Salient Characteristics- Redacted.doc
DOC document 78 KB Posted
- Attached to
- INTENT TO SOLE SOURCE - Starter-Generator System for Aviation Application Federal contract opportunity
- Solicitation number
- W911QX22Q0117
About this file
This federal contract opportunity announcement solicits proposals for a starter-generator system and associated components to meet requirements specified. The Army Research Laboratory requires two starter-generators capable of 7-10 kilowatts maximum power output, with a maximum specific power of 6 kilowatts per kilogram and continuous specific power of 3 kilowatts per kilogram. The solicitation also requires two inverters, two DC-DC converters, shipping, and technical support services. Proposals are due within 5 days of posting and the delivery date is 36 weeks after contract award. The solicitation is issued to ThinGap, Inc. as a sole source procurement conducted under FAR 6.302 with authority to award a contract to only this company.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combination Synopsis-Solicitation for Commercial Purchases.docx | DOCX document | |
| Provisions and Clauses Full-Text Attachment (for Combo Synopsis-Solicitation).doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): [REDACTED] The Army Research Laboratory requires the starter-generator system must meet the following minimum requirements:
Maximum power: Seven (7) to ten (10) kilowatts (kW)
Maximum specific power: six (6) kilowatts per kilogram (kW/kg)
Continuous specific power: three (3) kW/kg
Maximum speed: 20,000 Revolutions Per Minute (rpm)
Interface with a gearbox: axial flux design
Efficiency: 95 and above (95+) percentage (%)
Power in/out interface: 28 voltage direct current (VDC)
Starter-Generator dimension: 127 millimeter (mm) diameter x 177 millimeter (mm) length x 177 mm height
Inverter/controller weight: Four (4) to six (6) kilograms (kg)
Operating temperature: -48 to 49 deg Celsius (degC)
Starter-generator cooling method: air (forced)
Inverter/controller cooling method: air (forced)
Target maximum system weight: Nine (9) kg
The Contractor shall deliver two (2) starter-generators, two (2) chassis-cooled inverters, two (2) air-cooled direct current-direct current (DC-DC) converters and associated technical supports to the Government. The Contractor shall deliver the described items FOB Destination to Aberdeen Proving Ground, Maryland 21005.
| CLIN |
| CLIN Description |
| # of Units |
| Estimated Delivery Date |
| CLIN 0001 |
| TGD 127-98 Starter Generator housed with encoder |
| 2 |
| 36 Weeks After Contract Award (ACA) |
| CLIN 0002 |
| DC120A300VCS DRACO 120A, CAN/ chassis cooled, -40 TO +71, 300V |
| 2 |
| 36 Weeks ACA |
| CLIN 0003 |
| DC-DC converter prototype |
| 2 |
| 36 Weeks ACA |
| CLIN 0004 |
| Shipping cost |
| 2 |
| 36 Weeks ACA |
CLIN 0005
| Starter Generator technical supports (ThinGap) |
| 1 |
| 36 Weeks ACA |
CLIN 0006
| Inverter/controller and DC-DC converter technical supports (ESI Motion) |
| 1 |
| 36 Weeks ACA |
Technical Point of Contact (TPOC):
[REDACTED]
Contracting Officer:
Template last updated 01/8/2019