), and corrosion products.
· Effective for prebonding or pre-welding applications.
5. Surface Activation
· Modifies surface energy to improve bonding, painting, welding, or coating adhesion.
· Achieves a uniform treatment area.
6. Dry, Chemical-Free Process
· No need for solvents, acids, or abrasive media.
· Environmentally friendly and compliant with green manufacturing directives.
7. Precision and Controllability
· Process parameters (e.g., power, gas flow) set for consistent treatment across variable geometries.
· Localized treatment is possible with minimal over treatment.
8. Portability and Integration
· Portable or handheld units available for field use (e.g., shipyards, depots, flightlines).
9. Safety and Compliance
· Equipped with built-in safety interlocks and meets relevant OSHA, NFPA, and MIL-STD safety standards.
10. Ease of Operation
· Intuitive interface with user selectable menu for multiple users.
· Minimal operator training required.
11. Repeatability and Documentation
· Provides repeatable and certifiable surface preparation process.
· Training and user manual provided.
12. Minimal Consumables
· Requires only industrial atmospheric air, no blasting media or fluids/chemicals.
· Low operating cost.
13. Portability
· Light weight allows for single-user carry and wide-ranging field applications
· Product must be no bigger than Size: 12” x 14” x 22” (31 x 36 x 56 cm) and/or18.1” x 17.5” x 8.2” (46 x 44.5 x 20.8 cm)
· Weight: no more than 41lbs
· Operating sound level: no higher than 90dBa
· Operating temperature no higher than 115 degrees
· Input power no higher than 208-240 VAC single-phase
· Perfect for tight spaces & remote locations; rugged design for industrial environment